Background: Carpal tunnel syndrome (CTS) is the most prevalent upper-limb entrapped neuropathy. A nerve conduction study (NCS) is the simplest method for identifying CTS when combined with a satisfactory clinical assessment and physical assessment. Ultrasound is a beneficial non-traumatic screening approach for CTS and there is a relationship between the NCS tests and the measures of CSA by ultrasound. Objective: to assess whether or not sonographic observations of the median nerve seems to be varied amongst DM and non-DM CTS individual. Patients and methods: The total of 50 non-DM Individuals with CTS and 50 DM individuals with CTS have been included in this study. All individuals were submitted to full medical assessment NCS testing the hands and sonogram US for assessment of cross-sectional area CSA and wrist forearm ratio (WFR). Results: Total 100 affected wrists with CTS are classified as 30 (60.0%) wrists with mild disease, 11 (22.0%) wrists that demonstrated moderate disease and 9 (18.0%) wrists had a severe disease in diabetic CTS patients and 23 (46.0%) wrist mild disease, 20 (40.0%)wrist show moderate disease, 7 (14.0%) wrist had a severe disease in non-diabetic CTS patient. The mean of the median nerve CSA was (0.14+0.03), (0.15+0.04) in diabetic and non-diabetic CTS individuals, respectively with no significant difference between the two groups. In contrast, the wrist-forearm ratio demonstrates a significant difference between the two groups. Conclusion: The CSA of the median nerve is greater in CTS wrists through both DM and non-DM individuals with no significant difference. The mean wrist-forearm ratio was less in diabetic patients than in non-diabetic with a significant difference. Pairing NCS with US imaging gives effective assessment methods for the CTS hands in individuals with and without diabetes.
A thin film of (SnSe) and SnSe:Cu with various Cu ratio (0,3,5 and 7)% have been prepared by thermal evaporation technique with thickness 400±20 nm on glass substrate at (R.T). The effect of Cu dopants concentration on the structural, morphological, optical and electrical properties of (SnSe) Nano crystalline thin films was explored by using X-ray diffraction (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM), energy dispersive spectroscopy (EDS), UV–Vis absorption spectroscopy and Hall Effect measurement respectively. X-ray diffraction analysis reveal the polycrystalline nature of the all films deposited with orthorhombic structure which possess a preferred orientation along the (111) plane. The crystalline sizes o
... Show MoreA lower extracellular pH is one of the few well-documented physiological differences between tumour and normal tissues. On the other hand, elevated glutathione (GSH) level has been detected in many tumours compared with healthy surrounding tissues. The compound II: 3-(9H-purin-6-yl-thio) carbonothionyl methyl-8-oxo-7-(2-thiophen-2-yl) acetamido-5-thia-1-azabicyclo-4-octo-ene-carboxylic acid was a cephalothin derivative contain 6-mercaptopurine (6-MP). Compound II react with general base catalysis in slightly acidic pH or with sulfhydryl nucleophiles to release the chemotherapeutic drug 6-MP. The generation of compound II was accomplished following multistep reaction procedures. The structure of compound II and its intermediate was confir
... Show MoreNovel artificial neural network (ANN) model was constructed for calibration of a multivariate model for simultaneously quantitative analysis of the quaternary mixture composed of carbamazepine, carvedilol, diazepam, and furosemide. An eighty-four mixing formula where prepared and analyzed spectrophotometrically. Each analyte was formulated in six samples at different concentrations thus twentyfour samples for the four analytes were tested. A neural network of 10 hidden neurons was capable to fit data 100%. The suggested model can be applied for the quantitative chemical analysis for the proposed quaternary mixture.
This research is trying to study the Intellectual political structures of the Open Society according to British Thinker –with Austrian origin- Karl Popper (1902-1994). In First Axe we dealt with the context of Open and Closed society in the Popper's thought. While in the Second Axe we studied the Utopian and graduated Engineering. Finally in the third Axe for the Rationalism, Freedom, Individualism, and the Democracy of Equality.
سمير خلف فياض * و محسن طالب د.نوال عزت عبد اللطيف*, مجلة الهندسة والتكنولوجيا, 2010
Background: Surface treatment of machined dental zirconia for enhancement of the adhesion to resin cement, using Er,Cr:YSGG Laser. Materials and Methods: Total number of 42 zirconia disc specimens (9 mm diameter, and 2 mm height) was sintered according to the manufacturer instruction. They are divided into six groups, each group of seven samples. Laser groups (Experiment parameters) were depend on laser total irradiation time, pulse duration, and power. Group (A): 20 sec., 60 µs pulse duration. Group (B): 30 sec., 60 µs pulse duration. Group (C): 40 sec., 60 µs pulse duration. Group (D): 20 sec., 700 µs pulse duration. Group (E): 30 sec., 700 µs pulse duration, with different powers used (1, 1
... Show MoreIbuprofen is one of the most important members of NSAIDs, named aryl propionic acid derivative. Isatin (1H-indole-2,3-dione) is an important molecule of heterocyclic compounds that have many biological activities. This work illustrates the synthesis of new ibuprofen-isatin derivatives by connecting ibuprofen hydrazide with different isatin derivatives by a condensation reaction, followed by characterization by fourier-transform infrared spectroscopy (FTIR) and proton nuclear magnetic resonance (1H-NMR) spectroscopy. The anti-inflammatory activity was evaluated by using the egg-white induce edema method for all the synthesized compounds (5-8), the compounds 5 and 6 showed better anti-inflammatory activity than ibuprofen as a standard
... Show MoreThe main purpose of this work is the construction of an optical parametric amplifier (OPA) to generate a 629 nm pulsed laser. KTP nonlinear crystals were used for both parametric oscillation and amplification. A singly resonant parametric oscillator (OPO) is constructed to generate a signal of 1.54 μm and idler of 3.4 μm when the OPO system is pumped by 1.064 μm Q – switched Nd: YAG laser. The signal was then mixed with the pumping beam in OPA system to form the wanted wavelength. The obtained optical conversion efficiency was 60%.