Preferred Language
Articles
/
qBcTVI8BVTCNdQwCeGyC
Mutations in ergosterol 11 gene of fluconazol resistant candida albicans isolated from different clinical samples
...Show More Authors

Fluconazole was used to test the susceptibility of Candida albicans isolated from different clinical samples, and to detect mutations in ERG11 gene, and their relationship to fluconazole resistance. Forty-eight isolates of Candida albicans were tested for susceptibility using the disc diffusion method (M-44). ERG11 genes of six isolates were amplified (four resistant, two susceptible) and sequenced. The sequenced genes were analyzed to detect the mutations. Out of 48 isolates of Candida albicans, 4 (8%) were resistant to fluconazole. Sixteen-point mutations were detected included 13 silent mutations, and three missense mutations. The mutations of A945C (E266D) and G1609A (V488I) were found only in susceptible Candida albicans isolates, while the mutation of G1456A (V437I) was detected only in resistant Candida albicans isolates. Candida albicans had a high susceptibility against fluconazole. The amino acid substitutions of E266D and V488I have no role in fluconazole resistance, while the substitution of V437I may have a role in developing resistance against fluconazole. Multiple point mutations in ERG11 gene may develop resistance to fluconazole.

Scopus
Preview PDF
Quick Preview PDF
Publication Date
Wed Jun 30 2021
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Advanced Study of Promoted Pt /SAPO-11 Catalyst for Hydroisomerization of the n-Decane Model and Lube Oil
...Show More Authors

   SAPO-11 is synthesized from silicoaluminophosphate in the presence of di-n-propylamine as a template. The results show that the sample obtained has good crystallinity, 396m2/g BET surface area, and 0.35 cm3/g pore volume. The hydroisomerization activity of (0.25)Pt (1)Zr (0.5)W/SAPO-11 catalyst was determined using n-decane and base oil. All hydroisomerization experiments of n-decane were achieved at a fixed bed plug flow reactor at a temperature range of 200-275°C and  LHSV 0.5-2h-1.  The results show that the n-decane conversion increases with increasing temperature and decreasing LHSV, the maximum conversion of 66.7 % was achieved at temperature 275°C and LHSV of 0.5 h-1

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Feb 06 2019
Journal Name
National Academy Science Letters
The Detection Limit of PCR Amplification for Cryptosporidium spp. Oocysts in Fecal Samples
...Show More Authors

View Publication
Scopus (3)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Thu Aug 01 2024
Journal Name
Indonesian Journal Of Chemistry
Cloud Point Extraction Method for Spectrophotometric Determination of 3-Aminophenol in Environmental Samples
...Show More Authors

This work describes the development of new spectrophotometric techniques for 3-aminophenol assessment. The first technique involves using benzidine in an alkaline solution to convert 3-aminophenol into a colored complex. The produced complex has a red color with an absorbance of 462 nm. Between the concentration range 5–14 μg mL−1, Beer's law is obeyed with a correlation coefficient (R2) of 0.99781, a limit of detection (LOD) of 0.0423 μg mL−1, and a limit of quantification (LOQ) of 0.1411 μg mL−1. The recovery was between 87.2–95.43%, the relative standard deviation (%RSD) was 2.40–3.31% and the molar absorptivity was 3.545 × 103 L mol−1 cm−1. Secondly, cloud point extraction (CPE) was used to determ

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Fri Sep 25 2020
Journal Name
International Journal Of Drug Delivery Technology
Simultaneous Determination of Trace Mefenamic Acid in Pharmaceutical Samples via Flow Injection Fluorometry
...Show More Authors

Mefenamic acid belongs to non-steroidal anti-inflammatory drugs that are used widely for the treatment of analgesia. Our aim from this study is to establish a new assay for the quantitative determination of mefenamic acid (MFA) in the pharmaceutical sample by two sensitive and rapid flow injection-fluorometric methods. A homemade fluorometer was used in fluorescence measurements, which using solid-state laser diode 405 and 532 nm as a source, combined with a continuous flow injection technique. The first method depends on the effect of MFA on calcein blue (CLB) fluorescence at 405 nm. Another method is a study of rhodamine-6G (Rh-6G) fluorescence after adding MFA, and recording at 532 nm. Optimum parameters as fluorescent dye concen

