The aim of this study is modeling the transport of industrial wastewater in sandy soil by using finite element method. A washing technique was used to remove the industrial wastewater from the soil. The washing technique applied with an efficient hydraulic gradient to help in transport of contaminant mass by advection. Also, the mass transport equation used in modeling the transport of industrial wastewater from soil includes the sorption and chemical reactions. The sandy soil samples obtained from Al-Najaf Governorate/Iraq. The wastewater contaminant was obtained from Al- Musyiebelectricity power plant. The soil samples were synthetically contaminated with four percentages of 10, 20, 30 and 40% of the contaminant and these percentages calculated from the distilled water used in the soaking process. The soaking process continued for 30 days. The contaminated soil samples were washed by using distilled water applied with a hydraulic gradient of 0.5. A laboratory physical model was designed to study the removal efficiency of contaminant from the soil after 10 days of remediation. The percentages of removal efficiency of the contaminant from the soil are (97.63, 96.79, 96.58, and 93.87) %. A computer program presented by Smith and Griffiths (P8.8) was developed bytaking into consideration both effects of adsorption and chemical reactions in solving mass transport equation. The results obtained from the developed computer program well agreed with those obtained experimentally in pattern and magnitudes. The effects of adsorption and chemical reactions are slight and have not effects on the quantity of contaminant mass transported by advection.
In this study the isomerization of desulfuerized light Iraqi petroleum naphtha (Al-Dura Refinery) with boiling point range of 37 to 124 °C , 80.5 API specific gravity and 68.2 octane number has been investigated. Two types of catalysts were prepared (Pt/HX and Pt/SrX) by impregnation of 0.8 wt% Pt on l 3X-zeolite. The catalyst activity and selectivity toward isomerization, and catalyst deactivation were investigated.
The isomerization unit consisted of a vertical tubular stainless steel reactor of 2 cm internal diameter, 3 cm external diameter and 68 cm height. The operating pressure was atmospheric for all experimental runs. The liquid flow of lightnaphtha was 0.4 Uh, and the catalyst weight was 50 gm, H/
... Show MoreIn this paper a nonlinear adaptive control method is presented for a pH process, which is difficult to control due to the nonlinear and uncertainties. A theoretical and experimental investigation was conducted of the dynamic behavior of neutralization process in a continuous stirred tank reactor (CSTR). The process control was implemented using different control strategies, velocity form of PI control and nonlinear adaptive control. Through simulation studies it has been shown that the estimated parameters are in good agreement with the actual values and that the proposed adaptive controller has excellent tracking and regulation performance.
Process capability provides a quantitative measure for gasoline production conformance to specifications.It was measured throughout four consecutive months of the last quarter of 2011. Results revealed high percentages (up to 44%) of non conforming gasoline blends to Iraqi marketing specifications for petroleum products (2000) by inspecting 122 different samples of Iraqi regular gasoline (RON 85).
Quality cost analysis as an important financial control tool was carried out to evaluate Cost of Quality (COQ) which was large due to non conforming gasoline reached up to (722.8 M.ID) in October. In this research COQ was investigated in order to identify the opportunities of gasoline quality improvements through production process. Also cus
The production of polyhydroxyalkanoates PHAs from biopolymer degrading bacteria was examined
The banking industry, as a result of the great challenges it faced, required continuous development of the principles of management, control and mechanisms used. The Basel Committee on Banking Supervision has played a leading role in legalizing many of these developments and has been able to contribute significantly to establishing a common framework for banking supervision, The central role in the various countries of the world is based on coordination between the various regulatory authorities and thinking about finding mechanisms to confront the risks faced by banks, recognizing the importance of the banking sector in the stability of domestic and international banking systems or the danger of this sector in the emergence of F
... Show MoreAs a result of industrial development, many types of waste are generated, some of which are discharged into water, causing water pollution and having a negative impact on life. The electro-Fenton process (EF) has verified high efficiency in treating pollutants with low cost, ease of handling and operation, and this technology is one of the more efficient advanced oxidation technologies. The main objective of this present work is to explore the efficiency of a three-dimensional Electro-Fenton system (3DEF) in removing eosin, methylene blue, and methylene violet from simulated wastewater using graphite as anode, nickel foam as the cathode, and alum sludge as the third particle and as the source of catalyst. The study investigated the effect o
... Show More