Objective. This study aimed to evaluate and compare the force degradation of two types of elastomeric chains following different periods of immersion in zinc-containing mouthwashes. Materials and Methods. Four hundred and forty pieces of Elasto-Force and Super Elasto-Force elastomeric chains were divided into two control and eight experimental groups. The pieces were stretched to 25 mm on pins mounted on an acrylic block and stored in distilled water at 37°C. The experimental groups were immersed in four different types of mouthwash for one minute twice a day throughout the test period. Ten continuous thermocycles per day between cold and hot water baths (5–55°C) were carried out. Forces were measured at six-time intervals (initial, 24 hours, 1, 3, 6, and 8 weeks). The mean force was calculated and compared among different elastomeric chains, mouthwashes, and times using the t-test and one-way ANOVA test followed by Tukey’s HSD test. The level of significance was set at 0.05. Results. Both types of elastomeric chains had significant force degradation over time (74–79% at 8 weeks). The Super Elasto-Force generated a higher force level than the Elasto-Force elastomeric chain at all time points. SmartMouth Clinical DDS mouthwash had a significantly lower effect on force degradation than other mouthwashes with no significant difference compared to control groups. Conclusions. Depending on these results: there is no clinically significant difference between both types of elastomeric chains, although Super Elasto-Force delivered a higher force level. The pH of the mouthwashes could play a role in force degradation over time, rather than other ingredients including zinc. The SmartMouth mouthwash had the minimum effect on force degradation of elastomeric chains, followed by Halita, Listerine Total Care Zero, and Breath Rx, respectively.
Background: The aims of the study were to evaluate the unclean/clean root canal surface areas with a histopathological cross section view of the root canal and the isthmus and to evaluate the efficiency of instrumentation to the isthmus using different rotary instrumentation techniques. Materials and Methods:The mesial roots of thirty human mandibular molars were divided into six groups, each group was composed of five roots (10 root canals)which prepared and irrigated as: Group one A: Protaper system to size F2 and hypodermic syringe, Group one B: Protaper system to size F2 and endoactivator system, Group two A:Wave One small then primary file and hypodermic syringe, Group two B:Wave One small then primary file and endoactivator system, Gr
... Show MorePraise be to God alone, and prayers and peace be upon the one after whom there is no prophet, and after:
This is a regular judicial search for the issuance, validity, and cancellation of regulations in the Saudi system. It came in an introduction and four demands and a conclusion of the most important results, then a list of the most important sources and references, in which I presented: A brief study on the issuance of regulations in the Kingdom of Saudi Arabia and the stages that they pass through, their validity and application, and the rules that govern this system in terms of people, places and times, then canceling and amending regulations And its rulings, I referred to it to the original sources approved in this section,
... Show MoreThis research aims to study the effect of microwave furnace heat on the mechanical properties and fatigue life of aluminum alloy (AA 2024-T3). Four conditions were used inside microwave furnace (specimens subjected to heat as dry for 30 and 60min. and specimens subjected to heat as wet (water) for 30 and 60 min.), and compared all results with original alloy (AA 2024-T3). Tensile, fatigue, hardness and surface roughness tests were used in this investigation. It is found that hardness of dry conditions is higher than wet conditions and it increases with increasing of time duration inside microwave furnace for dry and wet conditions. Also, tensile strength has the same behavior of hardness, but it increases with decreasing
... Show MoreMedia writing is accuracy writing. Clarity and concision are its predominant features. It is a writing that goes straight to the essence because it has no time to waste. Furthermore, it must be as accurate as scientific writing. It is destined for the average reader and has to be understood by everyone. However, it can be as elegant as literary writing. The variety in its forms of expression does not prevent media writing from having its own amplitude.
In short, this study is a practical approach that aims at studying different kinds of writing styles and identifying the specificity of media writing using some patterns and examples
Background: The marginal seal is essential for sealant success because penetration of bacteria under the sealant might allow caries onset or progression. The aim of the present study was to estimate and compare the microleakage of pit and fissure sealant after various methods of occlusal surface preparation. Materials and methods: Thirty non-carious premolars extracted for orthodontic reasons were equally divided into three groups. In group one, occlusal fissures were opened with round carbide bur, in group two, occlusal surfaces of the teeth were cleaned with a dry pointed bristle brush and samples of group three were cleaned with a slurry of fine flour of pumice in water using rubber cup. Then fissures of all teeth were etched using 35% p
... Show MoreBackground: Esthetic treatment is the options of patient seeking orthodontic treatment. Therefore this study was conducted to measure the concentration of Aluminum, Nickel, Chromium and Iron ions released from combination of monocrysralline brackets with different arch wires immersed in artificial saliva at different duration, to evaluate the corrosion point on different parts of the orthodontic appliances before and after immersion in artificial saliva, and to evaluate the corrosion potential of each group of the orthodontic appliances. Material and methods: Eighty orthodontic sets prepared. Each set represents half fixed orthodontic appliance, from the central incisor to the first molar, for the maxillary arch, each set consisted of molar
... Show MoreTo study the qualitative changes in testis tissue after carbon tetrachloride (CCl4) administration and to determine whether citric acid (CA) has a protective effect against testis damage induced by CCl4. This study compared two types of CA by measuring the histoarchitecture of the testis and serum levels of progesterone, estrogen and testosterone on mice. One of the most produced organic acid is citric acid. In this study, CA produced by microbial fermentation using Aspergillus Niger 5mg/kg and derived from citrus limon 400mg/kg (lemon). Mice were treated with daily intraperitoneal (i.p.) injection for seven successive days after randomly separated into six groups: (1) control, (2) CCl4 (0.02%), (3) limon citric acid (400 mg/kg), (4) CCl4 (
... Show MoreAbstract
Mitoxantrone is an antitumor agent used in the treatment of breast and prostate cancer, acute leukemia, lymphoma, and also in the treatment of multiple sclerosis due to its immunosuppressive properties. The mitoxantrone's cardiotoxicity is irreversible, dose-dependent, and it may occur years after treatment. Zinc is considered as an essential mineral for cell division and the synthesis of DNA and protein; furthermore, such mineral has an important role in states of cardiovascular diseases; and may have protective effects in coronary artery disease and cardiomyopathy.
Objective: The current study is designed to investigate effects of two different doses of zinc sulfat
... Show More
This paper studies the effect of contact areas on the transient response of mechanical structures. Precisely, it investigates replacing the ordinary beam of a structure by two beams of half the thickness, which are joined by bolts. The response of these beams is controlled by adjusting the tightening of the connecting bolts and hence changing the magnitude of the induced frictional force between the two beams which affect the beams damping capacity. A cantilever of two beams joined together by bolts has been investigated numerically and experimentally. The numerical analysis was performed using ANSYS-Workbench version 17.2. A good agreement between the numerical and experimental results has been obtained. In general, results s
... Show More