Preferred Language
Articles
/
phjCa5QBVTCNdQwC9RbL
Computation of the Relationships of X-ray to Radio Luminosities of a Sample of Starburst Galaxies
...Show More Authors

      The goal of this research is to better understand the physical features of starburst galaxies. Radio and X-ray observations are good for exploring the stuff within the central regions of galaxies.  A galaxy that is undergoing a strong star formation, usually in its central area, is known as a starburst galaxy. This paper provides the results of a statistical analysis of a sample of starburst galaxies. The data used in this research have been collected from NASA Extragalactic Database (NED), and HYPERLEDA. Those data have been used to examine possible luminosity correlations of X-ray to a radio of a sample of starburst galaxies. In this research, statistical software, known as statistic-win-program, has been used to investigate if there is a luminosity correlation between multiple-wavelength bands. The results of the statistical analysis conclude that there is a good correlation between X-ray luminosity and radio luminosity at 1.4GHz where the partial correlation coefficient is (R≈0.53) and slope (0.6±0.12). There is also a good correlation between X-ray luminosity and radio luminosity at 5GHz with a good partial correlation coefficient (R ≈ 0.65) and slope (0.77±0.11).  There are good positive relationships between radio luminosity at (1.4GHz, 5GHz) with infrared and far-infrared luminosities (Log L1.4GHz α log LFIR0.89±0.04 α Log LIR0.9±0.03) with a very strong correlation equal to R=0.9 (Log L5GHz α Log LFIR0.79±0.05 α Log LIR0.81±0.05) with strong correlation R=0.8 both with very high probability level p≈10-7. One of the closest and most ubiquitous correlations known among the global features of local star formation and starburst galaxies is the link between far-infrared (FIR) and radio emission.

Scopus Crossref
View Publication
Publication Date
Sun Aug 21 2022
Journal Name
International Journal Of Health Sciences
Effect of x- ray on the treatment of breast cancer combined with amygdalin and doxorubicin separately
...Show More Authors

Background: Radiation therapy has the ability to destroy healthy cells in addition to cancer cells in the area being treated. However, when radiation combines with doxorubicin, it becomes more effective on breast cancer treatment. Objective: This study aims to clarify the effect of X-ray from LINAC combined with amygdalin and doxorubicin on breast cancer treatment, and the possibility of using amygdalin with X-ray instead of doxorubicin for the breast cancer treatment. Method: Two cell lines were used in this study, the first one was MCF-7 cell line and second one was WRL- 68 normal cell line. These cells were preserved in liquid nitrogen, prepared, developed and tested in the (place). The effect of three x-ray doses combined with a

... Show More
View Publication
Crossref
Publication Date
Wed Jul 17 2019
Journal Name
Aip Conference Proceedings
The correction of the line profiles for x-ray diffraction peaks by using three analysis methods
...Show More Authors

In this study used three methods such as Williamson-hall, size-strain Plot, and Halder-Wagner to analysis x-ray diffraction lines to determine the crystallite size and the lattice strain of the nickel oxide nanoparticles and then compare the results of these methods with two other methods. The results were calculated for each of these methods to the crystallite size are (0.42554) nm, (1.04462) nm, and (3.60880) nm, and lattice strain are (0.56603), (1.11978), and (0.64606) respectively were compared with the result of Scherrer method (0.29598) nm,(0.34245),and the Modified Scherrer (0.97497). The difference in calculated results Observed for each of these methods in this study.

View Publication
Scopus (11)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Mon Oct 30 2017
Journal Name
International Journal Of Science And Research
Measurements of X-Ray Dose Delivered at Different Depths Applied on Water Phantom
...Show More Authors

Background: Radiotherapy, is therapy using ionizing radiation in order to deliver an optimal dose of either particulate or electromagnetic radiation to a particular area of the body with minimal damage to normal tissues. The source of radiation may be outside the body of the patient (external beam irradiation) or it may be an isotope that has been implanted or instilled into abnormal tissue or a body cavity. Called also radiotherapy. The aim of work studies the relationship between the depth dose and the high photon xray energies (6MeV and 10MeV). Patients and methods: in our work, we studied the dose distribution in water phantom given at different depths (zero-18) cm deep at1cm intervals treated with different field size (5×5-,10×1

... Show More
Publication Date
Wed May 10 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
X-ray Data and Transition Temperature Measurements of Ca Doped Bi2Sr2La2Cu3O10+δ Superconductor
...Show More Authors

We studied the effect of Ca- doping on the properties of Bi-based superconductors by
adding differ ent amounts of CaO
to the Bi
2
Sr2La2-xCaxCu3O10+δ
compound. consequently, we
obtained three samples A,B and C with x=0.0, 0.4 and 0.8 respectively. The usual solid-state
reaction method has been applied under optimum conditions. The x-ray diffraction analy sis
showed that the samples A and B have tetragonal structures conversely the sample C has an
orthorhombic structure. In addition XRD analysis show that decreasing the c-axis lattice
constant and thus decreasing the ratio c/a for samples A,B and C resp ectively. The X-ray
florescence proved that the compositions of samples A,B and C with the ra

