General Directorate of Surveying is considered one of the most important sources of maps in Iraq. It produced digital maps for whole Iraq in the last six years. These maps are produced from different data sources with unknown accuracy; therefore, the quality of these maps needs to be assessed. The main aim of this study is to evaluate the positional accuracy of digital maps that produced from General Directorate of Surveying. Two different study areas were selected: AL-Rusafa and AL-Karkh in Baghdad / Iraq with an area of 172.826 and 135.106 square kilometers, respectively. Different statistical analyses were conducted to calculate the elements of positional accuracy assessment (mean µ, root mean square error RMSE, minimum and maximum errors). According to the obtained results, it can be stated that the maps of the General Directorate of Surveying can be used in reconnaissance or in works that require low or specified positional accuracy (eg. ±5m), and it cannot be used for applications need high accuracy (e.g. precise surveying).
The concerns about water contaminants affect most developing countries bypassing rivers over them. The issue is challenging to introduce water quality within the allowed limits for drinking, industrial and agricultural purposes. In the present study, physical-chemical parameters measurements of water samples taken from eleven stations were collected during six months in 2020 through flow path along the whole length of Tigris River inside AL Kut city (center of Wassit government) were investigated for six parameters are total hardness TH, hydrogen ion pH, biological oxygen demand BOD5, total dissolved solids TDS, nitrate NO3, and sulfate SO4. The water quality analysis results were compared with the maximum allowable limit concentrat
... Show MoreBackground: Moral distress, as one of the most important issues in the nursing profession, can negatively affect the healthcare system. Purpose: To examine the effect of moral distress on professional quality work life. Method: A descriptive cross-sectional study a non-probability sampling method used and total sample collected was (126) of ICU nurses. Results: Moral distress, BO, STS, and, CS among ICUs nurses were moderate. Conclusion: Nurses in ICUs suffered from moderate MD which that effected their BO and STS, and the result can be negative effects on quality of care. Although MD did not affect nurses' CS, it is still an important issue that nurses may face in ICUs
The objective of this research work is to evaluate the quality of central concrete plant of Al-Rasheed Company by using Six Sigma approach which is a measure of quality that strives for near elimination of defects using the statistical methods to improve outputs that are critical to customers. The fundamental objective of Six Sigma methodology is the implementation of a measurement-based strategy that focuses on process improvement and variation reduction to reach delighting customers, and then suggesting an improvement system to improve the production of concrete in Al-Rasheed State Contracting Construction Company.
A field survey includes two parts (open and close questionnaire) that aimed to get the data and information required f
This study aims to evaluate drinking water quality at the Al Wahda plant (WTP) in Baghdad city. A conventional water treatment plant with an average flow rate of 72.82 MLD. Water samples were taken from the influent and effluent of the treatment plant and analyzed for some physicochemical and biological parameters during the period from June to November 2020. The results of the evaluation indicate that treated water has almost the same characteristics as raw water; in other terms, the plant units do not remove pollutants as efficiently as intended. Based on this, the station appears to be nothing more than a series of water passage units. However, apart from Total dissolved solids, the mean values of all parameters in the study were
... Show MoreThis study aims to evaluate drinking water quality at the Al Wahda plant (WTP) in Baghdad city. A conventional water treatment plant with an average flow rate of 72.82 MLD. Water samples were taken from the influent and effluent of the treatment plant and analyzed for some physicochemical and biological parameters during the period from June to November 2020. The results of the evaluation indicate that treated water has almost the same characteristics as raw water; in other terms, the plant units do not remove pollutants as efficiently as intended. Based on this, the station appears to be nothing more than a series of water passage units. However, apart from Total dissolved solids, the mean values of all parameters in th
... Show More