Objective: Matrix tablet approach is one of the delivery systems intended for poorly water-soluble drugs, like candesartan cilexetil (CC). CC is a class II drug used for the treatment of hypertension. Methods: Matrix tablets from (F1x to F18z) were prepared in the presence of β‑cyclodextrin. Matrix tablet formulation ensures control release of the drug and higher dissolution by β‑cyclodextrin. Fourier transform infrared spectroscopy (FTIR), and differential scanning calorimetry (DSC) were used to study compatibility. Results: The angle of repose determination showed good flow for most of the formulas, besides having good compressibility. Weight variation test for all formulas showed accepted value. Drug content measurement showed accepted values. Friability and hardness of tablets were within the allowed values. Higher tablet swelling was obtained for the formulas containing hydroxypropyl methylcellulose (HPMC) K100M (F3x and F15z), in which the ratio of the polymer was 1:1 and 1:3, respectively. In vitro release showed that F1x to F13z were studied depends on the type and amount of polymer, i.e., 1:1, 1:2, and 1:3, respectively. F1x release after 8 hours was 95%, which contains 1:1 polymer ratio in comparison to F3x, which showed 85% after 8 hours, which includes 1:3 (drug: HPMC K100). Kinetic studies showed a zero-order model. Conclusion: The use of β‑cyclodextrin modifies the release profile of the drug, and some control the more sustained-release formulas. The lower the time of the release but in a range that a sustained release of the drug was observed in comparison with the formulas prepared without β‑cyclodextrin.
To study the comparative use of some soil minerals (zeolite, bentonite, phosphate rock, and limestone) in the adsorption and release of lead and its removal rates from its aqueous solutions using adsorption equations. Two laboratory experiments were carried out for the adsorption and release of lead. The adsorption experiment took 0.5 g of some of the above soil minerals. Lead was added as Pb (NO3)2 at levels of 3.0, 2.0, 1.5, 1.0, 0.5, and 0.0 mmol L-1 containing a concentration of 0.01M of calcium chloride. The experimental unit’s number was 72, the concentration of dissolved lead in the equilibrium solution was estimated and the amount of lead adsorbed was calculated. As for the lead release experiment, samples fo
... Show MoreThe population has been trying to use clean energy instead of combustion. The choice was to use liquefied petroleum gas (LPG) for domestic use, especially for cooking due to its advantages as a light gas, a lower cost, and clean energy. Residential complexes are supplied with liquefied petroleum gas for each housing unit, transported by pipes from LPG tanks to the equipment. This research aims to simulate the design and performance design of the LPG system in the building that is applied to a residential complex in Baghdad taken as a study case with eight buildings. The building has 11 floors, and each floor has four apartments. The design in this study has been done in two parts, part one is the design of an LPG system for one building, an
... Show MoreNaproxen is a non steroidal anti inflammatory and antipyretic drug which has local irritation effect on the stomach, and unpleasant taste, besides bad flowability and light sensitivity .The drug was prepared as microcapsules by complex coacervation method using acacia-gelatin coating materials , and aqueous colloid polymer dispersion method ( ACPD ), using ethyl cellulose and sodium alginate coating materials . The results indicated that microcapsules prepared by 2:1 core:wall ratio is the best for both methods, with an average encapsulation efficiency (75%) and avarege yield (90%) .
Moreover the drug release was affected mainly by core : ratio ,pH enviroment and method of microenca
... Show MoreBackground: Arylesterase activity of Paraoxonase-1 (ARE-PON-1) exhibits an antioxidant role which protects lipoprotein from oxidation. It is known that ARE-PON-1 antioxidant activity associated with high density lipoprotein cholesterol (HDL-C) reduces the oxidative damage mediated by low density lipoprotein cholesterol (LDL-C). The present study was aimed to examine the level of serum ARE-PON1 in Iraqi patients with β-thalassemia minor and its relationship with lipid profile (total cholesterol (TC), HDL-C, very low density lipoprotein (VLDL-C), and LDL-C) and hematologic changes as a part of antioxidant system action. Methods: In the present study, the ARE-PON-1 activity was investigated in serum of patients with β-thalassemia minor. Resu
... Show MoreOne hundred forty three of Klebsiellapneumoniae isolates had been collected from some hospitals in Baghdad city. The isolates were taken from different clinical specimens.Antimicrobial susceptibility test was carried out towards fifteen antimicrobial agents by using Vitek2 system with Antimicrobial susceptibility test cards. The results of antibiogram showed that the local isolates were possess highly resistance towards most antimicrobial agents under study. The high resistance wastoAmpicillin while the low resistance was to Imipenem.Two methods were used for detection of Extended Spectrum Beta Lactamases (ESBLs) production; first methods by using of Vitek2 system,thesecondmethods by using of polymerase chain reaction (PCR) technique to dis
... Show MoreObjective Thalassemic patients present with multiple immune abnormalities that may predispose them to oral Candida, however this has not been investigated. The aim of this study was to assess oral candidal colonization in a group of patients with β-thalassemia major both qualitatively and quantitatively. Study design The oral mycologic flora of 50 β-thalassemia major patients and 50 age- and sex-matched control subjects was assessed using the concentrated oral rinse technique. Candida species were identified using the germ tube test and the Vitek yeast identification system. Results Oral Candida was isolated from 37 patients (74%) and 28 healthy subjects (56%; P = .04). The mean candidal count was significantly higher in thalassemic patie
... Show MoreBackground: Esthetic treatment is the options of patient seeking orthodontic treatment. Therefore this study was conducted to measure the concentration of Aluminum, Nickel, Chromium and Iron ions released from combination of monocrysralline brackets with different arch wires immersed in artificial saliva at different duration, to evaluate the corrosion point on different parts of the orthodontic appliances before and after immersion in artificial saliva, and to evaluate the corrosion potential of each group of the orthodontic appliances. Material and methods: Eighty orthodontic sets prepared. Each set represents half fixed orthodontic appliance, from the central incisor to the first molar, for the maxillary arch, each set consisted of molar
... Show MoreCaptopril is an angiotensin converting enzyme inhibitor (ACEI) used to treat hypertension,
congestive heart failure, and myocardial infraction.
The only dosage form available for captopril is the plain tablet in strength of 12.5,25,50 and 100mg
tablet.
This investigation is concerned with factors affecting the formulation of captopril as a plain
tablet dosage form of 50mg. Many trials were made to prepare satisfactory tablets for the drug by
using wet – granulation methods with various additives. It was found that poly vinyl pyrrolidone
(P.V.P.) as binder gave the most satisfactory tablets. At the same time a shorter disintegrantion time
and slower dissolution rate were obtained with the addition of starch
Background: Metal ions can be released from metallic orthodontic appliances due to corrosion in the oral cavity; prophylactic mouthwashes may have an effect on ion release from orthodontic wires. Materials and Methods: Thirty six orthodontic sets of half maxillary fixed appliance with 2 types of arch wires SS and NiTi(Morelli) were constructed and immersed in 2 types of mouthwashes; Claradone (non-fluoridated) and Silver Care (fluoridated) for 28 days at 37°C, then the released Ni and Cr ionswere measured using atomic absorption spectrophotometer and compared statistically. Results: Ni ion release was higher from NiTi wire group than SS wire group for both mouthwashes and also was higher for Silver Care group than for Claradone group.
... Show More