Preferred Language
Articles
/
thaz3osBVTCNdQwCcuKW
A reversed phase high performance liquid chromatography method for the determination of fumonisins B1 and B2 in food and feed using monolithic column and positive confirmation by liquid chromatography/tandem mass spectrometry
...Show More Authors

The development of a reversed phase high performance liquid chromatography fluorescence method for the determination of the mycotoxins fumonisin B1 and fumonisin B2 by using silica-based monolithic column is described. The samples were first extracted using acetonitrile:water (50:50, v/v) and purified by using a C18 solid phase extraction-based clean-up column. Then, pre-column derivatization for the analyte using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol was carried out. The developed method involved optimization of mobile phase composition using methanol and phosphate buffer, injection volume, temperature and flow rate. The liquid chromatographic separation was performed using a reversed phase Chromolith® RP-18e column (100 mm × 4.6 mm) at 30 °C and eluted with a mobile phase of a mixture of methanol and phosphate buffer pH 3.35 (78:22, v/v) at a flow rate of 1.0 mL min−1. The fumonisins separation was achieved in about 4 min, compared to approximately 20 min by using a C18 particle-packed column. The fluorescence excitation and emission were at 335 nm and 440 nm, respectively. The limits of detections were 0.01–0.04 μg g−1 fumonisin B1 and fumonisin B2, respectively. Good recoveries were found for spiked samples (0.1, 0.5, 1.5 μg g−1 fumonisins B1 and B2), ranging from 84.0 to 106.0% for fumonisin B1 and from 81.0 to 103.0% for fumonisin B2. Fifty-three samples were analyzed including 39 food and feeds and 14 inoculated corn and rice. Results show that 12.8% of the food and feed samples were contaminated with fumonisin B1 (range, 0.01–0.51 μg g−1) and fumonisin B2 (0.05 μg g−1). The total fumonisins in these samples however, do not exceed the legal limits established by the European Union of 0.8 μg g−1. Of the 14 inoculated samples, 57.1% contained fumonisin B1 (0.16–41.0 μg g−1) and fumonisin B2 (range, 0.22–50.0 μg g−1). Positive confirmation of selected samples was carried out using liquid chromatography–tandem mass spectrometry, using triple quadrupole analyzer and operated in the multiple reaction monitoring mode.

Scopus Clarivate Crossref
View Publication
Publication Date
Mon Sep 15 2014
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Simultaneous Determination of Ciprofloxacin Hydrochloride and Mebeverin Hydrochloride by Derivative Spectrophotometry
...Show More Authors

A new Spectrophotometric method, is for individual and simultaneous determination of Ciprofloxacin hydrochloride(CIP) and Mebeverin hydrochloride(MEB) by the first and second derivative mode techniques. The first and second derivative spectra of these compounds permitted individual and simultaneous determination of CIP and MEB in concentration range of (4-28μg/mL) by measuring the amplitude of peak- to- base line and the area under peak at selected spectrum intervals. The methods showed a reasonable precision and accuracy and have been applied to determine CIP and MEB in four different pharmaceutical preparations.

Preview PDF
Publication Date
Wed May 10 2023
Journal Name
International Journal Of Emerging Technologies In Learning
The Effect of Cognitive Modeling in Mathematics Achievement and Creative Intelligence for High School Students
...Show More Authors

Scopus (8)
Scopus
Publication Date
Sat Apr 12 2025
Journal Name
Mustansiriyah Journal Of Sports Science
A Review of the Use of Artificial Intelligence Algorithms for Predicting Injuries and Performance in Football Players
...Show More Authors

The purpose of this study is to investigate the research on artificial intelligence algorithms in football, specifically in relation to player performance prediction and injury prevention. To accomplish this goal, scholarly resources including Google Scholar, ResearchGate, Springer, and Scopus were used to provide a systematic examination of research done during the last ten years (2015–2025). Through a systematic procedure that included data collection, study selection based on predetermined criteria, categorisation based on AI applications in football, and assessment of major research problems, trends, and prospects, almost fifty papers were found and analysed. Summarising AI applications in football for performance and injury p

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Thu Feb 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Comparison of Slice inverse regression with the principal components in reducing high-dimensions data by using simulation
...Show More Authors

This research aims to study the methods of reduction of dimensions that overcome the problem curse of dimensionality when traditional methods fail to provide a good estimation of the parameters So this problem must be dealt with directly . Two methods were used to solve the problem of high dimensional data, The first method is the non-classical method Slice inverse regression ( SIR ) method and the proposed weight standard Sir (WSIR) method and principal components (PCA) which is the general method used in reducing dimensions,    (SIR ) and (PCA) is based on the work of linear combinations of a subset of the original explanatory variables, which may suffer from the problem of heterogeneity and the problem of linear

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Nov 23 2017
Journal Name
Brazilian Journal Of Analytical Chemistry
Microvolume-DLLME for the Spectrophotometric Determination of Clidinium Bromide in Drug, Urine, and Serum
...Show More Authors

