Preferred Language
Articles
/
rxebC5IBVTCNdQwCm501
Banach gamma-algebra modules and full stability
...Show More Authors

In this paper the full stable Banach gamma-algebra modules, fully stable Banach gamma-algebra modules relative to ideal are introduced. Some properties and characterizations of these classes of full stability are studied.

Scopus
View Publication
Publication Date
Wed Aug 28 2019
Journal Name
Journal Of Engineering
Influence of Liquid Asphalt on Resilient Modules and Permanent Deformation of Recycled Asphalt Concrete
...Show More Authors

Tests were performed on Marshall samples and were implemented for permanent deformation and resilient modulus (Mr) under indirect tensile repeated loading (ITRL), with constant stress level. Two types of liquid asphalt (cutback and emulsion) were tried as recycling agents, aged materials that were reclaimed from field (100% RAP), samples were prepared from the aged mixture, and two types of liquid asphalt (cutback and emulsion) with a weight content of 0.5% were utilized to prepare a recycled mixture. A group of twelve samples was prepared for each mixture; six samples were tested directly for ITRL test (three samples at 25˚C and three samples at 40˚C), an average value for ITRL for every three samples was calculated (

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 10 2017
Journal Name
Superconductor Science And Technology
Conceptual designs of conduction cooled MgB<sub>2</sub> magnets for 1.5 and 3.0 T full body MRI systems
...Show More Authors

View Publication
Scopus (61)
Crossref (58)
Scopus Clarivate Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Dosimetric Verification of Gamma Passing Rate for Head and Neck Cases Treated with Intensity Modulated Radiation Therapy (IMRT) Treatment Planning Technique
...Show More Authors

Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Gamma radiation induced changes in the optical properties of CdTe thin films for dosimetric purposes
...Show More Authors

The effect of 0.662MeV gamma radiation on the optical properties of the CdTe thin films was studied. 300nm thickness of CdTe samples were irradiated with doses (10, 20, 30,60krad) in room temperature. The absorption spectra for all the samples were recorded using UV- Visible spectrometer in order to calculate the energy gap, width of localized states and optical constants(refractive index, extinction coefficient, real and imaginary parts of dielectric constant). The optical energy gap was found to decrease from (1.53 to 1.48 eV), while the width of localized states increased from (1.34 to 1.49 eV) with the increasing of radiation dose. The behavior of energy gap with the irradiation dose makes the material a good candidate for dosimetry

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
2nd International Conference For Engineering Sciences And Information Technology (esit 2022): Esit2022 Conference Proceedings
Ideals of the full transformation semigroup of a free left G-act on n-generators
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Jun 06 2010
Journal Name
J Of Mustansiriya College Of Dentistry
the usefulness of Ramfjord teeth to represent the full-mouth pocket depth in epidemiology study
...Show More Authors

Publication Date
Thu Mar 09 2017
Journal Name
Sensors
A Multimodality Hybrid Gamma-Optical Camera for Intraoperative Imaging
...Show More Authors

The development of low profile gamma-ray detectors has encouraged the production of small field of view (SFOV) hand-held imaging devices for use at the patient bedside and in operating theatres. Early development of these SFOV cameras was focussed on a single modality—gamma ray imaging. Recently, a hybrid system—gamma plus optical imaging—has been developed. This combination of optical and gamma cameras enables high spatial resolution multi-modal imaging, giving a superimposed scintigraphic and optical image. Hybrid imaging offers new possibilities for assisting clinicians and surgeons in localising the site of uptake in procedures such as sentinel node detection. The hybrid camera concept can be extended to a multimodal detec

... Show More
View Publication
Scopus (24)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Thu Feb 11 2021
Journal Name
Physics In Medicine &amp; Biology
Stereoscopic portable hybrid gamma imaging for source depth estimation
...Show More Authors
Abstract<p>Advances in gamma imaging technology mean that is now technologically feasible to conduct stereoscopic gamma imaging in a hand-held unit. This paper derives an analytical model for stereoscopic pinhole imaging which can be used to predict performance for a wide range of camera configurations. Investigation of this concept through Monte Carlo and benchtop studies, for an example configuration, shows camera-source distance measurements with a mean deviation between calculated and actual distances of <5 mm for imaging distances of 50–250 mm. By combining this technique with stereoscopic optical imaging, we are then able to calculate the depth of a radioisotope source beneath a surfa</p> ... Show More
View Publication
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Gamma irradiation effect on characterization of MoO3 nanostructures films
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Thu Dec 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
DETERMINATION OF THE OPTIMUM OPERATING CONDITIONS IN THE GRANULATION OF GAMMA ALUMINA CATALYST SUPPORT
...Show More Authors

Granulation Technique for Gamma Alumina Catalyst Support was employed in inclined disk granulator (IDG), rotary drum granulator (RD) and extrusion – spheronization equipments .Product with wide size range can be produced with only few parameters like rpm of equipment, ratio of binder and angle of inclination. The investigation was conducted for determination the optimum operating conditions in the three above different granulation equipments.
Results reveal that the optimum operating conditions to get maximum granulation occurred at ( speed: 31rpm , Inclination:420 , binder ratio:225,300% ) for the IDG,( speed: 68rpm , Inclination: 12.50 , binder ratio: 300% ) for the RD and ( speed:1200rpm , time of rotation: 1-2min )for the Caleva

... Show More
View Publication Preview PDF