Preferred Language
Articles
/
u4art4YBIXToZYALlLOg
Static Shear Strength of a Non-Prismatic Beam with Transverse Openings
...Show More Authors

In this study, a predicated formula is been proposed to find the shear strength of non-prismatic beams with or without openings. It depends on the contributions of concrete shear strength considering the beam depth variation and existing openings, shear steel reinforcements and defines the critical shear section, the effect of diagonal shear reinforcement, the effect of inclined tensile steel reinforcement, and the compression chord influence. The verification of the proposed formula has been conducted on the experimental test results of 26 non-prismatic beams with or without openings at the same loading conditions. The results reflect that the predicted formula finds the shear capacity of non-prismatic beams with openings, it is conservative and can be used for designing without the strength reduction factor.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Nov 02 2020
Journal Name
International Journal Of Pharmaceutical Research
Serum Afamin As A Novel Biomarker for Non-Alcoholic Fatty Liver Disease as A Complication of Hypothyroidism in Iraqi Patients.
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sat Dec 31 2016
Journal Name
Al-kindy College Medical Journal
Non Traumatic Hip Osteonecrosis Treated By Non Vascularised Bone Graft Versus Core Decompression
...Show More Authors

Background: Avascular necrosis (AVN) is defined as cellular death of bone components due to interruption of the blood supply; the bone structures then collapse, resulting in bone destruction, pain, and loss of joint function. AVN is associated with numerous conditions and usually involves the epiphysis of long bones, such as the femoral head. In clinical practice, AVN is most commonly encountered in the hip. Early diagnosis and appropriate intervention can delay the need for joint replacement. However, most patients present late in the disease course. Without treatment, the process is almost always progressive, leading to joint destruction within 5 years.Treatment of a vascular necrosis depends mainly on early diagnosis which mainly base

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Apr 13 2022
Journal Name
International Journal Of Medical Sciences
Evaluation of the Levels of Erythropoietin and Some Haehematological Parameters in Patients with History of Haemodialysis and Non- haemodialysis
...Show More Authors

Publication Date
Wed Dec 20 2023
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Systemic Melatonin Supplementation as an Adjunct to Non-Surgical Periodontal Treatment in Obese Patients with Periodontitis
...Show More Authors

Background: Obesity is considered an important risk factor for periodontal disease. It has been reported that reactive oxygen species linking both diseases, systemic melatonin supplementation as antioxidant therapy, was addressed as an adjuvant to scaling and root surface debridement (SRP) to enhance the treatment of periodontitis. Objective: To investigate the efficacy of systemic melatonin administration in periodontitis-obese patients as an adjuvant to scaling and root surface debridement (SRP). Methods: A randomized clinical trial was conducted at a dental-specialized center. Eighty subjects were included and allocated into group-I: twenty periodontium-healthy, normal-weight people; group-II: 30 obese patients with stage-III tre

... Show More
View Publication
Scopus Crossref
Publication Date
Fri Jun 01 2012
Journal Name
Karbala J. Med
Non Vascularized Bone Graft versus Core Decompression in Treatment of Early Stages of Non Traumatic Hip Osteonecrosis
...Show More Authors

A vascular necrosis (AVN) is defined as cellular death of bone components due to interruption of the blood supply; the bone structures then collapse, resulting in bone destruction, pain, and loss of joint function. AVN is associated with numerous conditions and usually involves the epiphysis of long bones, such as the femoral head. In clinical practice, AVN is most commonly encountered in the hip. Early diagnosis and appropriate intervention can delay the need for joint replacement. However, most patients present late in the disease course. Without treatment, the process is almost always progressive, leading to joint destruction within 5 years. Treatment of a vascular necrosis depends mainly on early diagnosis which mainly based on clinical

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 01 2021
Journal Name
Journal Of Engineering Science And Technologythis Link Is Disabled
Cfd simulation for the operation effect of gates openings of al-hay regulator on the local erosion
...Show More Authors

Scopus (6)
Scopus
Publication Date
Wed Sep 16 2020
Journal Name
International Journal Of Dentistry And Oral Science
Attitude and Knowledge of Orthodontics among General Dentists and Non-Orthodontic Specialists: A Questionnaire Based Survey
...Show More Authors

Aim: This study aimed to assessing orthodontic knowledge and attitude among general dentists and non-orthodontic specialists. Background: Early detection of orthodontic disorders is essentialin motivating patients to intervene prior to long term complications when the disorders are not recongised. Methods: A questionnaire was distributed amongst dentistsother than orthodontists. This questionnaire consisted of three sections. The first one aimed to collect demographic, educational level and practice type information. Further two sections consisted of closed-end questions designed to evaluateknowledge and attitude of orthodontics. Results: A total of 313 responses to the survey were submitted. No significant correlation was observed, e

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Thu May 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Numerical Study of Crack Effect on Frequency of Simple Supported Beam
...Show More Authors

In this research the natural frequency of a cracked simple supported beam (the crack is in many places and in different depths) is investigated analytically, experimentally and numerically by ANSYS program, and the results are compared. The beam is made of iron with dimensions of L*W*H= (0.84*0.02* 0.02m), and density = 7680kg/m3, E=200Gpa. A comparison made between analytical results from ANSYS with experimental results, where the biggest error percentage is about (7.2 %) in crack position (42 cm) and (6 mm) depth. Between Rayleigh method with experimental results the biggest error percentage is about (6.4 %) for the same crack position and depth. From the error percentages it could be concluded that the Rayleigh method gives

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 25 2017
Journal Name
Al-khwarizmi Engineering Journal
Prediction of Oxygen Mass Transfer Coefficients in Stirred Bioreactor with Rushton Turbine Impeller for Simulated (Non-Microbial) Medias
...Show More Authors

 Abstract

The study of oxygen mass transfer was conducted in a laboratory scale 5 liter stirred bioreactor equipped with one Rushton turbine impeller. The effects of superficial gas velocity, impeller speed, power input and liquid viscosity on the oxygen mass transfer were considered. Air/ water and air/CMC systems were used as a liquid media for this study. The concentration of CMC was ranging from 0.5 to 3 w/v. The experimental results show that volumetric oxygen mass transfer coefficient increases with the increase in the superficial gas velocity and impeller speed and decreases with increasing liquid viscosity. The experimental results of kla were correlated with a mathematical correlation des

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 05 2022
Journal Name
Mathematical Methods In The Applied Sciences
Double‐diffusive convection on peristaltic flow of hyperbolic tangent nanofluid in non‐uniform channel with induced magnetic field
...Show More Authors

Consequence of thermal and concentration convection on peristaltic pumping of hyperbolic tangent nanofluid in a non‐uniform channel and induced magnetic field is discussed in this article. The brief mathematical modeling, along with induced magnetic field, of hyperbolic tangent nanofluid is given. The governing equations are reduced to dimensionless form by using appropriate transformations. Exact solutions are calculated for temperature, nanoparticle volume fraction, and concentration. Numerical technique is manipulated to solve the highly non‐linear differential equations. The roll of different variables is graphically analyzed in terms of concentration, temperature, volume fraction of nanoparticles, axial induced magnetic fie

... Show More
View Publication
Scopus (20)
Crossref (18)
Scopus Clarivate Crossref