Objectives. This study aimed at finding out whether anterior teeth angulation and inclination have a relationship with the maxillary teeth and dental arch dimensions. Methods. Fifty study models with normal occlusion were selected from the archive of the Department of Orthodontics at Baghdad Dental Faculty. Maxillary dental arch width and length at different points were determined in addition to measuring anterior teeth angulation, inclination, crown thickness, overjet, overbite, and Bolton’s ratios. The unpaired t-test and Pearson’s correlation coefficient test were used for data analysis. Results. No statistical gender differences were reported in all measurements except the dental arch widths and length where males had significantly higher mean values. Only the maxillary incisor’s inclination showed a direct weak significant correlation with the total arch length. Conclusions. The inclination of upper incisors had a minimal effect on increasing dental arch length.
In this paper, we deal with a dynamical system that can demonstrate a chaotic attractor of Rossleroscillator. We simulate the Rosslerequations numerically then we investigate the model experimentally. Numerically, the Rossler parameter a and b were fixed and c was changed.The evolution of the system exhibits period, period-doubling, second period doubling, and chaos when control parameters are changed. This evolution can be seen by analyze the time series, the bifurcation diagrams and phase space. Experimentally, the evolution of the system exhibited the same numerical behavior by changing the resistance (Rv) in Rossler circuit that represent as control parameter.
ABSTRACT Background: According to Branemark’s protocol, the waiting period between tooth extraction and implant placement is 6–8 months; this is the late placement technique. Achieving and maintaining implant stability are prerequisites for a dental implant to be successful. Resonance Frequency Analysis (RFA) is a noninvasive diagnostic method that measures implant stability. The aim of this study was to investigate the influence of treatment protocol and implant dimensions on primary implant stability utilizing RFA. Materials and methods: This study included 63 Iraqi patients (37 male, 26 female; ranging 22-66 years). According to treatment protocol, the sample was divided into 2 groups; A (delayed) & B (immediate). Dental im
... Show MoreExperimental study on the effect of cylindrical hollow cathode, working pressure and magnetic field on spatial glow distribution and the characteristics of plasma produced by dc discharge in Argon gas, were investigated by image analyses for the plume within the plasma. It was found that the emission intensity appears as a periodic structure with many peaks appeared between the electrodes. Increasing the pressure leads to increase the number of intensity peaks finally converted to continuous form at high pressure, especially with applied of magnetic field, i.e. the plasma is more stable with the presence of magnetic field. The emission intensity study of plasma showed that the intensity has a maximum value at 1.07 mbar pressure and decre
... Show MoreThis research aims to study the methods of reduction of dimensions that overcome the problem curse of dimensionality when traditional methods fail to provide a good estimation of the parameters So this problem must be dealt with directly . Two methods were used to solve the problem of high dimensional data, The first method is the non-classical method Slice inverse regression ( SIR ) method and the proposed weight standard Sir (WSIR) method and principal components (PCA) which is the general method used in reducing dimensions, (SIR ) and (PCA) is based on the work of linear combinations of a subset of the original explanatory variables, which may suffer from the problem of heterogeneity and the problem of linear
... Show MoreBackground: Due to the variations in tooth anatomy and size among different populations, this study aimed to compare the mesiodistal width of primary second molars in Iraqi children with the mesiodistal width of stainless-steel crowns from different companies. Materials and Methods: This cross-sectional study was conducted on 220 intact maxillary and mandibular primary second molars selected from boys and girls’ Iraqi children aged 8-9 years collected from different primary schools in Baghdad city. The mesiodistal dimensions of the selected teeth and the available maxillary and mandibular stainless-steel crowns from three different companies were measured by using a 3-D scanner, and then the whole measurements were calculated usin
... Show MoreThe Qur'an is an inexhaustible source for researchers, and all of them find a rich material for its research, and no wonder in it is the book of the greatest Arabic. Quranic research has been an attempt to extract the secret in the miracle of the Koran, and not the Quranic miracle is limited to the word and its meaning, but that the miracle extends to include every sound in motion or silent; the sound performance of the Quranic text increases the meaning of beauty and earns the word heartbeat, Souls; and this may be due to the beauty of voice in the performance and harmony between sounds and words, and harmony between the exits and descriptions, or the tides of the tides,
Based on the above and to show the miraculous aspects of the Qu
Objectives This work presents laser coating of grade 1 pure titanium (Ti) dental implant surface with sintered biological apatite beta-tricalcium phosphate (β-TCP), which has a chemical composition close to bone. Materials and methods Pulsed Nd:YAG laser of single pulse capability up to 70 J/10 ms and pulse peak power of 8 kW was used to implement the task. Laser pulse peak power, pulse duration, repetition rate and scanning speed were modulated to achieve the most homogenous, cohesive and highly adherent coat layer. Scanning electron microscopy (SEM), energy dispersive X-ray microscopy (EDX), optical microscopy and nanoindentation analyses were conducted to characterise and evaluate the microstructure, phases, modulus of elasticity
... Show MoreBackground. The anterior communicating artery (ACoA) complex consists of the ACoA, the pre-and post-communicating segments of the anterior cerebral artery, and the recurrent artery of Heubner. It is the most common site for anatomical variations in the circle of Willis. Such variations can mimic intracranial aneurysms. Case description. A 30-year-old female presented with recurrent episodes of extreme headache and bilateral tinnitus. A brain computed tomography (CT) scan showed no significant lesions, while her CT-angiography (CTA) showed an enlarged vascular lesion at the ACoA, raising the suspicion for an ACoA aneurysm. A repeated CTA revealed a rare anatomical variation with a pattern of cross dominance in the ACoA complex;
... Show MoreAbstract
The cultural contrast is considered of the essential subjects in the field of administration of international businesses which have great and effective role for representation in one social system for the individuals have various belongings, and the nursing performance is considered an essential basic for health care, thus a discussion for two variables have done to formulate the intellectual frame for this research which are( the cultural contrast and the nursing performance). depended a questionnaire as a research tool by(90) he/ she nurses of the Iraqis and the arrivals( the
... Show MoreIntroduction: The use of screw-retained hybrid arch bars (HABs) is a relatively recent development in the treatment of mandibular fractures. The purpose of this study is to compare the clinical outcome between HAB and the conventional Erich arch bar (EAB) in the closed treatment of mandibular fractures. Materials and methods: This study included 18 patients who were treated for mandibular fractures with maxillomandibular fixation (MMF), patients were randomly assigned into a control group (n = 10) in which EAB was used and study group (n = 8) in which HAB was used. The outcome variables were time required for application and removal, gingival inflammation scores, postoperative complications, and incidence of wire-stick injury or gloves perf
... Show More