The development of a reversed phase high performance liquid chromatography fluorescence method for the determination of the mycotoxins fumonisin B1 and fumonisin B2 by using silica-based monolithic column is described. The samples were first extracted using acetonitrile:water (50:50, v/v) and purified by using a C18 solid phase extraction-based clean-up column. Then, pre-column derivatization for the analyte using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol was carried out. The developed method involved optimization of mobile phase composition using methanol and phosphate buffer, injection volume, temperature and flow rate. The liquid chromatographic separation was performed using a reversed phase Chromolith® RP-18e column (100 mm × 4.6 mm) at 30 °C and eluted with a mobile phase of a mixture of methanol and phosphate buffer pH 3.35 (78:22, v/v) at a flow rate of 1.0 mL min−1. The fumonisins separation was achieved in about 4 min, compared to approximately 20 min by using a C18 particle-packed column. The fluorescence excitation and emission were at 335 nm and 440 nm, respectively. The limits of detections were 0.01–0.04 μg g−1 fumonisin B1 and fumonisin B2, respectively. Good recoveries were found for spiked samples (0.1, 0.5, 1.5 μg g−1 fumonisins B1 and B2), ranging from 84.0 to 106.0% for fumonisin B1 and from 81.0 to 103.0% for fumonisin B2. Fifty-three samples were analyzed including 39 food and feeds and 14 inoculated corn and rice. Results show that 12.8% of the food and feed samples were contaminated with fumonisin B1 (range, 0.01–0.51 μg g−1) and fumonisin B2 (0.05 μg g−1). The total fumonisins in these samples however, do not exceed the legal limits established by the European Union of 0.8 μg g−1. Of the 14 inoculated samples, 57.1% contained fumonisin B1 (0.16–41.0 μg g−1) and fumonisin B2 (range, 0.22–50.0 μg g−1). Positive confirmation of selected samples was carried out using liquid chromatography–tandem mass spectrometry, using triple quadrupole analyzer and operated in the multiple reaction monitoring mode.
The morphological and histological aspects of fore brain (Cerebrum) in quail (Coturnix coturnix) have been investigated, results of the present study revealed that the cerebrum in quail is large size triangular shape, its surface contains folds of shallow grooves. Microscopical examination declears that cerebrum consists of two regions, the first represents pallium which includes the external corticoid area which consist of hyperpallium and the dorsolateral corticoid area, it consists of piriform cortex and hippocampal complex. The second region is the internal corticoid areas dorsal ventricular ridge which contains the mesopallium, nidopallium and archopallium. he large size pyramidal neurons appeared in the nidopall
... Show MoreBackground: Chronic suppurative otitis media (CSOM) is the result of aninitial episode of acute otitis media and is characterized by a persistent discharge from the middle ear through a tympanic perforation for at least 2 weeks duration. It is an important cause of preventable hearing loss, particularly in the developing world.Methods. 1. To get an overview on the bacterial ear infection profile in general 2. To assess the antibiotic resistance of Pseudomonal infection (PS) particularly since it is usually the commonest infection to cause otitis media and the most difficult to treat due to the problem of multi drug resistance... A cross sectional study was done which included 405 patient of CSOM patients196 (48%) case were males ,209 (52
... Show MoreBackground: Primary healthcare in Egypt has undergone significant reforms since the 1990s, including the pioneering Family Health Program (FHP). However, limited evaluation exists regarding the FHP's impact on enhancing the delivery of primary healthcare services. The primary objective of this study was to analyze and understand the efficiency and effectiveness of the FHP in altering the delivery of primary healthcare in Egypt. We aimed to outline the fundamental characteristics of the primary healthcare system, compare them between the conventional and the newly reformed FHP centers, and gauge the awareness level of these variances among key decision-makers, focusing specifically on Cairo, Egypt. Methods: This cross-sectional study employe
... Show MoreThe aggregation capacity of human reb blood cells lies between that of the non- aggregated arythrocyte and the remarkably full sedimentation. As the ability to aggregate is atributed to many factors such as the availability of macromolecules and plasma lipids, the role of plasm lipid profile on RBC aggregation and sedimentation changes in normal and diabetic patients is studied.Also serum lipid profile measurement (Total cholesterol, Triglyceride, HDL, LDL, VLDL) in normal and diabetic subjects were made. The principle of measurement includes detecting the transmitted laser light through a suspension of 10% diluted red blood cells in plasma. In all diabetics, the raulux formation and sedimentation rate is enhanced.
One of the goals of adding adjuvants to agricultural spray solutions is to enhance the droplet size characteristics of this spray. Droplet size, in turn, has an influence in the deposited spray quality, in addition to the drift and losses of spray to off-target places. The aim of this research was to evaluate the effect of adding adjuvants to two types of water from different sources on the droplet size characteristics. Two types of adjuvants were employed in the tests: the active substance content of the first adjuvant was a 50% aqueous solution of sodium salt of alkylbenzenesulfonic acid—10% (HY), whereas the second was from rapeseed oil (natural origin)—85% (OL). Both adjuvants were tested in two concentrations: the first was
... Show MoreTo determine the relationship between chronic hepatitis B virus and autoimmune celiac disease, seventy five patients with chronic hepatitis B virus of ages (8-70) years have been investigated and compared with 50 healthy individuals. All the studied groups were carried out to measure antiGliadin antibodies IgA and IgG by ELISA test and anti-reticulin antibodies IgA and IgG by IFAT. There were significant elevation (P<0.05) in the concentration of AGA IgA and IgG antibodies compared to control group. The prevalence of AGA antibodies IgA and IgG was 8% and 9.33% respectively. There were a highly significant differences (P<0.01) between studies groups. The prevalence of antireticulin antibodies ARA IgA and IgG was 6.67% and 4.0% respectively i
... Show More