Preferred Language
Articles
/
rxf6fI4BVTCNdQwC9kq_
Brown-Sequard syndrome associated with a spinal cord injury caused by a retained screwdriver: A case report and literature review
...Show More Authors
Background:

Nonmissile penetrating spine injury (NMPSI) represents a small percent of spinal cord injuries (SCIs), estimated at 0.8% in Western countries. Regarding the causes, an NMPSI injury caused by a screwdriver is rare. This study reports a case of a retained double-headed screwdriver in a 37-year-old man who sustained a stab injury to the back of the neck, leaving the patient with a C4 Brown-Sequard syndrome (BSS). We discuss the intricacies of the surgical management of such cases with a literature review.

Methods:

PubMed database was searched by the following combined formula of medical subjects headings, (MESH) terms, and keywords: (((SCIs [MeSH Terms]) OR (nmpsi [Other Term]) OR (nonmissile penetrating spinal injury [Other Term]) OR (nonmissile penetrating spinal injury [Other Term])) AND (BSS [MeSH Terms])) OR (BSS [MeSH Terms]).

Results:

A total of 338 results were found; 258 were case reports. After excluding nonrelated cases, 16 cases were found of BSS induced by spinal cord injury by a retained object. The male-to-female ratio in these cases is 11:5, and ages ranged from 11 to 72. The causes of spinal cord injury included screwdrivers in three cases, knives in five cases, and glass in three cases. The extracted data were analyzed.

Conclusion:

Screwdriver stabs causing cervical SCIs are extremely rare. This is the first case from Iraq where the assault device is retained in situ at the time of presentation. Such cases should be managed immediately to carefully withdraw the object under direct vision and prevent further neurological deterioration.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 31 2016
Journal Name
Al-kindy College Medical Journal
A Comparison of Sagittal Sections of Short T1inversion Recovery and T2 Weighted Fast Spin Echo Magnetic Resonance Sequences for Detection of Multiple Sclerosis Spinal Cord Lesions
...Show More Authors

Background: Multiple sclerosis is a chronic autoimmune inflammatory demyelinating disease of the central nervous system of unknown etiology. Different techniques and magnetic resonance image sequences are widely used and compared to each other to improve the detection of multiple sclerosis lesions in the spinal cord. Objective: To evaluate the ability of MRI short tau inversion recovery sequences in improvementof multiple sclerosis spinal cord lesion detection when compared to T2 weighted image sequences. Type of the study: A retrospective study. Methods: this study conducted from 15thAugust 2013 to 30thJune 2014 at Baghdad teaching hospital. 22 clinically definite MS patients with clinical features suggestive of spinal cord involvement,

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2011
Journal Name
Al-kindy College Medical Journal
Serum Lipoprotein (A) in Patients with Fibromyalgia Syndrome
...Show More Authors

Background: Fibromyalgia syndrome (FMS) is the
most common rheumatic cause of diffuse pain and
multiple regional musculoskeletal pain and disability.
Objective: is to assess the contribution of serum
lipoprotein (A) in the pathogenesis of FMS patients.
Methods: One hundred twenty two FMS patients
were compared with 60 healthy control individuals
who were age and sex matched. All FMS features and
criteria are applied for patients and controls; patients
with secondary FMS were excluded. Serum
Lipoprotein (A): [Lp(A)], body mass index (BMI), &
s.lipid profile were determined for both groups.
Results: There was a statistical significant difference
between patients &controls in serum lipoprotein

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 22 2025
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Snare-Assisted Retrieval of an Embolized Broken Double Lumen from the Heart of a Female Patient Diagnosed with End Stage Kidney Disease: A Case Report
...Show More Authors

Foreign body embolization is a rare but serious iatrogenic complication that might necessitate transcatheter or even surgical retrieval. A broken double-lumen catheter was snared using a goose neck snare kit. The procedure was successful, and the patient experienced no further complications.

