Preferred Language
Articles
/
pxd-qJEBVTCNdQwCapda
Consequence of violet laser irradiation on the optical properties of mawsoniteCu6Fe2SnS8 [CFTS] thin films deposited via semi-computerized spray pyrolysis technique
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Wed Jul 02 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of addition of hydroxyapatite microscopic fillers on surface roughness and some mechanical properties of heat cured acrylic resin
...Show More Authors

Background: this study aimed to evaluate the effect of addition of hydroxyapatite micro filler in three concentrations (5%, 10%, 15%) on surface roughness, impact strength, flexural strength and hardness. Material and methods: One hundred sixty acrylic samples were used in this study,40 samples were used for each test(impact strength ,flexural strength ,hardness and surface roughness).The test group divided into four subgroups(n=10) for controlgroup,5%,10% ,15%H,A.concentration addition groups .Impact testing device, flexural strength testing device, shore hardness tester and profilometer device were used to measure the four tests examined in this study. Results: the results showed a significant increase in impact strength, hardness in all

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 02 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of addition of untreated and oxygen plasma treated polypropylene fibers on some properties of heat cured acrylic resin
...Show More Authors

Background: The polymethyl methacrylate is the most reliable material for the construction of complete and partial dentures, despite satisfying esthetic demand itsuffered from having unsatisfactory properties like impact strength and transverse strength. This study was designed to improve the impact strength and transverse strength of heat cure acrylic resin by adding untreated and oxygen plasma treated polypropylene fibers and investigate the effect of this additive on some properties of acrylic resin materials. Materials and methods: Untreated and oxygen plasma treated polypropylene fibers was added to PMMA powder by weight 2.5 %. Specimens were constructed and divided into 5 groups according to the using tests; each group was subdivided

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 02 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The influence of adding of modified ZrO2-TiO2 nanoparticles on certain physical and mechanical properties of heat polymerized acrylic resin
...Show More Authors

Background: The mechanical and physical properties of Polymethyl methacrylate (PMMA) don’tfulfill the entire ideal requirements of denture base materials. The purpose of this study was to produce new modified polymer nanocomposite (PMMA /ZrO2-TiO2) andassess itsimpact strength, transverse strength and thermal conductivity in comparison to the conventionalheat polymerized acrylic resin. Materials and Methods: Both ZrO2 and TiO2nano fillers were silanized with TMSPM (trimethoxysilyl propyl methacrylate) silane coupling agent before beingdispersed by ultrasonication with the methylmethacrylate (monomer) and mixed with the polymer by means of 2% by weight in (1:1) ratio, 60 specimens were constructed by conventional water bath processing

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 02 2023
Journal Name
Journal Of Engineering
The Effect of Using Different Aspect Ratios of Sustainable Copper Fiber on Some Mechanical Properties of High-Strength Green Concrete
...Show More Authors

To achieve sustainability, use waste materials to make concrete to use alternative components and reduce the production of Portland cement. Lime cement was used instead of Portland cement, and 15% of the cement's weight was replaced with silica fume. Also used were eco-friendly fibers (copper fiber) made from recycled electrical. This work examines the impact of utilizing sustainable copper fiber with different aspect ratios (l/d) on some mechanical properties of high-strength green concrete. A high-strength cement mixture with a compressive strength of 65 MPa in line with ACI 211.4R was required to complete the assignment. Copper fibers of 1% by volume of concrete were employed in mixes with four different aspect ratios

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
New Technique for Treatment of the dust accumulation from PV solar panels surface
...Show More Authors

One of the most important problems facing the world today is the energy problem. The solution was in finding renewable energy sources such as solar energy. The solar energy applications in Iraq is facing many problems . One of the most important problems is the accumulation of dust on the solar panels surface which causes decreasing its performance sharply. In the present work, a new technique was presented by using two-axis solar tracking system to reduce the accumulated dust on the solar panel surface and compared it with the fixed solar panels which installed at tilt angles 30° and 45°. The results indicated that the maximum losses of the output power due to accumulation of dust on the fixed solar panels is about 31.4% and 23.1% res

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessing The Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jul 28 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Estimation of the Two Parameters for Generalized Rayleigh Distribution Function Using Simulation Technique
...Show More Authors

     In this paper, suggested formula as well a conventional method for estimating the twoparameters (shape and scale) of the Generalized Rayleigh Distribution was proposed. For different sample sizes (small, medium, and large) and assumed several contrasts for the two parameters a percentile estimator was been used. Mean Square Error was implemented as an indicator of performance and comparisons of the performance have been carried out through data analysis and computer simulation between the suggested formulas versus the studied formula according to the applied indicator. It was observed from the results that the suggested method which was performed for the first time (as far as we know), had highly advantage than t

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Jpras Open
The utility of a novel vacuum-assisted foreign body extraction technique from wounds
...Show More Authors

Retained soft tissue foreign bodies following injuries are frequently seen in the Emergency and Plastic Surgery practice. The patients with such presentations require a watchful and detailed clinical as- sessment to overcome the anticipant possibility of missing them. However, the diagnosis based on the clinical evaluation is usually challenging and needs to be supported by imaging modalities that are suboptimal and may fail in identifying some types of foreign bodies. Owing to that, serious complications such as chronic pain, infection, and delayed wound healing can be faced that necessitate a prompt intervention to halt those detrimental consequences. The classical method of removal is a surgical exploration which is not free of risks.

... Show More
Publication Date
Fri Sep 01 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessing the Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Aug 06 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Measurement Of Organic Concentration in Aldehydes By The Derivative Neutron Activation Analysis Technique
...Show More Authors

The aim of this paper is determine the concentration of the organic oxygen in some organic compounds (Aldehydes ) by the derivative neutron activation analysis technique, and the derivative of the oxygen by the nitrogen equivalent toit and the irradiation of anew sample in flounce (1.73*106  n.cm-2.s-1) by the neutron generator .Then the calculation of the radioactivity which is done by using NaI(Tl) . After that we determine the concentration of nitrogen by calibration curve that includes nitrogen compounds which have apparent chemical and physical characteristics .For comparison the result is done by using keldal method.           

View Publication Preview PDF