Preferred Language
Articles
/
txcJ8pEBVTCNdQwC75yW
Zinc (II) removal from simulated wastewater by electro-membrane extraction approach: Adopting an electrolysis cell with a flat sheet supported liquid membrane
...Show More Authors

The aim of this study is to utilize the electromembrane extraction (EME) system as a manner for effective removal of zinc from aqueous solutions. A novel and distinctive electrochemical cell design was adopted consisting of two glass chambers, a supported liquid membrane (SLM) housing a polypropylene flat membrane infused with 1-octanol and a carrier. Two electrodes were used, a graphite as anode and a stainless steel as cathode. A comprehensive examination of several influential factors including the choice of carrier, the applied voltage magnitude, the initial pH of the donor solution, and the initial concentration of zinc was performed, all in a concerted effort to ascertain their respective impacts on the efficiency of zinc elimination. Two distinct carriers, namely tris(2-ethylhexyl) phosphate (TEHP) and bis(2-ethylhexyl) phosphate (DEHP) were evaluated, in a tandem with utilization of 1-octanol. The results revealed essential role played by the applied voltage in augmenting the rate of mass transfer of zinc across the membrane. The best operating conditions were utilized for 1-octanol enriched with 1.0 vol.% bis(2-ethylhexyl) phosphate as a carrier, applied voltage of 60 V, initial pH of 5, initial zinc concentration of 15 mg L-1, extraction duration of 6 hours, and stirring rate of 1000 rpm. Surprisingly, operating under these meticulously devised conditions culminated in the outstanding removal efficiency of 87.3 %. In comparison with no applied voltage, a substantial enhancement in removal efficiency was observed, trans­cending from a meager 36.67 % to an impressive 87.3 % at 60 V, suggesting thus a tremen­dous potential of EME as an efficacious technique for the elimination of heavy metals.

Scopus Clarivate Crossref
View Publication
Publication Date
Fri May 01 2020
Journal Name
Journal Of Engineering
Removal of Acidic Dye from Aqueous Solution Using Surfactant Modified Bentonite (Organoclay): Batch and Kinetic Study
...Show More Authors

Modified bentonite has been used as effective sorbent material for the removal of acidic dye (methyl orange) from aqueous solution in batch system. The natural bentonite has been modified using cationic surfactant (cetyltrimethyl ammonium bromide) in order to obtain an efficient sorbent through converting the properties of bentonite from hydrophilic to organophilic. The characteristics of the natural and modified bentonite were examined through several analyses such as Scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), and Surface area. The batch study was provided the maximum dye removal efficiency of 88.75 % with a sorption capacity of 555.56 mg/g at specified conditions (150 min, pH= 2, 250 rpm, and 0.

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sat Feb 01 2020
Journal Name
Journal Of Water Process Engineering
Predominant mechanisms for the removal of nickel metal ion from aqueous solution using cement kiln dust
...Show More Authors

Scopus (59)
Crossref (43)
Scopus Clarivate Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Journal Of Ecological Engineering
Dual Application of Al-Kheriat of Removal of Arsenic from Aqueous Solution and Acting as Rodenticide
...Show More Authors

Arsenic is a prevalent and pervasive environmental contaminant with varied amounts in drinking water. Arsenic exposure causes cancer, cardiovascular, liver, nerve, and ophthalmic diseases. The current study aimed to find the best conditions for eliminating arsenic from simulated wastewater and their effect on biomarkers of hepatic in mice. Adsorption tests including pH, contact duration, Al-kheriat dosage, and arsenic concentrations were evaluated. Seventy-two healthy albino mice (male) were accidentally allocated into nine groups (n = 8), the first group was considered as healthy control, the second group (AL-Kheriat), and other groups received AL-Kheriat and arsenic 25, 50, 75, 100, 125, 150 and 175 mg/kg, respectively. Next 10 days, the

... Show More
Crossref (3)
Crossref
Publication Date
Sat Feb 01 2020
Journal Name
Journal Of Water Process Engineering
Waterworks sludge-filter sand permeable reactive barrier for removal of toxic lead ions from contaminated groundwater
...Show More Authors

