Preferred Language
Articles
/
pxf_LZIBVTCNdQwCw6fp
Poly-Ether-Ether-Ketone versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 2: periodontal health and microbial biofilm assessment
...Show More Authors
Abstract<sec> <title>Background

Retainers have the potential to detrimentally impact periodontal health and contribute to tooth decay.

Objectives

To investigate periodontal health and bacterial biofilm related to Poly-Ether-Ether-Ketone (PEEK) fixed retainers as compared to Dead-soft coaxial fixed retainer (DSC).

Trial design

A two-arm parallel groups single-centre randomized clinical trial.

Methods

The trial included patients whose orthodontic treatment was completed and required retainers. Participants were randomly assigned into two retainer groups: PEEK retainers, prepared by computer-aided design and manufacturing into 0.8 mm wire form, and DSC retainers. The objectives included assessing periodontal health through plaque accumulation index (PI), bleeding on probing (BOP), periodontal pocket depth (PPD), gingival index (GI), calculus index (CI), and alveolar bone height (ABH) assessment. Biofilm assessment involved bacteriological screening of aerobic, facultative anaerobic, mutans streptococci, and lactobacilli. The periodontal indices and microbiological screening as well as were assessed at the debonding stage (T0), 1-month (T1), 3-month (T3), and 6-month (T6) after the commencement of the trial, except for the ABH, which was recorded using periapical radiograph at T0 and T6.

Blinding

Single blinding of participants in addition to the bacteriological specialist.

Results

Initially, the trial enrolled 46 participants, aged between 12 and 28 years, and were randomly assigned to two groups, with 23 participants in each group. Subsequently, one participant withdrew from the trial, resulting in a total of 45 participants whose data were analysed. Assessment of the periodontal indices, excluding the CI (P = .480), revealed statistically but not clinically significant differences between groups after 6-month of retention (P = .016 of PI, P = .020 of BOP, P = .05 of PPD, and P = .01 of GI). There was slight plaque accumulation, normal PPD (approximately 1 mm), healthy to mild gingivitis with a GI of less than 1 and BOP was around 10%. Concerning the ABH, there was a noticeable reduction in its score after 6 months, particularly in the PEEK group, although the difference was not statistically significant (P = .102). Furthermore, the bacteriological viable count did not show any significant difference between the groups during the recall visits.

Harms

There have been no reported negative consequences.

Limitations

Blinding the assessor of periodontal indices was not feasible due to the nature of the intervention. The trial follow-up duration was limited.

Conclusions

Both the PEEK and DSC retainers have comparable impacts on periodontal health and bacterial accumulation and composition during the retention period.

Trial registration

NCT05557136.

Scopus Clarivate Crossref
View Publication
Publication Date
Mon Jun 22 2020
Journal Name
Baghdad Science Journal
Studying the Effect of Magnesium Oxide Nanoparticles Prepared on the Surface of Poly Methyl Methacrylate
...Show More Authors

          In this paper, magnesium oxide nanoparticles (MgO NPS) have been prepared and characterized and its concentration effect has been studied on polymers surface (MgO NPS). The results showed that the degradation of poly methyl methacrylate increased when using such metal oxide. The results also showed that the metal oxide increased the degradation of poly methyl methacrylate. X-ray diffraction, scanning electron microscopy, atomic force microscopy were used to study the morphological characteristics and size of nano MgO particles analysis.  Films were prepared by mixing the different masses of MgO NPS (0.025, 0.05, 0.1, 0.2 and 0.4) % with a polymer solution ratio (W/V) 7 %. Photo-

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Baghdad Science Journal
Natural Pigment –Poly Vinyl Alcohol Nano composites Thin Films for Solar Cell: nanocomposites thin film
...Show More Authors

Solar cells thin films were prepared using polyvinyl alcohol (PVA) as a thin film, with extract of natural pigment from local flower. A concentration of 0.1g/ml of polyvinyl alcohol solution in water was prepared for four samples, with various concentrations of plant pigment (0, 15, 25 and 50) % added to each of the four solutions separately for preparing (PVA with low concentrated dye , PVA with medium concentrated dye and PVA with high concentrated dye ) thin films respectively . Ultraviolet absorption regions were obtained by computerized UV-Visible (CECIL 2700). Optical properties including (absorbance, reflectance, absorption coefficient, energy gap and dielectric constant) via UV- Vis were tested, too.  Fourier transform infra

... Show More
View Publication Preview PDF
Scopus (28)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Fri Aug 15 2025
Journal Name
Baghdad Science Journal
Corrosion Protection of Copper in Salt Medium by Poly 4-Hyroxyaniline Deposited via Electrodeposition Technique
...Show More Authors

The polymer was used to inhibit the corrosion of copper metal in salt media in different concentrations at room temperature using potentiometric polarization measurement. The polymer was prepared by mixing (0.1 M) 4-Hydroxy aniline (C6H7NO) with (0.25M) of ammonium persulfate as the initiator using the electro-deposition technique. The polymer’s results showed that copper in (3.5%) NaCl had good corrosion resistance. The findings demonstrate that the %IE for polymer-induced copper corrosion is 89.32% at 10 ppm concentration as a result of the 4-hydroxy aniline polymer’s adsorption from salt solution on the surface of copper metal. The numbers from the polarization method and the acquired standard data agree well. The coated copper by po

