Poly-Ether-Ether-Ketone versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 2: periodontal health and microbial biofilm assessment
...Show More Authors
Abstract<sec> <title>Background

Retainers have the potential to detrimentally impact periodontal health and contribute to tooth decay.

Objectives

To investigate periodontal health and bacterial biofilm related to Poly-Ether-Ether-Ketone (PEEK) fixed retainers as compared to Dead-soft coaxial fixed retainer (DSC).

Trial design

A two-arm parallel groups single-centre randomized clinical trial.

Methods

The trial included patients whose orthodontic treatment was completed and required retainers. Participants were randomly assigned into two retainer groups: PEEK retainers, prepared by computer-aided design and manufacturing into 0.8 mm wire form, and DSC retainers. The objectives included assessing periodontal health through plaque accumulation index (PI), bleeding on probing (BOP), periodontal pocket depth (PPD), gingival index (GI), calculus index (CI), and alveolar bone height (ABH) assessment. Biofilm assessment involved bacteriological screening of aerobic, facultative anaerobic, mutans streptococci, and lactobacilli. The periodontal indices and microbiological screening as well as were assessed at the debonding stage (T0), 1-month (T1), 3-month (T3), and 6-month (T6) after the commencement of the trial, except for the ABH, which was recorded using periapical radiograph at T0 and T6.

Blinding

Single blinding of participants in addition to the bacteriological specialist.

Results

Initially, the trial enrolled 46 participants, aged between 12 and 28 years, and were randomly assigned to two groups, with 23 participants in each group. Subsequently, one participant withdrew from the trial, resulting in a total of 45 participants whose data were analysed. Assessment of the periodontal indices, excluding the CI (P = .480), revealed statistically but not clinically significant differences between groups after 6-month of retention (P = .016 of PI, P = .020 of BOP, P = .05 of PPD, and P = .01 of GI). There was slight plaque accumulation, normal PPD (approximately 1 mm), healthy to mild gingivitis with a GI of less than 1 and BOP was around 10%. Concerning the ABH, there was a noticeable reduction in its score after 6 months, particularly in the PEEK group, although the difference was not statistically significant (P = .102). Furthermore, the bacteriological viable count did not show any significant difference between the groups during the recall visits.

Harms

There have been no reported negative consequences.

Limitations

Blinding the assessor of periodontal indices was not feasible due to the nature of the intervention. The trial follow-up duration was limited.

Conclusions

Both the PEEK and DSC retainers have comparable impacts on periodontal health and bacterial accumulation and composition during the retention period.

Trial registration

NCT05557136.

Scopus Clarivate Crossref
View Publication
Publication Date
Fri Jun 03 2016
Journal Name
Al-kindy College Medical Journal
Patellar Fracture Fixation by Cerclage and Tension Band Wiring Technique versus Kirschner wires and Tension Band Wiring Technique
...Show More Authors

Background:Fractures of patella constitute 1% of all fractures. Various techniques have been described for internal fixation of patella fractures. Superiority of one technique over the other has long been debated. Objective:We reviewed a series of seventy patients with transverse or comminuted fractures of patella treated with cerclage and tension band wiring technique to assess if it had any advantages over k. wires and tension band wiring technique. Type of the study:Retrospective study.Methods; Seventy patients with displaced patella fracture, with a mean age of 47 years (range 13-75) were divided into two groups :group A 36 patients were treated with cerclageand tensi

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 31 2016
Journal Name
Al-kindy College Medical Journal
Patellar Fracture Fixation by Cerclage and Tension Band Wiring Technique versus Kirschner wires and Tension Band Wiring Technique
...Show More Authors

Background: Fractures of patella constitute 1% of all fractures. Various techniques have been described for internal fixation of patella fractures. Superiority of one technique over the other has long been debated. Objective: We reviewed a series of seventy patients with transverse or comminuted fractures of patella treated with cerclage and tension band wiring technique to assess if it had any advantages over k. wires and tension band wiring technique. Type of the study: Retrospective study. Methods; Seventy patients with displaced patella fracture, with a mean age of 47 years (range 13-75) were divided into two groups :group A 36 patients were treated with cerclage and tension bands technique ,and group B 34 patients were fixed by 2 K.

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Osseointegration & Oral Rehablitation
Evaluation of marginal bone loss around SLActive implants by CBCT using different implant dimensions and surgical approaches: A clinical and radiological prospective study
...Show More Authors

Aim: The reduction in the amount of marginal bone is the most important demand for the long term success of dental implants. This prospective clinical study was aimed to investigate the marginal bone loss of early loaded SLActive implants with different dimensions and surgical approaches. Materials and methods Fifteen patients aged from 18 to 60 years were divided into 2 groups (flapped and flapless approach) that underwent delayed implant placement protocol with SLActive implants. The marginal bone level was estimated by cone-beam computed tomography during three different periods: preoperatively, 8 weeks after surgery and 24 weeks after loading of the prosthesis. Results: The mean value of marginal bone level was not significantly chan

... Show More
View Publication Preview PDF
Scopus (5)
Scopus
Publication Date
Mon Jan 08 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Recurrence Rate of Pleomorphic Adenoma in Minor Salivary Glands After Surgical Excision: A Retrospective Clinical Study
...Show More Authors