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 01 2008
Journal Name
Iraqi Journal Of Physics
The Determination of Lower Limit Detection of X-Ray Fluorescence for Zinc Powder Suspended in Engine Oil
...Show More Authors

In this work Different weight of pure Zinc powder suspended particles in 4ml base engine Oil were used.
Intensity of Kα Line was measured for the suspended particles ,also for mixture which consist from Zinc particle blended with Engine base Oil. Calibration Curve was drawn between Ikα line Intensity and Zinc concentration at different operation condition. The Lower Limit detection (LLD) and Sensitivity (m) of Spectrometer were determined for different Zinc Concentration (Wt%). The results of LLD and m for Samples were analyzed at Operation Condition of 30KV,17mA is best from Samples were analyzed at Operation Condition of 25KV,15mA

View Publication Preview PDF
Publication Date
Fri Apr 21 2023
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees22fr
Study of the x-ray diffraction lines of calcium titanate nanoparticle using SSP method and Scherrer method
...Show More Authors

In this study, the modified size-strain plot (SSP) method was used to analyze the x-ray diffraction lines pattern of diffraction lines (1 0 1), (1 2 1), (2 0 2), (0 4 2), (2 4 2) for the calcium titanate(CaTiO3) nanoparticles, and to calculate lattice strain, crystallite size, stress, and energy density, using three models: uniform (USDM). With a lattice strain of (2.147201889), a stress of (0.267452615X10), and an energy density of (2.900651X10-3 KJ/m3), the crystallite was 32.29477611 nm in size, and to calculate lattice strain of Scherrer (4.1644598X10−3), and (1.509066023X10−6 KJ/m3), a stress of(6.403949183X10−4MPa) and (26.019894 nm).

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Wed Nov 08 2023
Journal Name
Technologies And Materials For Renewable Energy, Environment, And Sustainability: Tmrees23fr
Studying the relationship between the number of unit cells and the dislocation density of a crystal through the x-ray diffraction pattern of barium oxide nanoparticles
...Show More Authors

In this research, the X-ray diffraction pattern was used, which was obtained experimentally after preparation of barium oxide powder. A program was used to analyze the X-ray diffraction lines of barium oxide nanoparticles, and then the particle size was calculated by using the Williamson-Hall method, where it was found that the value of the particle size is 25.356 nm. Also, the dislocation density was calculated, which is equal to1.555 x1015 (lines/nm2), and the value of the unit cell number was also calculated, as it is equal to 23831.

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
3rd International Scientific Conference Of Alkafeel University (iscku 2021)
Analysis of X-ray diffraction lines profile of Tio2 nanoparticles to determine the energy per unit volume and stress by using Halder-Wagner method
...Show More Authors

In this study, the Halder-Wagner method was used for an analysisX-ray lines of Tio2 nanoparticles. Where the software was used to calculate the FWHM and integral breath (β) to calculate the area under the curve for each of the lines of diffraction. After that, the general equation of the halder- Wagner method is applied to calculate the volume (D), strain (ε), stress (σ), and energy per unit(u). Volume (β). Where the value of the crystal volume was equal to (0.16149870 nm) and the strain was equal to (1.044126), stress (181.678 N / m2), and energy per unit volume (94.8474 J m-3).The results obtained from these methods were then compared with those obtained from each of the new paradigm of the HalderWagner method, the Shearer developm

... Show More
View Publication
Scopus Crossref
Publication Date
Tue Dec 15 2020
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees20
A comparative study of Williamson-Hall method and size-strain method through X-ray diffraction pattern of cadmium oxide nanoparticle
...Show More Authors

In this research, the Williamson-Hall method and of size-strain plot method was employed to analyze X- ray lines for evaluating the crystallite size and lattice strain and of cadmium oxide nanoparticles. the crystallite size value is (15.2 nm) and (93.1 nm) and lattice strain (4.2 x10−4 ) and (21x10−4) respectively. Also, other methods have been employed to evaluate the crystallite size. The current methods are (Sherrer and modified Sherrer methods ) and their results are (14.8 nm) and (13.9nm) respectively. Each method of analysis has a different result because the alteration in the crystallite size and lattice strain calculated according to the Williamson-Hall and size-strain plot methods shows that the non-uniform strain in nan

... Show More
View Publication
Scopus (23)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Thu Dec 28 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Determining the Concentrations of Elements in Tobacco Selected in Iraqi Markets Using X-Ray Fluorescence Technique
...Show More Authors

  X-rays fluorescence technology was used  to measure the concentrations of trace and toxic elements in tobacco smoke. One sample local and eight samples were imported selected from Iraqi markets. The results proved that tobaccos contain few concentrations of element (calcium, potassium, sodium, manganese, magnesium, chlorine, and sulfur), trace concentrations of element (aluminum, vanadium, iron, cobalt, nickel, copper and zinc), and toxic concentrations of element (arsenic, selenium, bromine, antimony, cadmium, mercury and lead). Results are proved the concentrations of elements of samples are lower levels with the other countries in few element like (calcium, potassium, sodium and manganese), while the other elements were hi

... Show More
View Publication Preview PDF
Crossref