Preferred Language
Articles
/
rhcEt40BVTCNdQwC3Bmn
Design and Fabrication of an Electromechanical Tester to Perform Two-dimensional Tensile Testing for Flexible Materials
...Show More Authors

There are many diseases that affect the arteries, especially those related to their elasticity and stiffness, and they can be guessed by estimating and calculating the modulus of elasticity. Hence, the accurate calculation of the elastic modulus leads to an accurate assessment of these diseases, especially in their early stages, which can contribute to the treatment of these diseases early. Most of the calculations used the one-dimensional (1D) modulus of elasticity. From a mechanical point of view, the stresses to which the artery is subjected are not one-dimensional, but three-dimensional. Therefore, estimating at least a two-dimensional (2D) modulus of elasticity will necessarily be more accurate. To the knowledge of researchers, there is a lack of published research on this subject, as well as a paucity of research that designed and implemented a 2D tensile testing device (2DTTD). However, there is no inspection of arterial flexibility and elasticity using the 2DTTD adequately studied before. Therefore, the aim of this work is to design and implement the 2DTTD to scrutinize if there is a difference between the 1D and 2D tensile examination. Different sized rectangular silicone specimens were manually fabricated; they were tested individually using the fabricated 2DTTD, which mainly comprises four actuators synchronously working with the same velocity and axial load force, two at each axis. As expected using the 2DTTD, the dimensions of the specimen remarkably influence the tensile testing results; the strain and stress rates and the modulus of elasticity were influenced. To validate the acquired 2D tensile testing results, the 1D tensile testing was performed using the same fabricated 2DTTD and compared to results gained using another tensile testing apparatus. During the verification process, the input data for models calibration were sufficiently and accurately provided. The results showed reasonable precision and reliability in calculations of the 2D stress and strain rates during the whole deformation process. Each mechanical device that has been used has the possibility to stretch and squeeze the sample and log the change in the specimen elongation. The authors thought that the present experimental methodology was applied to the linear mechanical device successfully, where the encoder that is attached to tested samples was in the principal direction. The present method is used to measure the deformation in a manner that differs from the traditional digital image correlation method, which required a toolset that is more expensive, where it incorporates high-accuracy optical equipment.

Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 15 2020
Journal Name
Al-academy
Formal Data of Bauhaus School and their Implications for Fabrics and Costumes Design: نور منصور خميس-وسن خليل ابراهيم
...Show More Authors

The current research discusses the topic of the formal data within the methodological framework through defining the research problem, limits and objectives and defining the most important terms mentioned in this research. The theoretical framework in the first section addressed (the concept of the Bauhaus school, the philosophy of the Bauhaus school and the logical bases of this school). The second section dealt with (the most important elements and structural bases of the Bauhaus school) which are considered the most important formal data of this school and their implications on the fabrics and costumes design. The research came up with the most important indicators resulting from the theoretical framework.
Chapter three defined the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue May 23 2023
Journal Name
Journal Of Engineering
EXPERIMENTAL AND THEORETICAL STUDY OF TWO-PHASE HEAT PIPE
...Show More Authors

In this study, thermal characteristics of a two-phase closed heat pipe were investigated experimentally and theoretically. A two-phase closed heat pipe (copper container, Fluorocarbon FC-72 (C6F14) working fluid) was fabricated to examine its performance under the effect of input heat flux range of 250–1253 W/m2 , 70% fill charge ratio and various tilt angles. The temperature distribution along the heat pipe, input heat to evaporator section, and output heat from condenser were monitored. A comprehensive mathematical model was developed to investigate the steadystate heat transfer performance of a two-phase closed heat pipe. A steady state analytical model, is presented to determine important parameters on the design of two-phase close

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 10 2019
Journal Name
Journal Of The College Of Education For Women
Denotation of Stanza and couplet between the two sonnets
...Show More Authors

The stanza in the sonnet has been defined as a set of poetic lines followed after proem
and be the same meter as that of proem in complete stanza, but in rhyme scheme different
from that meter. The couplet is defined as set of poetic lines that followed the stanza and be as
the same meter as that of stanza, but with different rhyme scheme. This definition is approved
by all specialized in field of Andalus literature and it was also proven to them that this
construction emptied of indications. This meter has endeavored to prove that that there were a
difference in denotation for meaning between the stanza and couplet. Thus, the sonneteers
have outweighed the sonnet of the blind "Tutaili" to their sonnets as they felt

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Performance quality of single and ?two stage solar concentrators
...Show More Authors

The performance of single and two stage solar concentrator were studied ' " The ratio of the primary to the secondary mirrors diameter is taking to be 0.5, depending on the theoretical calculation for the accumulated energy by the concentrator with ratio between 0.0 to 0.9. The design of the systems were designed and examined by using a ray-tracing program. The efficiency of the single and the two stage concentrators are calculated and compared with and without cooling systems.