Background: Pleomorphic adenoma of the minor salivary gland is a rare benign tumor. It commonly occurs in the hard and soft palates. Treatment by surgical excision achieved success in improving the patient’s health. Objective: To evaluate the recurrence rate after surgical treatment of pleomorphic adenoma in minor salivary glands. Methods: This retrospective study included patients who attended the Maxillofacial Surgery Unit in Ghazi Al-Hariri Hospital, Baghdad, from 2019 to 2021, complaining of soft tissue lumps involving the soft and hard palate, buccal mucosa, and upper lip. After the provisional diagnosis of these lesions, a total surgical excision of the tumor with a safe margin of 1 mm was performed, and the biopsy was sent

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Mon Jan 08 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Recurrence Rate of Pleomorphic Adenoma in Minor Salivary Glands After Surgical Excision: A Retrospective Clinical Study
...Show More Authors

Background: Pleomorphic adenoma of the minor salivary gland is a rare benign tumor. It commonly occurs in the hard and soft palates. Treatment by surgical excision achieved success in improving the patient’s health. Objective: To evaluate the recurrence rate after surgical treatment of pleomorphic adenoma in minor salivary glands. Methods: This retrospective study included patients who attended the Maxillofacial Surgery Unit in Ghazi Al-Hariri Hospital, Baghdad, from 2019 to 2021, complaining of soft tissue lumps involving the soft and hard palate, buccal mucosa, and upper lip. After the provisional diagnosis of these lesions, a total surgical excision of the tumor with a safe margin of 1 mm was performed, and the biopsy was sent for hist

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sun Sep 22 2019
Journal Name
Baghdad Science Journal
Detection of CTX-M-type ESBLs from Escherichia coli Clinical Isolates from a Tertiary Hospital, Malaysia
...Show More Authors

The present study aims to detect CTX-M-type ESBL from Escherichia coli clinical isolates and to analyze their antibotic susceptibility patterns. One hundred of E. coli isolates were collected from different clinical samples from a tertiary hospital. ESBL positivity was determined by the disk diffusion method. PCR used for amplification of CTX-M-type ESBL produced by E. coli. Out of 100 E. coli isolates, twenty-four isolates (24%) were ESBL-producers. E. coli isolated from pus was the most frequent clinical specimen that produced ESBL (41.66%) followed by urine (34.21%), respiratory (22.23%), and blood (19.05%).  After PCR amplification of these 24 isolates, 10 (41.66%) isolates were found to possess CTX-M genes. The CTX-M type ESBL

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Apr 20 2021
Journal Name
Ndian Journal Of Forensic Medicine & Toxicology,
Detection Levels of Cytokines (IL-6 and IL-18) and Microbial Parameters in Patients with Renal Failure in Diyala Province
...Show More Authors

Publication Date
Sun Aug 01 2021
Journal Name
Biochemical & Cellular Archives,
ANTIMICROBIAL ACTIVITY OF CHITOSAN AND/OR GUM ARABIC IN THE LOCAL PRODUCE SOFT AND HARD CHEESE IN BAGHDAD CITY
...Show More Authors

antimicrobial solutions against Coliforms, E. coli O157: H7, yeasts and molds were evaluated by agar well diffusion method. Chitosan (CH) exhibited best antimicrobial activity against the treated microorganisms at concentration of (5%) with contact time for 6hrs at refrigeration temperature (4ÚC), zones of inhibition for (GA) and (CH) for each solution alone ranging from (0 to 10 mm), chitosan solution (CH) exhibited both antibacterial and antifungal activities, Gum Arabic washing solution showed significant antibacterial activity (P < 0.05) against the microorganisms at concentration (15%), without inhibitory effect against E. coli O157:H7 at concentration (10%), in the current study the results confirmed that (15%) (w/v) of GA and 5%

... Show More
Scopus (1)
Scopus
Publication Date
Sun Mar 10 2013
Journal Name
Journal Of Life Sciences And Technologies
Synthesis, Characterization, and Anti-Microbial Study of Metal Complexes of Polycyclicacetal derived from PVA & Erythro-Ascorbic acid derivative
...Show More Authors

The aim of this work is the synthesis of new grafted PVA polymer with a derivative of Erythro-ascorbic acid (pentulosono-ɣ -lactone-2, 3-enedianisoate). All synthesized compounds were characterized by thin layer chromatography (TLC) and FTIR spectra and aldehyde was also characterized by (U.V-Vis), 1HNMR, 13CNMR and mass spectra. They were also evaluated for antimicrobial properties by dilute method against four pathogenic bacteria (Escherichia coli ,Klebsiella pneumonae, Staphylococcus aureus, Staphylococcus Albus) and two fungal (Aspergillus Niger, Yeast). All polymer metal complexes showed good activities against the various microbial isolates. The polymer metal complexes showed higher activity than the free polymer. The order of increa

... Show More
Preview PDF
Publication Date
Thu Oct 20 2022
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Study the Efficiency of Poly Nicotine Amide as Anticorrosion Coating on Stainless Steel and Study Its Biological Activity
...Show More Authors

Using an electrochemical polymerization technique at room temperature, poly nicotine amide (PNA) was produced from the monomer nicotine amide (NA) in aqueous solution. The structure of polymer layer generated on the stainless steel surface (316 L) (working electrode) is investigated by Fourier Transmission Infrared Region (FT-IR). The anti-corrosion activity of polymer coating on the stainless steel (SS 316 L) is investigated by electrochemical polarization in 0.20M solution of HCl at 293-323K. The graphene -modified polymer film-coated SS had greater protection efficiency (PE percent) when compared to Nano ZnO -modified polymer film-coated SS. For the corrosion process of SS 316 L, kinetic and thermo-dynamic parameters of activatio

... Show More
View Publication
Crossref (1)
Crossref