Scopus (213)
Crossref (192)
Scopus Clarivate Crossref
Publication Date
Wed Sep 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Free Convection in an Inclined Concentric Annular Square Cavities Filled With Porous Medium and Heated By Non-Uniform Temperature
...Show More Authors

A numerical study of the two-dimensional steady free convection flow in an inclined annulus between two concentric square cavities filled with a porous medium is presented in this paper for the case when the side outer walls are kept with differentially heated temperature while the horizontal outer walls and the inner walls are insulated. The heated wall is assumed to have spatial sinusoidal temperature variation about a constant mean value. The Darcy model is used and the fluid is assumed to be a standard Boussinesq fluid. For the Cartesian coordinate system, the governing equations which were used in stream function form are discretized by using the finite difference method with successive under – relaxation method (SUR) and are solv

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Agricultural Engineering
Evaluation of Flat Fan Nozzles Operating Parameters Under Conditions of Accelerated Boundary and Destructive Wear
...Show More Authors
Abstract<p>Two tests were carried out to measure the standard flat fan nozzles wear during a specific period of an accelerated wear procedure. The first test aimed at getting 10% increase in the flow rate compared to the nominal flow rate, which is the threshold to replace the nozzles according to the nozzles testing standards. The second test was to wear the nozzles intensively (100 hours of accelerated wear), which represents the use of nozzles beyond the allowed threshold. The results showed that the flow rate reached 1.31 l·min<sup>−1</sup> (equal to 10% increase) for the tested nozzles after 35 hours of the wear test. For the second test, the 10% increase of the flow rate was r</p> ... Show More
Crossref (1)
Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Manufacturing and Study the performance of Selective Surfaces that used in flat plate Solar Collectors
...Show More Authors

In this research an experimental study has done for testing the thermal performance of selective surfaces used in solar collectors for substrate of iron, galvanized iron and aluminum which are commercially available. The coating process for the samples has done in two ways, the electroplating and the chemical spray pyrolysis. The results of the thermal performance test of these samples are comparing with the thermal performance of a sample without paint and other paint with black paint without shines commercially available. For the electroplated samples, the performance study has done for different immersion time in plating bath, the
distance between electrical poles, the current density, and area ratio of the sample plated area to

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Oct 01 2021
Journal Name
Civil Engineering Journal
Steel Fiber Enhancement upon Punching Shear Strength of Concrete Flat Plates Exposed to Fire Flame
...Show More Authors

In this study, the effect of fire flame on the punching shear strength of steel fiber reinforced concrete flat plates was experimentally investigated using nine half-scale specimens with dimensions of 1500×1500 mm and a total thickness of 100 mm. The main investigated variables comprised the steel fiber volume fraction 0, 1, and 1.5% and the burning steady state temperature 500 and 600 °C. The specimens were divided into three groups, each group consists of three specimens. The specimens in the first group were tested with no fire effect to be the reference specimens, while the others of the second and third groups were tested after being exposed to fire-flame effect. The adopted characteristics of the fire test were; (one hour) b

... Show More
Crossref (3)
Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector
...Show More Authors

Abstract

    In order to enhance the efficiency of flat plate solar water collectors without changing in its original shape and with low additional cost, twisted strips are inserted inside its riser pipes. Three flat plate collectors are used for test. Family of twisted strips are inserted inside each collector risers with different twisted ratios (TR=3,4,5). The collectors are connected in parallel mode (Z-Configuration) and are exposed to the same conditions (solar radiation and ambient temperature) .The experimental results show that, the highest heat transfer rate occurs at twisted ratio (3) .Consequently, for the same twisted ratio the daily efficiencies for the solar collector at d

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 13 2012
Journal Name
Wireless Personal Communications
Design and Implementation of a Scalable RFID-Based Attendance System with an Intelligent Scheduling Technique
...Show More Authors

View Publication
Scopus (17)
Crossref (7)
Scopus Clarivate Crossref