This paper investigates a new approach to the rapid control of an upper limb exoskeleton actuator. We used a mathematical model and motion measurements of a human arm to estimate joint torque as a means to control the exoskeleton’s actuator. The proposed arm model is based on a two-pendulum configuration and is used to obtain instantaneous joint torques which are then passed into control law to regulate the actuator torque. Nine subjects volunteered to take part in the experimental protocol, in which inertial measurement units (IMUs) and a digital goniometer were used to measure and estimate the torque profiles. To validate the control law, a Simscape model was developed to simulate the arm model and control law in which measurement data from IMUs and a goniometer were fed into the suggested Simscape model. The arm torque profiles are key to the control approach and should be traced by torques produced by the exoskeleton actuators to provide comfort and flexibility for the subjects. A DC motor was used as an actuator for the exoskeleton, and its model was used in the physical Simscape model. To reduce the error in the driving torque compared with the reference arm torque, a PID controller was implemented. The results show the potential of our methodology for tracking and controlling the actuator’s torque, in which the mean square error was reduced to less than 0.2 - a significantly low value.
Discussed the research variables are important, privatization options and strategic analysis of the external environment, and that the purpose of the research is the trade-off between privatization options and choose the most appropriate alternative in proportion to the external environment, the research aims to determine the privatization the most appropriate option for companies and public contracting, showing the importance of the study provide the privatization of public companies as a strategy can all its way public sector organizations from the transfer of work practices or private sector organizations and mechanisms to it as contributing to improving the level of skills Develop the current and future level of performance,
... Show MoreThat internal control is particularly important in improvingperformance and tax reform، they play an important role in the regularity ofwork and development and the anti corruption and activating the decisionsand tax legislation، as contained in the organizational plan and the means،procedures and components designed from which to ensure a policy andimplementation plans The research aims to review the reality of the internalcontrol in the General Commission for Taxes and stand on the deficiencies init, with the strengthening of the role of internal control in the GeneralAuthority for taxes based on the laws and regulations and by using modernmeans to work as well as developing the performance of employees in thebody، including helpin
... Show MoreChaotic features of nuclear energy spectrum in 68Ge nucleus are investigated by nuclear shell model. The energies are calculated through doing shell model calculations employing the OXBASH computer code with effective interaction of F5PVH. The 68Ge nucleus is supposed to have an inert core of 56Ni with 12 nucleons (4 protons and 8 neutrons) move in the f5p-model space ( and ). The nuclear level density of considered classes of states is seen to have a Gaussian form, which is in accord with the prediction of other theoretical studies. The statistical fluctuations of the energy spectrum (the level spacing P(s) and the Dyson-Mehta (or statistics) are well described by the Gaussian orthogonal ens
... Show MoreRecording an Electromyogram (EMG) signal is essential for diagnostic procedures like muscle health assessment and motor neurons control. The EMG signals have been used as a source of control for powered prosthetics to support people to accomplish their activities of daily living (ADLs). This work deals with studying different types of hand grips and finding their relationship with EMG activity. Five subjects carried out four functional movements (fine pinch, tripod grip and grip with the middle and thumb finger, as well as the power grip). Hand dynamometer has been used to record the EMG activity from three muscles namely; Flexor Carpi Radialis (FCR), Flexor Digitorum Superficialis (FDS), and Abductor Pollicis Brevis (ABP) with different le
... Show MoreIn this paper, nanofluid of TiO2/water of concentrations of 0.002% and 0.004% volume was used. This nanofluid was flowing through heat exchanger of shell and concentric double tubes with counter current flow to the hot oil. The thermal conductivity of nanofluid is enhanced with increasing concentrations of the TiO2, this increment was by 19% and 16.5% for 0.004% and 0.002% volume respectively relative to the base fluid (water). Also the heat transfer coefficient of the nanofluid is increased as Reynold's number and nanofluid concentrations increased too. The heat transfer coefficient is increased by 66% and 49% for 0.004% and 0.002% volume respectively relative to the base fluid. This study showed that the friction
... Show MoreRecording an Electromyogram (EMG) signal is essential for diagnostic procedures like muscle health assessment and motor neurons control. The EMG signals have been used as a source of control for powered prosthetics to support people to accomplish their activities of daily living (ADLs). This work deals with studying different types of hand grips and finding their relationship with EMG activity. Five subjects carried out four functional movements (fine pinch, tripod grip and grip with the middle and thumb finger, as well as the power grip). Hand dynamometer has been used to record the EMG activity from three muscles namely; Flexor Carpi Radialis (FCR), Flexor Digitorum Superficialis (FDS), and Abductor Pollicis Brevis (ABP) with different
... Show MoreThe construction of development is required to develop various economic sectors with the necessity to meet the various requirement of both individuals and institutions , or through the import process , which must be commensurate with the needs of the market and the economy and development. But in fact , we found that the process of import in Iraq after 2003 took a turn dangerous excesses on limits of philosophy and objectives of the import , which reflected the level of national production as well as the policy of dumping and given to the lack of matching a lot of goods and materials imported for Standards and Measures of quality and stands behind it causes many of them exposure to the market and weak sectors with an o
... Show MoreThe construction of development is required to develop various economic sectors with the necessity to meet the various requirement of both individuals and institutions , or through the import process , which must be commensurate with the needs of the market and the economy and development. But in fact , we find that the process of import in Iraq after 2003 took a turn dangerous excesses on limits of philosophy and objectives of the import , which is reflected at the level of national production as well as the policy of dumping and given and the lack of matching a lot of goods and materials imported for Standards and Measures of quality and stands behind it causes many of them exposure to the market and weak sectors with an overlap betwee
... Show More