Routine vaccination activities, such as detection, reporting, and management of adverse events following immunization (AEFIs), are generally handled by healthcare providers (HCPs). Safe vaccines against severe acute respiratory syndrome coronavirus (SARS-CoV-2) were introduced to control the Coronavirus Disease-19 (COVID-19) pandemic. The study aimed to assess the knowledge, perceptions, and practice of HCPs in Iraq about reporting adverse events following COVID-19 vaccination, and their association with sociodemographic variables. The study was a cross-sectional study that was carried out between August and September 2021 at the COVID-19 vaccination centers in Iraq. This study used an online and paper-based questionnaire, which was distributed among HCPs (physicians and pharmacists) in COVID-19 vaccination centers. A total of 117 pharmacists and physicians responded to the survey. Two-thirds of respondents were pharmacists. The majority of the respondents (49.6%) had fair knowledge levels on AEFIs. The perception of 43% of the participants was very good, whereas the perception of 28%, 23%, and 6% of the participants was fair, good, and poor, respectively. The reporting practice of HCPs was inadequate in 53% of respondents. The number of pharmacists who had good knowledge of AEFIs was significantly higher than that of the physicians. The age group (30-39) years of HCPs was significantly associated with more positive perception towards AEFIs. The number of pharmacists that had good perception was significantly higher than that of the physicians. Furthermore, HCPs aged 30 to 39 years had significantly higher reporting practices than other age groups. The study highlighted that the HCPs working at the COVID-19 vaccination centers have low knowledge of AEFIs. On the other hand, HCPs had more positive perception towards reporting AEFIs. Education programs and reference materials are needed to increase their awareness about AEFIs.
The current study included the isolation, purification and cultivation of blue-green alga Oscillatoria pseudogeminata G.Schmidle from soil using the BG-11liquid culture medium for 60 days of cultivation. The growth constant (k) and generation time (G) were measured which (K=0.144) and (G=2.09 days).
Microcystins were purified and determined qualitatively and quantitatively from this alga by using the technique of enzyme linked immunosorbent assay (Elisa Kits). The alga showed the ability to produce microcystins in concentration reached 1.47 µg/L for each 50 mg DW. Tomato plants (Lycopersicon esculentum) aged two months were irrigated with three concentrations of purified microcystins 0.5 , 3.0 and 6.0
... Show MoreBackground: Diabetes mellitus consists of a group of diseases characterized by abnormally high blood glucose levels. Glycated haemoglobin (HbA1c) is a form of haemoglobin used to identify the average concentration of plasma glucose over prolonged periods of time. It is formed in a non-enzymatic pathway by normal exposure of hemoglobin to high levels of plasma glucose, The main alterations observed in the saliva of Type 1 diabetic patients are hyposalivation and alteration in its composition, particularly those related to the levels of glucose. The aim of the present study was to assess the effect of Glycated haemoglobin level on the level of salivary glucose which may have an effect on oral health condition. Materials and methods
... Show MoreBackground: The anticancer impact of Epigallocatechin gallate (EGCG) the highly active polyphenol of green tea was abundantly studied. Though, the exact mechanism of its cytotoxicity is still under investigation. Objectives: Hence, the current study designed to investigate the molecular target of EGCG in HepG2 cells on thirteen autophagy- and/or apoptosis- related genes. Methods: The apoptosis detection analyses such as flow cytometry and dual apoptosis assay were used. The genes expression profile was explored by the real-time quantitative-PCR. Results: EGCG increases G0/G1 cell cycle arrest and the real-time apoptosis markers proteins leading to stimulate apoptos
... Show MoreThe present study employed the NAG-4SX3-3D analyzer to precisely measure the energy response of the sensor. The goal was to enhance the understanding of this technology by providing expert information about the device. This technology offers an economical, quick, accurate, and sensitive approach. By utilizing the turbidity method, Cyproheptadine hydrochloride (CPH) was quantified in pharmaceutical samples without the need for additional substances. CPH is expected to undergo a direct reaction with calcium hexacyanoferrate, resulting in the formation of white precipitates. The linear range for CPH measurement falls within the range of (0.008–30) mM. The relative standard deviation (RSD) for six repetitions at concentrations of (6 and
... Show More