View Publication
Scopus Crossref
Publication Date
Wed Dec 01 2021
Journal Name
International Journal Of Research In Social Sciences & Humanities. E-issn
CONCEPTS OF LITERATURE: COMPARATIVE LITERATURE BY HENRY GIFFORD (an Article REVIEW).
...Show More Authors

BOOK REVIEW

Publication Date
Sat Oct 20 2018
Journal Name
Journal Of Economics And Administrative Sciences
THE IMPACT OF MANAGEMENT CONTROL SYSTEMS (MCS) ON ORGANIZATIONS PERFORMANCE A LITERATURE REVIEW
...Show More Authors

The impact of management control systems (MCS) on organizations performance empirical research has been the subject of numerous studies during the past decade in developed and emerging economies. In the contemporary competitive, complex and changing global business environment, firms are being challenged to adopt business models that enable them to address the strategic uncertainties and risks they face in their business environments. The main issue of this study is that management accounting researchers argue that one of the ways firms can continually rejuvenate themselves to survive and succeed in these complex and uncertain environments is to understand the role of management control systems in Formulating a b

... Show More
View Publication
Crossref (3)
Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Engineering
Recycled Concrete Aggregated for the use in Roller Compacted Concrete: A Literature Review
...Show More Authors

The using of recycled aggregates from construction and demolition waste (CDW) can preserve natural aggregate resources, reduce the demand for landfill, and contribute to a sustainable built environment. Concrete demolition waste has been proven to be an excellent source of aggregates for new concrete production. At a technical, economic, and environmental level, roller compacted concrete (RCC) applications benefit various civil construction projects. Roller Compacted Concrete (RCC) is a homogenous mixture that is best described as a zero-slump concrete placed with compacting equipment, uses in storage areas, dams, and most often as a basis for rigid pavements. The mix must be sufficiently dry to support

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Wed May 04 2022
Journal Name
Int. J. Nonlinear Anal. Appl.
Knee Meniscus Segmentation and Tear Detection Based On Magnitic Resonacis Images: A Review of Literature
...Show More Authors

The meniscus has a crucial function in human anatomy, and Magnetic Resonance Imaging (M.R.I.) plays an essential role in meniscus assessment. It is difficult to identify cartilage lesions using typical image processing approaches because the M.R.I. data is so diverse. An M.R.I. data sequence comprises numerous images, and the attributes area we are searching for may differ from each image in the series. Therefore, feature extraction gets more complicated, hence specifically, traditional image processing becomes very complex. In traditional image processing, a human tells a computer what should be there, but a deep learning (D.L.) algorithm extracts the features of what is already there automatically. The surface changes become valuable when

... Show More
Publication Date
Mon Mar 10 2025
Journal Name
Proceedings On Engineering Sciences
WAREHOUSE IN INDUSTRY 4.0 BASED DRONE, COMPUTER VISION, AND ARTIFICIAL INTELLIGENCE TECHNOLOGIES: A LITERATURE REVIEW
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
مجلة ميسان للدراسات الأكاديمية
Adhesion Of 3D Printed Acrylic Resin With Silicone Soft Liner After Sandblast Surface Treatment:, A Review Of Literature
...Show More Authors

View Publication
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Biochemical & Cellular Archives
MORPHOLOGICAL STUDY OF THE BRAIN AND SPINAL CORD OF THE IRAQI FROG, RANA RIDIBUNDA RIDIBUNDA
...Show More Authors

The frog has a highly developed nervous system. It consists of a brain, a spinal cord and nerves. The brain is the only center for the control of all vital activities as it receives impulses from different parts of the body through sensory nerves and issues orders through motor fibers to different parts of the body for appropriate action. The Aims of studyis general morphological structural of the brain and spinal cord in the Iraqi frog Rana ridibunda ridibunda. The brains of twenty of frogs belonging to class Amphibia were studied using conventional techniques of dissecting microscopy. All samples were sacrificed and anesthetized and then they were removed completely from the neurocranium, cranial, sensory nerves and the meninges and trans

... Show More
Scopus