An experiment was carried out in a field in Husayniyah sub-district of the Holy Karbala Governorate. The research included studying the impact of the plowing depth and soil moisture on some technical indicators when using the disc plow. The 80 hp New Holland tractor was used in this experiment. Two factors were studied, the first factor is the soil moisture (12- 9%), (16-13%) and (20-17%) and the second factor was the depth of tillage (10-13) cm, (15-18) cm and (20-23) cm, which represented the secondary blocks. Bulk density, percentage of slippage and drawing force were studied. The field trials was conducted according to Split blocks in a randomized complete block design in three replicate. Consequences showed (according to the conditions of the experiment) that soil moisture of 17-20% outperformed in obtaining the lowest average bulk density of 1.25 g cm-3 whereas soil moisture of 12-9% recorded the lowest rate of slippage of 8.72% and the lowest rate of the net drawing of 1310.39 (kg.N). The plowing depth of 10-13 cm outperformed in obtaining the lowest average of bulk density of 1.25 g cm-3, the lowest slippage percentage of 7.19%, and the lowest rate of net drawing of 1013.84 (kg. N). The results also showed that soil moisture of 9-12% and plowing depth of 10-13 cm outperformed in obtaining the best interaction in most of the studied traits
In this study, a 3 mm thickness 7075-T6 aluminium alloy sheet was used in the friction stir welding process. Using the design of experiment to reduce the number of experiments and to obtain the optimum friction stir welding parameters by utilizing Taguchi technique based on the ultimate tensile test results. Orthogonal array of L9 (33) was used based on three numbers of the parameters and three levels for each parameter, where shoulder-workpiece interference depth (0.20, 0.25, and 0.3) mm, pin geometry (cylindrical thread flat end, cylindrical thread with 3 flat round end, cylindrical thread round end), and thread pitch (0.8, 1, and 1.2) mm) this technique executed by Minitab 17 software. The results showed th
... Show MoreThe complexity and partially defined nature of jet grouting make it hard to predict the performance of grouted piles. So the trials of cement injection at a location with similar soil properties as the erecting site are necessary to assess the performance of the grouted piles. Nevertheless, instead of executing trial-injected piles at the pilot site, which wastes money, time, and effort, the laboratory cement injection devices are essential alternatives for evaluating soil injection ability. This study assesses the performance of a low-pressure laboratory grouting device by improving loose sandy soil injected using binders formed of Silica Fume (SF) as a chemical admixture (10% of Ordinary Portland Cement OPC mass) to di
... Show MoreConcrete columns with hollow-core sections find widespread application owing to their excellent structural efficiency and efficient material utilization. However, corrosion poses a challenge in concrete buildings with steel reinforcement. This paper explores the possibility of using glass fiber-reinforced polymer (GFRP) reinforcement as a non-corrosive and economically viable substitute for steel reinforcement in short square hollow concrete columns. Twelve hollow short columns were meticulously prepared in the laboratory experiments and subjected to pure axial compressive loads until failure. All columns featured a hollow square section with exterior dimensions of (180 × 180) mm and 900 mm height. The columns were categorized into
... Show MoreThe blade pitch angle (BPA) in wind turbine (WT) is controlled to maximize output power generation above the rated wind speed (WS). In this paper, four types of controllers are suggested and compared for BPA controller in WT: PID controller (PIDC), type-1 fuzzy logic controller (T1-FLC), type-2 fuzzy logic controller (T2-FLC), and hybrid fuzzy-PID controller (FPIDC). The Mamdani and Sugeno fuzzy inference systems (FIS) have been compared to find the best inference system used in FLC. Genetic algorithm (GA) and Particle swarm optimization algorithm (PSO) are used to find the optimal tuning of the PID parameter. The results of500-kw horizontal-axis wind turbine show that PIDC based on PSO can reduced 2.81% in summation error of power
... Show MoreThis paper presents the implementation of a complex fractional order proportional integral derivative (CPID) and a real fractional order PID (RPID) controllers. The analysis and design of both controllers were carried out in a previous work done by the author, where the design specifications were classified into easy (case 1) and hard (case 2) design specifications. The main contribution of this paper is combining CRONE approximation and linear phase CRONE approximation to implement the CPID controller. The designed controllers-RPID and CPID-are implemented to control flowing water with low pressure circuit, which is a first order plus dead time system. Simulation results demonstrate that while the implemented RPID controller fails to stabi
... Show MoreMany economic entities working in multiple industrial fields suffer fromlow techniques in using modern administrative means in their works. The mostused tool in measuring required procedures is to adopt and use quality costs. inspite of complications and bronchial of operations in construction projects, Theresearcher was able to find a structure to quality costs according to traditionclassification (prevention, Appraisal, failure) which enables the calculation ofthese costs and then analyze results and setting standards which can beimplemented in evaluating strategic performance for targeted project. and theforge research in theoretical fly to quality and costs concerning it inconstruction section , as well as strategically performance a
... Show MoreIn this study the Entrance Surface Dose (ESD) received by pediatrics patients undergoing chest, abdomen and skull X-ray examinations was estimated. The study was conducted in two hospitals in Najaf city where three radiographic systems were considered. The study participants were classified into four age groups 0-1 , 1-5 , 5-10 and 10-15 years. Calculations were performed using exposure factors, kVp, mAs and focal-skin distance, together with patient data age. The ESD was calculated for the involved patients who underwent an Antero-posterior (AP) chest, abdomen and skull X-ray examination. The resulted data were analyzed and compared with international dose references. For all studied radiographic examinations and all X-ray mac
... Show More
Detection of virulence gene agglutinin-like sequence (ALS) 1 by using molecular technology from clinical samples (