... Show More
View Publication
Scopus (8)
Crossref (5)
Scopus Crossref
Publication Date
Sun Jun 03 2018
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Sulphite in Various Water Samples Via Chromium-1,5-Diphenylcarbazide Complex
...Show More Authors

A simple and rapid spectrophotometric method for the determination of sulphite SO3-2 is described. The method is based on the rapid reduction of known amount of chromate CrO4-2 in the presence of sulphite in acidic medium of 2N H2SO4. The amount of excess of chromate was measured after it reactions with 1,5-diphenylcarbazide which finally gives a pink-violet, water soluble and stable complex, which exhibit a maximum absorption at 542 nm. Beer's law was obeyed in the concentration range from 0.004-6.0 µg of sulphite in a final volume of 25 ml with a molar absorbtivity of 4.64×104 l.mol-1.cm-1, Sandal's sensitivity index of 0.001724 ?g .cm-2 and relative standard deviation of ±0.55 - ±0.83 depending on the concentration level. The present

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
A sensitive spectrophotometric determination of tadalafil in pharmaceutical preparations and industrial wastewater samples
...Show More Authors

A simple, accurate, precise, rapid, economical and a high sensitive spectrophotometric method has been developed for the determination of tadalafil in pharmaceutical preparations and industrial wastewater samples, which shows a maximum absorbance at 204 nm in 1:1 ethanol-water. Beer's law was obeyed in the range of 1-7?g/ mL ,with molar absorptivity and Sandell ? s sensitivity of 0.783x105l/mol.cm and 4.97 ng/cm2respectively, relative standard deviation of the method was less than 1.7%, and accuracy (average recovery %) was 100 ± 0. 13. The limits of detection and quantitation are 0.18 and 0.54 µg .ml-1, respectively. The method was successfully applied to the determination of tadalafil in some pharmaceutical formulations

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Measuring Uranium Concentrations in Soil Samples of Midland Refineries Company - Doura - Baghdad – Iraq
...Show More Authors

      In this study, the CR-39 detector technique was used, to estimate the uranium concentration from the soil in midland refineries Company (Doura refine (, Baghdad, Iraq. Uranium concentrations in soil samples have been measured using solid state nuclear track detector type CR-39.  Nine soil samples were collected from different areas within the Doura refinery and other soil samples were collected form Abu Tayara Street and ALshortaa District outside the refinery for comparison. The results showed variable values for uranium concentrations. The average value of uranium concentration was found to be 0.37 ppm in doura refinery. For areas outside the refinery, the concentration of uranium was 0.008 ppm. Thes

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Oct 15 2023
Journal Name
Bionatura
Study the effect of the different doses from the laser on Staphylococcus aureus Bacteria growth in vitro
...Show More Authors

Background: Laser is a novel physical therapy technique used to treat various conditions, including wound healing, inhibition of bacterial growth, and postoperative wounds. High-power pulsed alexandrite laser therapy is one of the most prevalent forms of laser therapy, which is a noninvasive method for treating various pathological conditions, thereby enhancing functional capacities and quality of life. It is a modern medical and physiotherapeutic technology. Generally, the Alexandrite laser emits infrared light with a wavelength of 755 nm, allowing it to propagate and penetrate tissues. Objective: This study focused on the application of a high-power pulsed alexandrite laser in vitro to evaluate the effect of a pulsed alexandrite l

... Show More
View Publication
Crossref (1)
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Plant Archives
Assessment of organic carbon content in different topographic from northern Iraq using remote sensing technique and GIS
...Show More Authors

Scopus (2)
Scopus
Publication Date
Wed Jun 17 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of metal ions release and corrosion potential from different bracket archwire combinations (An in vitro study)
...Show More Authors

Background: Esthetic treatment is the options of patient seeking orthodontic treatment. Therefore this study was conducted to measure the concentration of Aluminum, Nickel, Chromium and Iron ions released from combination of monocrysralline brackets with different arch wires immersed in artificial saliva at different duration, to evaluate the corrosion point on different parts of the orthodontic appliances before and after immersion in artificial saliva, and to evaluate the corrosion potential of each group of the orthodontic appliances. Material and methods: Eighty orthodontic sets prepared. Each set represents half fixed orthodontic appliance, from the central incisor to the first molar, for the maxillary arch, each set consisted of molar

... Show More
View Publication Preview PDF