The development of a reversed phase high performance liquid chromatography fluorescence method for the determination of the mycotoxins fumonisin B1 and fumonisin B2 by using silica-based monolithic column is described. The samples were first extracted using acetonitrile:water (50:50, v/v) and purified by using a C18 solid phase extraction-based clean-up column. Then, pre-column derivatization for the analyte using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol was carried out. The developed method involved optimization of mobile phase composition using methanol and phosphate buffer, injection volume, temperature and flow rate. The liquid chromatographic separation was performed using a reversed phase Chromolith® RP-18e column (100 mm × 4.6 mm) at 30 °C and eluted with a mobile phase of a mixture of methanol and phosphate buffer pH 3.35 (78:22, v/v) at a flow rate of 1.0 mL min−1. The fumonisins separation was achieved in about 4 min, compared to approximately 20 min by using a C18 particle-packed column. The fluorescence excitation and emission were at 335 nm and 440 nm, respectively. The limits of detections were 0.01–0.04 μg g−1 fumonisin B1 and fumonisin B2, respectively. Good recoveries were found for spiked samples (0.1, 0.5, 1.5 μg g−1 fumonisins B1 and B2), ranging from 84.0 to 106.0% for fumonisin B1 and from 81.0 to 103.0% for fumonisin B2. Fifty-three samples were analyzed including 39 food and feeds and 14 inoculated corn and rice. Results show that 12.8% of the food and feed samples were contaminated with fumonisin B1 (range, 0.01–0.51 μg g−1) and fumonisin B2 (0.05 μg g−1). The total fumonisins in these samples however, do not exceed the legal limits established by the European Union of 0.8 μg g−1. Of the 14 inoculated samples, 57.1% contained fumonisin B1 (0.16–41.0 μg g−1) and fumonisin B2 (range, 0.22–50.0 μg g−1). Positive confirmation of selected samples was carried out using liquid chromatography–tandem mass spectrometry, using triple quadrupole analyzer and operated in the multiple reaction monitoring mode.
This study presents the debonding propagation in single NiTi wire shape memory alloy into linear low-density polyethylene matrix composite the study of using the pull-out test. The aim of this study is to investigate the pull-out tests to check the interfacial strength of the polymer composite in two cases, with activation NiTinol wire and without activation. In this study, shape memory alloy NiTinol wire 2 mm diameter and linear fully annealed straight shape were used. The study involved experimental and finite element analysis and eventually comparison between them. This pull-out test is considered a substantial test because its results have a relation with behavior of smart composite materials. The pull-out test was carried out by a u
... Show MoreA fast moving infrared excess source (G2) which is widely interpreted as a core-less gas and dust cloud approaches Sagittarius A* (Sgr A*) on a presumably elliptical orbit. VLT
Abstract
This paper concerned with study the effect of a graphite micro powder mixed in the kerosene dielectric fluid during powder mixing electric discharge machining (PMEDM) of high carbon high chromium AISI D2 steel. The type of electrode (copper and graphite), the pulse current and the pulse-on time and mixing powder in kerosene dielectric fluid are taken as the process main input parameters. The material removal rate MRR, the tool wear ratio TWR and the work piece surface roughness (SR) are taken as output parameters to measure the process performance. The experiments are planned using response surface methodology (RSM) design procedure. Empirical models are developed for MRR, TWR and SR, using the analysis
... Show MoreBackground: despite the rise in the incidence of renal cell carcinoma attributed to availability of medical imaging, a considerable decline in mortality is an association. Morbidity-wise, the shift from radical nephrectomy to partial nephrectomy is the trend for now. Multiple scoring systems have been introduced over the past decades to help surgeons choose between radical and partial nephrectomy. One commonly used system is the RENAL nephrometry score that was first introduced by Kutikov and Uzzo in 2009.
Objective: to evaluate the role of RENAL nephrometry scoring system in predicting the surgical technique to use to resect renal masses and associated perioperative outcomes.
... Show MorePhotoplethysmography (PPG) is a non-invasive optical technique that employs variations in light absorption produced by alteration in the blood volume in capillaries at the skin during the cardiac cycle. This study aims to understand factors related to PPG morphology; a hand-elevation, the study has modified blood flow to and from the finger was conducted in the laboratory. It is widely established that the position of the limb relative to the heart has an effect on blood flow in arteries and venous. Peripheral digital pulse wave (DPW) signals were obtained from 15 healthy volunteer participants during hand-elevation, and hand-lowering techniques wherein the right hand was lifted and lowered relative to heart level, while the left h
... Show MoreA new series of ?-D-glucose as Schiff bases derivatives is synthesized and characterized with studying their bioactivity. Hydroxyl groups at C (1,2&5,6) sugar moiety are converted into acetal form through a reaction with dry acetone using phosphoric acid and anhydrous zinc chloride as catalysts producing 1,2:5,6-di-O-isopropyledine ?-D-glucofuranose(I). The five memberd ring acetal of C(5,6) is hydrolyzed with acetic acid (65%)and a reaction of the new product with sodium periodate is carried on to get an aldehyde moiety which is used to produce a new series of Schiff bases through reacting with different amino compounds such as 4-amino antipyrene . The suggested chemical structures of the prepared compounds are confirmed by using UV., FT
... Show MoreThe research aims to investigate the possibility of joint auditing in improving the market value of Iraqi companies listed on the Iraq Stock Exchange. The sample was represented by 10 Iraqi companies listed in the Iraq market for the period from 2014-2017 (2 years before implementation and 2 years after implementation) and the research was based on the idea that joint auditing enhances investor confidence and raises their level of security as a result of providing quality and reliable reports, and thus This indicates good news in the market that reflects on the performance of stocks and the market value of companies that adopt joint auditing. The results of the analysis indicate an improvement in the market value, but this improv
... Show MoreThe electronic properties (such as energy gap HOMO levels. LUMO levels, density of state and density of bonds in addition to spectroscopic properties like IR spectra, Raman spectra, force constant and reduced masses as a function of frequency) of coronene C24 and reduced graphene oxide C24OX , where x=1-5, were studied.. The methodology employed was Density Functional Theory (DFT) with Hybrid function B3LYP and 6-311G** basis sets. The energy gap was calculated for C24 to be 3.5 eV and for C24Ox was from 0.89 to 1.6862 eV for x=1-5 ,respectively. These energy gaps values are comparable to the measured gap of Graphene (1-2.2 eV). The spectroscopic properties were compared with experimental measurements, specificall
... Show Moreدور التدقيق الاستراتيجي لإدارة الموارد البشرية في بلورة القدرات التنظيمية دراسة استطلاعية في رئاسة جامعة بغداد