PDBNRSIA Asst, International Journal of Research in Social Sciences and Humanities, 2018
Based on the density functional theory (DFT) , the stability of molecular complexes has been predicted according to hard-soft acid base (HSAB) theory. Relative stability of products and reactivity of soft base sulfide derivatives with halogens (Iodine , Bromine , Chlorine) as soft acid was studied to determine the relative ability of these reactants causing the reaction to be more spontaneous.
DFT at the levels of B3LYP/3-21G and B3LYP/3-21G (d) was used to study HOMO LUMO energy gaps , bonds length and total energy to calculate the softness sequence of each type of acid or base mentioned in this work. All cases studied prove that iodine can be considered as the most softness acid and ethyl methyl sulfide≈ dimethyl sulfide the most
The present study deals with prepositions in the patterns of analytical unite of modern Russian language out of the functional -semantic aspects, which enhances the lexical semantics. The study, also, sheds light on the prepositions of semantic derivation that adds value to the meaning of the unites, promotes the appearance of new forms that match the more important diverse complex analytical unit.
В статье рассмотрены отыменные предлоги в системе литических единиц русского языка с позиций функционального и семантического аспектов. Репрезентирована специфика функциониров
... Show MoreIR spectra of entrance and exit channels of methane and radical oxygen reaction are predicted in the ground state energy. Ab initio calculations at perturbation theory (MP2) with Dunning correction- consistent basis set (aug-cc-pVDZ) have been used. The calculations predicted structures, vibrational frequencies and potential energy surface. Three van der Waals minima from three adiabatic potential energy surfaces have been predicted in entrance and exit channels. Vibration frequency of 3209 cm-1 and 3212 cm-1 of C-H stretching in entrance structures are predicted while O-H vibrational frequency is predicted to be at 3673 cm-1 in the other channel. The lowest energy structure in entrance
... Show MoreIt is very well known in the planning publications that when creating spacing development to a region or sub-region, it can be able to make more than an alternative consisting with the strategic directions overtaken from the actual development of region and the situational and developmental objectives needed. However, the difficulty facing the situational planning is in selecting one of these alternatives to be the best in order to make a balanced situational re-structure, and achieving the economic, social and civil objectives. The developmental situation elements in the regions and governorates, including (Karbala) impose themselves as situational power which implies the process of re-structural arrangement where the situational develo
... Show MoreThe time fractional order differential equations are fundamental tools that are used for modeling neuronal dynamics. These equations are obtained by substituting the time derivative of order where , in the standard equation with the Caputo fractional formula. In this paper, two implicit difference schemes: the linearly Euler implicit and the Crank-Nicolson (CN) finite difference schemes, are employed in solving a one-dimensional time-fractional semilinear equation with Dirichlet boundary conditions. Moreover, the consistency, stability and convergence of the proposed schemes are investigated. We prove that the IEM is unconditionally stable, while CNM is conditionally stable. Furthermore, a comparative study between these two s
... Show MoreExposure of reinforced concrete buildings to an accidental fire may result in cracking and loss in the bearing capacity of their major components, columns, beams, and slabs. It is a challenge for structural engineers to develop efficient retrofitting techniques that enable RC slabs to restore their structural integrity, after being exposed to intense fires for a long period of time. Experimental
investigation was carried out on twenty one slab specimens made of self compacting concrete, eighteen of them are retrofitted with CFRP sheets after burning and loading till failure while three of them (which represent control specimens) are retrofitted with CFRP sheet after loading till failure without burning. All slabs had been tested in a
Test results of nine reinforced concrete one way slab with and without lacing reinforcement are reported. The tests were designed to study the effect of the lacing reinforcement on the flexural response of one way slabs. The test parameters were considered is the lacing steel ratios of (0, 0.0025, 0.0045, and 0.0065), flexural steel ratios of (0.0025, 0.0045, and 0.0065) and span to the effective depth ratios of (11, 13, and 16). Two specimens had no lacing reinforcement and the remaining seven specimens had the lacing reinforcement. Four point bending test were carried out, one of the specimens was tested under the static load applied gradually up to failure and the other specimens were tested under repeated load (5 cyc
... Show MoreThis research presents a numerical study to simulate the heat transfer by forced convection as a result of fluid flow inside channel’s with one-sided semicircular sections and fully filled with porous media. The study assumes that the fluid were Laminar , Steady , Incompressible and inlet Temperature was less than Isotherm temperature of a Semicircular sections .Finite difference techniques were used to present the governing equations (Momentum, Energy and Continuity). Elliptical Grid is Generated using Poisson’s equations . The Algebraic equations were solved numerically by using (LSOR (.This research studied the effect of changing the channel shapes on fluid flow and heat transfer in two cases ,the first: cha
... Show More