Orthogonal polynomials and their moments have significant role in image processing and computer vision field. One of the polynomials is discrete Hahn polynomials (DHaPs), which are used for compression, and feature extraction. However, when the moment order becomes high, they suffer from numerical instability. This paper proposes a fast approach for computing the high orders DHaPs. This work takes advantage of the multithread for the calculation of Hahn polynomials coefficients. To take advantage of the available processing capabilities, independent calculations are divided among threads. The research provides a distribution method to achieve a more balanced processing burden among the threads. The proposed methods are tested for va
... Show MoreBackground: The development of non steroidal anti-inflammatory drugs (NSAIDs) was based principally on inhibiting cyclooxygenases (COX) activity. However, the identification of two
COX- isoforms (i.e., COX-1 and COX-2) with different physiological effects has led to the development of COX-2 specific NSAIDs, with fewer adverse effects than traditional NSAIDs.
Therefore, They are expected to produce anti-inflammatory activity with minimal adverse effects on GI mucosa, as well as, other structures and cells such as platelets.
The aim of this study is to evaluate the effect of selectivity of COX-2 inhibitors on many organs and systems function such as the hepatobiliary system, platelets function, as well as, seru
Flow-production systems whose pieces are connected in a row may not have maintenance scheduling procedures fixed because problems occur at different times (electricity plants, cement plants, water desalination plants). Contemporary software and artificial intelligence (AI) technologies are used to fulfill the research objectives by developing a predictive maintenance program. The data of the fifth thermal unit of the power station for the electricity of Al Dora/Baghdad are used in this study. Three stages of research were conducted. First, missing data without temporal sequences were processed. The data were filled using time series hour after hour and the times were filled as system working hours, making the volume of the data relativel
... Show MoreThe distribution of chilled water flow rate in terminal unit is an important factor used to evaluate the performance of central air conditioning unit. A prototype of A/C unit has been made, which contains three terminal units with a complete set of accessories (3-way valve, 2-way valve, and sensors) to study the effect of the main parameters, such as total water flow rate and chilled water supply temperature with variable valve opening. In this work, 40 tests were carried out. These tests were in two groups, 20 test for 3-way valve case and 20 test for 2-way valve case. These tests were performed at three levels of valve opening, total water flow rate and water supply temperature according to the design matrices establis
... Show MoreCoherent noise such as ground roll and guided wave is present in the seismic line DE21 (East Diwaniya south eastern Iraq) and it obscures seismic signal and degrades from the quality of data. To attenuate the coherent noise from the shot gather and the Stack of the seismic line, AGORA filter was applied in order to obtain the good signal as the hyperbola shape in shot gather and the reflectors will be clearly to interpret it later. It has given good results and the coherent noise was attenuated in high ratio on all the line. The spectrum analysis is confirmed the effectiveness of AGORA filter to attenuate the coherent noise.
The frequency dependent noise attenuation (FDNAT) filter was applied on 2D seismic data line DE21 in east Diwaniya, south eastern Iraq to improve the signal to noise ratio. After applied FDNAT on the seismic data, it gives good results and caused to remove a lot of random noise. This processing is helpful in enhancement the picking of the signal of the reflectors and therefore the interpretation of data will be easy later. The quality control by using spectrum analysis is used as a quality factor in proving the effects of FDNAT filter to remove the random noise.
This study investigated the ability of using crushed glass solid wastes in water filtration by using a pilot plant, constructed in Al-Wathba water treatment plant in Baghdad. Different depths and different grain sizes of crushed glass were used as mono and dual media with sand and porcelaniate in the filtration process. The mathematical model by Tufenkji and Elimelech was used to evaluate the initial collection efficiency η of these filters. The results indicated that the collection efficiency varied inversely with the filtration rate. For the mono media filters the theoretical ηth values were more than the practical values ηprac calculated from the experimental work. In the glass filter ηprac was obtained by multiplying ηth by a facto
... Show MoreThis research includes theoretical and evaluation design of a polarizer filter of high transmission in the near IR region of (900-1200nm) for different incidence angles to obtain a long wave and short wave pass filter using analytical calculations. Results refer to a new configuration design in fewer layers than used in previous studies in the long wave pass at incidence angles (45o,50o,55o). Adopted Hafnium dioxide (HfO2) and Magnesium fluoride (MgF2) as coating material at design wavelength (933nm), the study also included design short wave pass polarizer by using the same coating material.
This study investigated the ability of using crushed glass solid wastes in water filtration by using a pilot plant, constructed in Al-Wathba water treatment plant in Baghdad. Different depths and different grain sizes of crushed glass were used as mono and dual media with sand and porcelaniate in the filtration process. The mathematical model by Tufenkji and Elimelech was used to evaluate the initial collection efficiency η of these filters. The results indicated that the collection efficiency varied inversely with the filtration rate. For the mono media filters the theoretical ηth values were more than the practical values ηprac calculated from
the experimental work. In the glass filter ηprac was obtained by multiplying ηth by a