View Publication Preview PDF
Publication Date
Sun Jun 22 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An Evaluation of Olive Oil as a Separating Medium and Its Effect on Some Mechanical Properties of Processed Acrylic Resin Denture Base (A Comparative Study). Part Two
...Show More Authors

Background: During acrylic resin processing, the mold must be separated from the surface of the gypsum to prevent liquid resin from penetrating into the gypsum, and water from the gypsum seeping into the acrylic resin. For many years, tin foil was the most acceptable separating medium, and because it's difficult to apply, a tin-foil substitute is used. In this study, olive oil is used as an alternative to tin foil separating medium for first time, and evaluating its effect as a separating medium on some mechanical properties such as (indentation hardness and transverse strength) of acrylic resins denture base comparing it with those processed using tin-foil and tin foil substitute such as (cold mold seal) separating medium. Materials and M

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 01 2011
Journal Name
Journal Of Economics And Administrative Sciences
Analysis of the composite variance of dissected splitting experiments carried out according to the Latin box design
...Show More Authors

In this research we present An idea of setting up same split plots experiments in many locations and many periods by Latin Square Design. This cases represents a modest contribution in area of design and analysis of experiments. we had written (theoretically)  the general plans, the mathematical models for these experiments, and finding the derivations of EMS for each component (source) of sources of variation of the analysis of variance tables which uses for the statistical analysis for these expirements

View Publication Preview PDF
Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Naturally occurring radioactive materials and related hazard indices in Ahdeb oil field
...Show More Authors

In this work, measurements of activity concentration of naturally occurring radioactive materials (NORM) isotopes and their related hazard indices for several materials such as crude oil, sludge and water in Ahdeb oil fields in Waste governorate using high pure germanium coaxial detection technique. The average values for crude oil samples were174.72Bq/l, 43.46Bq/l, 355.07Bq/l, 264.21Bq/l, 122.52nGy/h, 0.7138, 1.1861, 0.601 mSv/y, 0.1503mSv/y and 1.8361 for Ra-226, Ac-228, K-40, Ra eq, D, H-external and H-internal respectively. According to the results; the ratio between 238U to 232Th was 4, which represents the natural ratio in the crust earth; therefore, one can be strongly suggested that the geo-stricture of the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 29 2016
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Comparison Between Two Approaches (MLE &DLS) to Estimate Frechet Poisson Lindley Distribution Compound by Using Simulation
...Show More Authors

  In this paper simulation technique plays a vital role to compare between two approaches Maximum Likelihood method and Developed Least Square method to estimate the parameters of Frechet Poisson Lindley Distribution Compound. by coding using Matlab software program. Also, under different sample sizes via mean square error. As the results which obtain that Maximum Likelihood Estimation method is better than Developed Least Square method to estimate these parameters to the proposed distribution.

View Publication Preview PDF
Publication Date
Tue Aug 03 2021
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Enhancing Assurance Services Using Non-Renewable Resources Standard (NR0401) “Constructive Materials: Applied Research for Kufa Cement Factory
...Show More Authors

The importance of this study stems from the importance of preserving the environment and creating a clean sustainable environment from waste and emissions and all the operations of industrial companies in general and cement companies in particular by activating sustainability accounting standards. The research aims to identify and diagnose deviations in violation of sustainability standards by employing the non-renewable resources standard (NR0401) For the construction industries to create a sustainable audit environment, the deductive approach was followed in the theoretical side and the inductive and descriptive approach to the practical side. The most important results of the research were the possibility of applying sustainab

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
DESIGN AND VALIDATION OF A LOW−COST WIRELESS ELECTROMYOGRAPHY SYSTEM : DESIGN AND VALIDATION OF A LOW−COST WIRELESS ELECTROMYOGRAPHY SYSTEM
...Show More Authors

Electromyography (EMG) is being explored for evaluating muscle activity. For gait analysis, EMG needs to be small, lightweight, portable device, and with low power consumption. The proposed superficial EMG (sEMG) system is aimed to be used in rehabilitation centers and biomechanics laboratories for gait analysis in Iraq.

The system is built using MyoWare, which is controlled by using STM32F100 microcontroller. The sEMG signal is transferred via Bluetooth to the computer (about 30m range) for further processing. MATLAB is used for sEMG signal conditioning. The overall system cost (without computer) is about $80. The proposed system is validated using wired NORAXON EMG using the mean root mean squared metho

... Show More
View Publication Preview PDF