Heat transfer process and fluid flow in a solar chimney used for natural ventilation are investigated numerically in the present work. Solar chimney was tested by selecting different positions of absorber namely: at the back side, front side, and at the middle of the air gap. CFD analysis based on finite volume method is used to predict the thermal performance, and air flow in two dimensional solar chimney under unsteady state condition, to identify the effect of different parameters such as solar radiation. Results show that a solar chimney with absorber at the middle of the air gap gives better ventilation performance. A comparison between the numerical and previous experimental results shows fair agreement.
It is an analytical study carried out at university of Basra using a sample included the dean ,assistants and managers of scientific dept. in the university for about(63)managers .The study aimed at discovering a model of crises management in the university.The researcher adopted the descriptive survey methodology.To achieve the objective of the study ,a questionnaire of (41)statements was developed covering five main variables like ,signal detection, prevention and preparedness, response, recovery and learning .The validity of the questionnaire was done by a group of referees .Its stability was determined by Cronbach,s Alfa .The questionnair,s stability coefficient was(0.
... Show More<p>In the mobile phone system, it is highly desirable to estimate the loss of the track not only to improve performance but also to achieve an accurate estimate of financial feasibility; the inaccurate estimate of track loss either leads to performance degradation or increased cost. Various models have been introduced to accurately estimate the path loss. One of these models is the Okomura / Hata model, which is recommended for estimating path loss in cellular systems that use micro cells. This system is suitable for use in a variety of environments. This study examines the comparison of path loss models for statistical analysis derived from experimental data collected in urban and suburban areas at frequencies of 150-1500 MHz
... Show MoreThe main objective of this study is to describe the preparation of topographic maps using the Surfer software. A total of 159 regularly distributed Ground Control Points (GCPs) were collected with the use of the Differential Global Positioning System (DGPS). Seven methods (Contour Map, Post Map, 3D Surface Map, 3D Wireframe Maps, Grid Vector-1 Map, Color Relief Map, and Shaded Relief Maps) at the Surfer environment were used to prepare the topographic maps at the Mukhtar Village near the Al-Fallujah City. Contour lines with other features were superimposed on the DEM layer, which refers to the topography of the terrain inside this study area. The accuracy of the database's results was estimated, essential maps were given, and the re
... Show MoreFifty three hydatid cysts were collected from different hosts, sheep, goats and cattle , from many slaughterhouse in Salahadin and Baghdad , while human's hydatid cysts samples were collected from Tikrit educational hospital and Tofiqe civilian hospital patients . The study included a biochemical comparison of some hydatid cyst fluid criteria such as, glucose, total protein, pH, glutamate pyrovate transaminase enzyme (GPT) , glutamate oxaloacetate transaminase enzyme (GOT) , acid phosphatase (ACP) , Alkaline Phosphatase (ALP) , and also studied protoscolices viability,the current study showed the differences in chemical composition of hydatid cyst fluids back to host type and parasite strain .
Two‐dimensional buoyancy‐induced flow and heat transfer inside a square enclosure partially occupied by copper metallic foam subjected to a symmetric side cooling and constant heat flux bottom heating was tested numerically. Finite Element Method was employed to solve the governing partial differential equations of the flow field and the Local Thermal Equilibrium model was used for the energy equation. The system boundaries were defined as lower heated wall by constant heat flux, cooled lateral walls, and insulated top wall. The three parameters elected to conduct the study are heater length (7 ≤
Theoretical calculation of the electronic current at N 3 contact with TiO 2 solar cell devices ARTICLES YOU MAY BE INTERESTED IN Theoretical studies of electronic transition characteristics of senstizer molecule dye N3-SnO 2 semiconductor interface AIP Conference. Available from: https://www.researchgate.net/publication/362813854_Theoretical_calculation_of_the_electronic_current_at_N_3_contact_with_TiO_2_solar_cell_devices_ARTICLES_YOU_MAY_BE_INTERESTED_IN_Theoretical_studies_of_electronic_transition_characteristics_of_senstiz [accessed May 01 2023].
Background: The skin functions as a barrier to the external environment, damage to this barrier following a burn disrupts the innate immune system and increases susceptibility to bacterial infection. Objective: This study was carried out to determine the bacterial isolates and study their antimicrobial susceptibility in burned wound infections at one burn's hospital in Baghdad.Type of study:Cross-sectional study.Methods: The bacteria were identified at species level by using Analytic Profile Index (API) system and The antimicrobial susceptibility test was performed according to Kirby-Bauer (disk diffusion) technique.Results: Over a period of one year (from October 2014 to October 2015). Out of 848 patients with different degrees of burns
... Show MoreGas-lift technique plays an important role in sustaining oil production, especially from a mature field when the reservoirs’ natural energy becomes insufficient. However, optimally allocation of the gas injection rate in a large field through its gas-lift network system towards maximization of oil production rate is a challenging task. The conventional gas-lift optimization problems may become inefficient and incapable of modelling the gas-lift optimization in a large network system with problems associated with multi-objective, multi-constrained, and limited gas injection rate. The key objective of this study is to assess the feasibility of utilizing the Genetic Algorithm (GA) technique to optimize t
Sheet piles are necessary with hydraulic structures as seepage cut-off to reduce the seepage. In this research, the computational work methodology was followed by building a numerical model using Geo-Studio program to check the efficiency of using concrete sheet piles as a cut-off or reducer for seepage with time if the sheet piles facing the drawdown technique. Al-Kifil regulator was chosen as a case study, an accurate model was built with a help of observed reading of the measuring devices, which was satisfactory and helped in checking the sheet piles efficiency. Through the study, three scenarios were adopted (with and without) drawdown technique, it was found that at the short time there's no effect of the drawdown technique on