Preferred Language
Articles
/
rxfOoZIBVTCNdQwClruj
Bond Strength Survival of a Novel Calcium Phosphate-Enriched Orthodontic Self-Etching System after Various Ageing Protocols: An In Vitro Study
...Show More Authors

Objective. This study aimed to evaluate the orthodontic bond strength and enamel-preserving ability of a hydroxyapatite nanoparticles-containingself-etch system following exposure to various ageing methods. Materials and Methods. Hydroxyapatite nanoparticles (nHAp) were incorporated into an orthodontic self-etch primer (SEP, Transbond™ plus) in three different concentrations (5%, 7%, and 9% wt) and tested versus the plain SEP (control) for shear bond strength (SBS), adhesive remnant index (ARI) scores, and enamel damage in range-finding experiments using premolar teeth. The best-performing formulation was further exposed to the following four artificial ageing methods: initial debonding, 24 h water storage, one-month water storage, and one-month acid challenge. A field-emission scanning electron microscope (FE-SEM) was used to examine the integrity of debonded enamel surfaces and calcium-phosphates (CaPs) reprecipitation. Results. The best-performing formulation (7% nHAp-SEP) resulted in significantly lower SBS ( p < 0.001 ) than the control SEP following the four artificial ageing methods. Nevertheless, it survived the ageing protocols and yielded clinically acceptable SBS with the advantages of leaving minimal adhesive residue, preserving enamel integrity and smoothness, and inducing CaP reprecipitation as confirmed by FE-SEM images. Conclusions. A newly developed SEP produced adequate orthodontic bond strengths and left unblemished debonded enamel surfaces with minimal remnant adhesive and remineralisation potential, thereby suggesting simpler and safer bonding/debonding procedures.

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Engineering
A Impact of High Voltage Direct Current Link on Transmission Line in Kurdistan Power System
...Show More Authors

Kurdistan power system is expanded along years ago. The electrical power is transmitted through long transmission lines. The main problem of transmission lines is active and reactive power losses. It is important to solve this issue, unless, the most of electrical energy will lost over transmission system. In this study, High Voltage Direct Current links/bipolar connection were connected in a power system to reduce the power losses. The 132kV, 50 Hz, 36 buses Kurdistan power system is used as a study case. The load flow analysis was implemented by using ETAP.16 program in which Newton-Raphson method for three cases. The results show that the losses are reduced after inserted HVDC links.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Energy Conversion And Management
Improved PCM melting in a thermal energy storage system of double-pipe helical-coil tube
...Show More Authors

View Publication
Scopus (153)
Crossref (148)
Scopus Clarivate Crossref
Publication Date
Sat Feb 02 2019
Journal Name
Journal Of The College Of Education For Women
Code-Switching in Language : An Applied Study: تغییر الشفرة اللغویة: دراسة تطبیقیة
...Show More Authors

.

View Publication Preview PDF
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
In vitro MIC of Itraconazole Against Different Isolates of Candida albicans
...Show More Authors

In vitro antifungal susceptibility test of itraconazole was carried out against 38 isolates from nails, skin, oral cavity, vagina and wounds, This study was done in Ramadi Teaching Hospital in period from January to August 2010. According to the National Committee for Clinical Laboratory Standard (NCCLS ) M 27- A by using the broth dilution method. Inoculum size was 1-5X103 CFU/ ml, while final concentrations of itraconazole ranged from 0.025 – 6.4 μg / ml by using RPMI – 1640 broth media and the fungus was incubated at 35 oC.  No resistant stain was recorded. MIC ranged from 0.05 – 6.4 μg / ml and the Mean ± SEM was 0.89 ± 0.28. MIC for nail isolates was 0.05 –

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 02 2013
Journal Name
Baghdad Science Journal
Inhibitory Effects of Chalcone on the Replication of Poliovirus in Vitro
...Show More Authors

The compound chalcon originally is extracted form some plant and herbs, the studies of the antiviral activity of this compound were done in two cell line cultures the L2OB and RD, the compound relatively non toxic to both cell lines of the concentration of 32?g/ml or less ,the compound have significantly anti poliovirus activity in both L2OB cell line and RD cell line, we find that the concentration of 0.03 ?g/ml or more inhibit the 100TCDID50 of the poliovirus .The therapeutic index(TI)used in this study to evaluate the drug activity ,( TI is the ratio of dose of drug which is just toxic to the cells to the does which is just inhibit the viral multiplication, if this index more than one the margin of safety of drug is according great ) .In

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Aug 31 2017
Journal Name
Journal Of Engineering
The Phenomenon of Division and Modification of The Individual Houses in Baghdad after 2003
...Show More Authors

The Research deals with the negative phenomena which appeared in the urban scenes of the  Iraqi cities after 2003, particularly trespassing the architectural design of the urban Individual houses.  Many academic researchers , critics, and cultural circles, drawn attention to the impact of  political and cultural variable change on such phenomena  without detailed  analysis . The research problem  is set according to central questions : If the phenomena is the trespass , what
are the sides which are being trespassed  in the division of the individual house? , If the diagnosis of the phenomena denotes perceived repetition of the cases , So what's size of this transposes on the architectural design of t

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2016
Journal Name
Journal Of Madenat Al-elem University College
Histopathological changes induced after oral administration of acetamiprid in kidneys of male albino mice
...Show More Authors

View Publication
Publication Date
Tue Dec 05 2023
Journal Name
Baghdad Science Journal
An improved neurogenetic model for recognition of 3D kinetic data of human extracted from the Vicon Robot system
...Show More Authors

These days, it is crucial to discern between different types of human behavior, and artificial intelligence techniques play a big part in that.  The characteristics of the feedforward artificial neural network (FANN) algorithm and the genetic algorithm have been combined to create an important working mechanism that aids in this field. The proposed system can be used for essential tasks in life, such as analysis, automation, control, recognition, and other tasks. Crossover and mutation are the two primary mechanisms used by the genetic algorithm in the proposed system to replace the back propagation process in ANN. While the feedforward artificial neural network technique is focused on input processing, this should be based on the proce

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Reliability of the multipeg™ transducer in measuring dental implant stability by using a resonance frequency analysis device (Osstell®): An observational clinical study
...Show More Authors

Background: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and M

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Wed Jan 15 2020
Journal Name
Arab World English Journal
A Study of Irony in Political Discourse
...Show More Authors

View Publication Preview PDF
Crossref (3)
Clarivate Crossref