The present study combines UV-Vis spectrophotometry and dispersive liquid-liquid microextraction (DLLME) for the preconcentration and determination of trace level clidinium bromide (Clid) in pharmaceutical preparation and real samples. The method is based on ion-pair formation between Clid and bromocresol green in aqueous solution using citrate buffer (pH = 3). The colored product was first extracted using a mixture of 800 µL acetonitrile and 300 µL chloroform solvents. Then, a spectrophotometric measurement of sediment phase was performed at λ = 420 nm. The important parameters affecting the efficiency of DLLME were optimized. Under the optimum conditions, the calibration graphs of standard -1 (Std.), drug, urine and serum were ranged

... Show More
Scopus (5)
Scopus
Publication Date
Wed Feb 22 2023
Journal Name
Iraqi Journal Of Science
Spectrophotometric Kinetic Methods for the Determination of Paracetamol in Pure Form and Pharmaceutical Preparations
...Show More Authors

Simple and sensitive kinetic methods are developed for the determination of Paracetamol in pure form and in pharmaceutical preparations. The methods are based on direct reaction (oxidative-coupling reaction) of Paracetamol with o-cresol in the presence of sodium periodate in alkaline medium, to form an intense blue-water-soluble dye that is stable at room temperature, and was followed spectrophotometriclly at λmax= 612 nm. The reaction was studied kinetically by Initial rate and fixed time (at 25 minutes) methods, and the optimization of conditions were fixed. The calibration graphs for drug determination were linear in the concentration ranges (1-7 μg.ml-1) for the initial rate and (1-10 μg.ml-1) for the fixed time methods at 25 min.

... Show More
View Publication Preview PDF
Publication Date
Mon May 31 2021
Journal Name
Indian Journal Of Ecology
Identification and Antimicrobial Susceptibility Profiles of Salmonella spp. Isolated from Chicken Flocks and their Feed and Water in Karbala, Iraq
...Show More Authors

The objective of study was determining the most prevalent Salmonella spp. and their antimicrobial susceptibility in broilers and laying chickens and their feed and drinking water in five chicken farms in Karbala, Iraq over the period from August to October 2020. A total of 289 samples, including 217 cloaca swabs, 46 water and 26 feed samples were collected. Salmonella spp. was identified firstly by routine diagnostic methods, followed by applying the API 20E kit, the Vitek2 system, and serology. There was significant differences in Salmonella prevalence among different types of samples, mainly cloaca swabs reported a high isolation rate (21.7%). In contrast, feed samples were completely free of contamination. The highest rate of isolation w

... Show More
Preview PDF
Publication Date
Fri Apr 21 2023
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees22fr
Study of the x-ray diffraction lines of calcium titanate nanoparticle using SSP method and Scherrer method
...Show More Authors

In this study, the modified size-strain plot (SSP) method was used to analyze the x-ray diffraction lines pattern of diffraction lines (1 0 1), (1 2 1), (2 0 2), (0 4 2), (2 4 2) for the calcium titanate(CaTiO3) nanoparticles, and to calculate lattice strain, crystallite size, stress, and energy density, using three models: uniform (USDM). With a lattice strain of (2.147201889), a stress of (0.267452615X10), and an energy density of (2.900651X10-3 KJ/m3), the crystallite was 32.29477611 nm in size, and to calculate lattice strain of Scherrer (4.1644598X10−3), and (1.509066023X10−6 KJ/m3), a stress of(6.403949183X10−4MPa) and (26.019894 nm).

View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Tue Mar 05 2024
Journal Name
Scientific Reports
Mesoporous Ag@WO3 core–shell, an investigation at different concentrated environment employing laser ablation in liquid
...Show More Authors
Abstract<p>In this study, silver-tungsten oxide core–shell nanoparticles (Ag–WO<sub>3</sub> NPs) were synthesized by pulsed laser ablation in liquid employing a (1.06 µm) Q-switched Nd:YAG laser, at different Ag colloidal concentration environment (different core concentration). The produced Ag–WO<sub>3</sub> core–shell NPs were subjected to characterization using UV–visible spectrophotometry, X-ray diffraction (XRD), transmission electron microscopy (TEM), energy-dispersive spectroscopy, electrical analysis, and photoluminescence PL. The UV–visible spectra exhibited distinct absorption peaks at around 200 and 405 nm, which attributed to the occurrence of surface Plasmon reson</p> ... Show More
View Publication
Scopus (18)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Thu Jan 01 2015
Journal Name
International Journal Of Optics And Applications
Modeling and Analysis of a Miniaturized Ring Modulator Using Silicon-Polymer-Metal Hybrid Plasmonic Phase Shifter. Part I: Theoretical Framework
...Show More Authors

This paper presents comprehensive analysis and investigation for 1550nm and 1310nm ring optical modulators employing an electro-optic polymer infiltrated silicon-plasmonic hybrid phase shifter. The paper falls into two parts which introduce a theoretical modeling framework and performance assessment of these advanced modulators, respectively. In this part, analytical expressions are derived to characterize the coupling effect in the hybrid phase shifter, transmission function of the modulator, and modulator performance parameters. The results can be used as a guideline to design compact and wideband optical modulators using plasmonic technology

View Publication