Heart sound is an electric signal affected by some factors during the signal's recording process, which adds unwanted information to the signal. Recently, many studies have been interested in noise removal and signal recovery problems. The first step in signal processing is noise removal; many filters are used and proposed for treating this problem. Here, the Hankel matrix is implemented from a given signal and tries to clean the signal by overcoming unwanted information from the Hankel matrix. The first step is detecting unwanted information by defining a binary operator. This operator is defined under some threshold. The unwanted information replaces by zero, and the wanted information keeping in the estimated matrix. The resulting matrix contains zeros, so the problem is to find a low-rank matrix. Matrix completion is a heuristic NP-hard problem. It is a minimization problem defined by the matrix nuclear norm. In this paper, nuclear norm, and weighted nuclear norm minimization problems are derived to find a low-rank matrix of implemented Hankel matrix from the signal. A Robust Principal Component used to solve a low-rank-sparse matrix finds a low-rank Hankel matrix by solving a minimization problem numerically. The results show that the given methods are efficient in reconstructing and recovering the signals with a rate of more than 96%, with small values of mean square errors
The linguistic researcher reads a systematic crisis, idiomatic problems within the linguistic term coming to the Arab culture. Where most of them return back to problems of receiving these sciences which are represented by phenomena like the multiplicity linguistic term, disturbance translated idiomatic concept and its duality.
Aims of the research :
1-Initializing new textbooks to form linguistic project and Arabic linguistic theory.
2-Determination adjusted knowledge, concepts of Arabian heritage linguistics subject
3-Observation the causes of disturbance crisis of linguistic term and its relation to
... Show MoreThe aim of this book is to present a method for solving high order ordinary differential equations with two point boundary condition of the different kind, we propose semi-analytic technique using two-point osculatory interpolation to construct polynomial solution. The original problem is concerned using two-points osculatory interpolation with the fit equal numbers of derivatives at the end points of an interval [0 , 1] . Also, we discussion the existence and uniqueness of solutions and many examples are presented to demonstrate the applicability, accuracy and efficiency of the methods by compared with conventional method .i.e. VIDM , Septic B-Spline , , NIM , HPM, Haar wavelets on one hand and to confirm the order convergence on the other
... Show MoreMultiple drilling problems are being faced continuously while drilling wells in the southern Iraqi oil fields. Many of which are handled poorly and inefficiently which yields longer non-productive time due to the lack of knowledge about the source of these problems. This study aims to investigate the Basra oil fields formations from Faris to Mishrif, diagnose the potential problems, and present the optimum treatment for each problem.
Gathering of field data and previous studies on the subject, in addition to the field experience of drilling supervisors were all the information bases of this study. Southern Iraqi oil fields were studied and analyzed care
APDBN Rashid, Southern African Linguistics and Applied Language Studies, 2023
Background : Coronary artery disease is theunderlying cause in approximately two thirds of
patients with systolic heart failure ;
Coronary artery angiogriphy may be useful to
define the presence ,
Anatomical characteristics ,and functional
significance of Coronary artery disease in
selected heart failure patients with or without signs
and aymptoms of Coronary artery disease.
Objectives: to verify the clinical usefulness of
coronary angiography (CA) in congestive heart
failure (CHF) patients with no history of ischemic
heart disease and to identify predictive factors for
performing coronary angiography to patients with
congestive heart failure with no obvious ischemia.
Methods :this is a cross-ses
The present study deals with the relationship of noise pollution to the mental health of university students, through the researcher field study with the use of descriptive Correlative approach to investigate this relationship. Noise is one of the elements of environmental pollution that people often expose to in their environment. The problem of noise has been exacerbated now because of cultural and technological progress in crowded cities. As a result, the researchers studied noise as an environmental stimulus that affects the mental health of the human being.The researchers, through their current research try to study a very serious problem, which is the problem of noise pollution on the health side of university students as a
... Show MoreThis paper presents a parametric audio compression scheme intended for scalable audio coding applications, and is particularly well suited for operation at low rates, in the vicinity of 5 to 32 Kbps. The model consists of two complementary components: Sines plus Noise (SN). The principal component of the system is an. overlap-add analysis-by-synthesis sinusoidal model based on conjugate matching pursuits. Perceptual information about human hearing is explicitly included into the model by psychoacoustically weighting the pursuit metric. Once analyzed, SN parameters are efficiently quantized and coded. Our informal listening tests demonstrated that our coder gave competitive performance to the-state-of-the- art HelixTM Producer Plus 9 from
... Show MoreDynamic Thermal Management (DTM) emerged as a solution to address the reliability challenges with thermal hotspots and unbalanced temperatures. DTM efficiency is highly affected by the accuracy of the temperature information presented to the DTM manager. This work aims to investigate the effect of inaccuracy caused by the deep sub-micron (DSM) noise during the transmission of temperature information to the manager on DTM efficiency. A simulation framework has been developed and results show up to 38% DTM performance degradation and 18% unattended cycles in emergency temperature under DSM noise. The finding highlights the importance of further research in providing reliable on-chip data transmission in DTM application.
In this paper, we calculate and measure the SNR theoretically and experimental for digital full duplex optical communication systems for different ranges in free space, the system consists of transmitter and receiver in each side. The semiconductor laser (pointer) was used as a carrier wave in free space with the specification is 5mW power and 650nm wavelength. The type of optical detector was used a PIN with area 1mm2 and responsively 0.4A/W for this wavelength. The results show a high quality optical communication system for different range from (300-1300)m with different bit rat (60-140)kbit/sec is achieved with best values of the signal to noise ratio (SNR).