Background: This study aimed to apply a high-power pulsed alexandrite laser in vitro, the researchers tested different exposure periods, pulse lengths, and laser fluencies to see which dosage was most successful against S. aureus bacteria, which had developed resistance to many antibiotics. Method: Three bacteria samples were exposed to laser beams for 30 seconds with a 5ms pulse duration and a laser fluency of 5J/cm2. The process was repeated with laser fluencies of 10, 15, and 20. Results: The study was carried out by using different doses of Alexandrite laser. Results: There are significant differences (p = 0.05) in the mean number of bacteria colonies exposed for 30 and 60 seconds at any laser fluencies utilized in the present investigation. Except for the 15 J.cm-2 laser fluency; there was a statistically significant difference (p < 0.001) between 60 sec and 90-sec exposure durations. Conclusion: In conclusion, the exposure periods, pulse durations, and laser fluencies of pulsed alexandrite laser were found to have an influence on the mean colony count of S aureus bacteria and to establish the effective dose.
Objectives To quantify the reproducibility of the drill calibration process in dynamic navigation guided placement of dental implants and to identify the human factors that could affect the precision of this process in order to improve the overall implant placement accuracy. Methods A set of six drills and four implants were calibrated by three operators following the standard calibration process of NaviDent® (ClaroNav Inc.). The reproducibility of the position of each tip of a drill or implant was calculated in relation to the pre-planned implants’ entry and apex positions. Intra- and inter-operator reliabilities were reported. The effects of the drill length and shape on the reproducibility of the calibration process were also investig
... Show MoreThe nuclear structure of some cobalt (Co) isotopes with mass number A=56-60 has been studied depending on the effect of some physical properties such as the electromagnetic properties effects, such as, elastic longitudinal form factors, electric quadrupole moments, and magnetic dipole moments. The fp model space is used to present calculations using GXFP1 interaction by adopting the single particle wave functions of the harmonic oscillator. For all isotopes under consideration, the 40Ca nucleus is regarded as an inert core in fp model-space, while valence nucleons are moving through 1f7/2, 2p3/2, 1f5/2, and 2p1/2 orbits. The effects of core-polarization are obtained by the first orde
... Show MoreDuring the prior three decades numerous research works presented to investigate the behavior of reinforced soil. A, IJSR, Call for Papers, Online Journal
An analytical form of the ground state charge density distributions
for the low mass fp shell nuclei ( 40 A 56 ) is derived from a
simple method based on the use of the single particle wave functions
of the harmonic oscillator potential and the occupation numbers of
the states, which are determined from the comparison between theory
and experiment.
For investigating the inelastic longitudinal electron scattering form
factors, an expression for the transition charge density is studied
where the deformation in nuclear collective modes is taken into
consideration besides the shell model space transition density. The
core polarization transition density is evaluated by adopting the
shape of Tass
Background: The systemic host modulation therapy is new approach in treatment of periodontal diseases. Materials and methods:The target of this treatment is the host response to microbial infection because at present time,it is well known that most of damage found in periodontal diseases cause by the inflammatory -immune response to periodontal infections.Sub-antimicrobial-dose Doxycycline (SDD) is a 20-mg dose of Doxycycline (Periostat) that is approved and indicated as an adjunct to scaling and root planning (SRP) in the treatment of chronic periodontitis. Results:At present, SDD (Periostat) is the only systemically administered agent that is approved by the U.S. Food and Drug Administration (FDA) and accepted by the American Dental Asso
... Show MorePolyaniline polymer has been prepared by chemical oxidation
polymerization method in laboratory successfully. The PANI and
(PVA+PVP) as a polymer blends in different percentage (30%, 50%,
70%) from Polyaniline was prepared. The sample was studies as
optical properties by UV-vis spectrophotometer at (400-700) nm.
The result of optical energy gap was 2.23 eV for pure (PVA+ PVP)
and with additive was increasing with increasing PANI concentration
to become (2.49 for 30% to 2.52 for 70%) PANI. The goal of this
project is prepare triple blend polymer and study the effect when add
conductive polymer (Polyaniline) on the optical properties and
calculate optical constant as energy gap, refractive index, dielectric