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Aug 15 2025
Journal Name
Baghdad Science Journal
Corrosion Protection of Copper in Salt Medium by Poly 4-Hyroxyaniline Deposited via Electrodeposition Technique
...Show More Authors

The polymer was used to inhibit the corrosion of copper metal in salt media in di erent concentrations at room temperature using potentiometric polarization measurement. The polymer was prepared by mixing (0.1 M) 4-Hydroxy aniline (C6H7NO) with (0.25M) of ammonium persulfate as the initiator using the electro-deposition technique. The polymer’s results showed that copper in (3.5%) NaCl had good corrosion resistance. The ndings demonstrate that the %IE for polymer-induced copper corrosion is 89.32% at 10 ppm concentration as a result of the 4-hydroxy aniline polymer’s adsorption from salt solution on the surface of copper metal. The numbers from the polarization method and the acquired standard data agree well. The coated copper by poly

... Show More
Scopus Crossref
Publication Date
Mon Jun 08 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of en-masse retraction using microimplant versus conventional techniques: An in vitro study
...Show More Authors

Background: The study aimed to investigate the effect of different techniques of en masse retraction on the vertical and sagittal position, axial inclination, rate of space closure, and type of movement of maxillary central incisor. Materials and methods: A typodont simulation system was used (CL II division 2 malocclusion). Three groups were used group 1(N=10, T-loop), group 2(N=10, Time-Saving loop), and group 3(N=10, Microimplant). Photographs were taken before and after retraction and measurements were made using Autodesk AutoCAD© software 2010. Kruskal-Wallis one-way analyses of variance and Mann-Whitney U test (p?0.05) were used. Results: The rate of space closure showed no significant difference among the three groups (p?0.05), whi

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 01 2018
Journal Name
European Journal Of General Medicine
The Value of Longitudinal Strain versus Coronary Angiography in Detection of Coronary Artery Disease
...Show More Authors

Aims: The aim of this study was to evaluate the value and accuracy of longitudinal strain in detection of coronary artery disease compared to coronary angiography. Results: The left ventricular longitudinal strain-speckle tracking showed evidence of stenosis of left anterior descending artery, circumflex artery and right coronary artery in (86.1%), (76.4%), and (84.7%) respectively. For the stenosis in left anterior descending artery, the current study showed that the longitudinal strain was a good predictor for presence of significant stenosis with a sensitivity of (93.8%), specificity (75%) and accuracy (91.7%) compared with coronary angiography. For the stenosis in right coronary artery, the left ventricular longitudinal strain had

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Medico-legal Update
Flexible ureterorenoscopy versus extracorporeal shock wave lithotripsy for treatment of lower pole renal stones
...Show More Authors

Scopus (1)
Scopus
Publication Date
Sun Apr 20 2025
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Evaluation of Irisin Level in Iraqi Patients with Type 2 Diabetes and Pre-Diabetes Status as a Predictive Factor
...Show More Authors

      The prevalence of diabetes is increasing rapidly and is now recognized as a significant global health problem. Diabetes occurs when a person does not produce enough insulin due to an imbalance in insulin production. This can lead to the failure of organs and tissues such as the kidneys, heart, blood vessels, eyes, nerves, and kidneys. As a result, early diagnosis and classification of type 2 diabetes mellitus (T2DM) are critical to aiding physician assessments. Subsequently, the current study aims to determine irisin levels in patients with T2DM and pre-DM as early predictors for disease cases. The current study included 138 subjects divided into three groups based on fasting blood glucose (FBG) and glycosylated hemoglobi

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Meta Gene
Evaluation of interleukin-9 serum level and gene polymorphism in a sample of Iraqi type 2 diabetic mellitus patients
...Show More Authors

Background: Diabetic mellitus (DM) is a collection of metabolic disorder identified by hyperglycemia. The heterogeneous etiology includes defects either in insulin secretion, or in insulin action, or the both. In addition to the distraction in carbohydrate, fat and protein metabolism. Inflammatory reaction that caused by many pro-inflammatory cytokines play a central role in the pathogenicity of T2DM, these cytokines can enhance insulin resistance which led to impaired glucose homeostasis. Subjects: The study included 75 patients (38 males and 37 females) suffering from T2DM with age mean ± SE 52.30 ± 1.60, and 70 individuals as healthy controls (35 males and 35 females) with age mean ± SE 48.88 ± 0.64. Evaluation of immunological marke

... Show More
View Publication
Scopus (8)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Mon May 20 2024
Journal Name
International Journal Of Diabetes In Developing Countries
Role of stanniocalcin-1 and proenkephalin-A as novel biomarkers in prediction of newly diagnosed type 2 diabetic patients
...Show More Authors

View Publication
Scopus (4)
Crossref (3)
Scopus Crossref