Preferred Language
Articles
/
qebM1p4BmraWrQ4dSGa2
Robust 3D raspberry-like CdS@MXene heterojunction microsphere reinforced gradient hydrogel-based poly (arylene ether nitrile) membrane with photothermal-catalytic synergy for complex oily emulsified wastewater purification
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Tue Sep 01 2020
Journal Name
Journal Of Ovonic Research
Growth and optoelectronic properties of p-CuO:Al/n-Si heterojunction
...Show More Authors

Scopus (16)
Scopus
Publication Date
Tue Sep 01 2020
Journal Name
Journal Of Ovonic Research
Growth and optoelectronic properties of p-CuO:Al/n-Si heterojunction
...Show More Authors

Publication Date
Sat Jan 01 2022
Journal Name
Ieee Transactions On Robotics
Lidar-Level Localization With Radar? The CFEAR Approach to Accurate, Fast, and Robust Large-Scale Radar Odometry in Diverse Environments
...Show More Authors

View Publication
Scopus (48)
Crossref (44)
Scopus Clarivate Crossref
Publication Date
Tue Jun 01 2021
Journal Name
International Journal Of Nonlinear Analysis And Applications
A proposed method for cleaning data from outlier values using the robust rfch method in structural equation modeling
...Show More Authors

View Publication Preview PDF
Scopus (4)
Scopus
Publication Date
Sun Nov 01 2015
Journal Name
Journal Of Engineering
Treatment of Wastewater Contaminated with Pesticide (Alachlor) by Solar Enhanced Advanced Oxidation Processes
...Show More Authors

The degradation performance of aqueous solution of pesticide Alachlor has been studied at solar pilot scale plant in two photocatalytic systems: homogeneous photocatalysis by photo-Fenton and heterogeneous photocatalysis with titanium dioxide. The pilot scale system included of compound parabolic collectors specially designed for solar photocatalytic applications, and installed at University of Baghdad, Department of Environmental Engineering back yard. The influence of different concentrations, H2O2 (200-2400 mg/l), Fe+2(5- 30 mg/l) and TiO2 (100-500 mg/l) and their relationship with the degradation efficiency were studied.

      The COD removal efficienc

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 01 2022
Journal Name
Environmental Research
Can electrocoagulation technology be integrated with wastewater treatment systems to improve treatment efficiency?
...Show More Authors

View Publication
Scopus (91)
Crossref (85)
Scopus Clarivate Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Environmental Research
Can electrocoagulation technology be integrated with wastewater treatment systems to improve treatment efficiency?
...Show More Authors

Considerable amounts of domestic and industrial wastewater that should be treated before reuse are discharged into the environment annually. Electrocoagulation is an electrochemical technology in which electrical current is conducted through electrodes, it is mainly used to remove several types of wastewater pollutants, such as dyes, toxic materials, oil content, chemical oxygen demand, and salinity, individually or in combination with other processes. Electrocoagulation technology used in hybrid systems along with other technologies for wastewater treatment are reviewed in this work, and the articles reviewed herein were published from 2018 to 2021. Electrocoagulation is widely employed in integrated systems with other electrochemical tech

... Show More
View Publication
Scopus (91)
Crossref (85)
Scopus Clarivate Crossref
Publication Date
Wed Mar 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
REUSE OF DOMESTIC WASTEWATER FOR IRRIGATION: CONCEPTUAL AND BASIC DESIGN ELEMENTS
...Show More Authors

In Iraq, water shortages and drought, especially during the hot summer months, necessitates that municipal authorities adopt water reuse projects like reusing treated domestic wastewater for crop irrigation. This work gives the conceptual and basic design elements for the necessary steps of filtration, UV irradiation and chlorination to make such a wastewater fit for agricultural use. A typical rural community of 50,000 people is considered as an example case for which functionality and relative simplicity of the proposed designs are prime factors. The objectives are 1) to show what is required and 2) that the presented information may be utilized to embark on the following phases of detailed design and execution of such projects.

View Publication Preview PDF
Publication Date
Thu Jan 01 2015
Journal Name
Journal Of Engineering
Wastewater Bio-solids Management for Fertilizer Quality Using Co- composting Process
...Show More Authors

Co-composting process can be acquired by combining organic fraction of municipal solid waste (OFMSW) with sewage sludge (SS) and mature compost (MC) as enhancement and bulking agent to overcome the problems of municipal solid waste and wastewater treatment plants besides the finally produced fertilizer usage for agriculture and horticulture. The effects of different mixture ratios of (OFMSW), (SS) and (MC) on the performance of composting process were investigated in this study. Piles of about 10 kg were prepared by mixing OFMSW, SS and MC in three different ratios (w/w) [OFMSW: SS: MC= 3:1:1, 3:2:1, and 3:3:1]. Results showed that the pile [3:1:1] was most beneficial to composting. The final compost products contained a

... Show More
View Publication
Publication Date
Mon Jun 01 2015
Journal Name
Journal Of Engineering
Coagulation - Flotation Process for Removing Oil from wastewater using Sawdust+ Bentonite
...Show More Authors

In many industries especially oil companies in Iraq consumed large quantities of water which will produce oil-contaminated water which can cause major pollution in agricultural lands and rivers. The aim of the present work is to enhance the efficiency of dispersed air flotation technique by using highly effective and cost-efficient coagulant to treating gas oil emulsion. The experimental work was carried out using bubble column made of Perspex glass (5cm I.D, 120cm height). A liquid was at depth of 60cm. Different dosage of sawdust +bentonite at ratio 2:1 (0.5+ 0.25; 1+ 0.5 and 2+1) gm and alum at concentration (10,20and30mg/l) at different pH ( 4 and 7) were used to determine optimum dosages of coagulant. Jar test exper

... Show More
View Publication Preview PDF