The goal of this research is to better understand the physical features of starburst galaxies. Radio and X-ray observations are good for exploring the stuff within the central regions of galaxies. A galaxy that is undergoing a strong star formation, usually in its central area, is known as a starburst galaxy. This paper provides the results of a statistical analysis of a sample of starburst galaxies. The data used in this research have been collected from NASA Extragalactic Database (NED), and HYPERLEDA. Those data have been used to examine possible luminosity correlations of X-ray to a radio of a sample of starburst galaxies. In this research, statistical software, known as statistic-win-program, has been used to investigate if there is a luminosity correlation between multiple-wavelength bands. The results of the statistical analysis conclude that there is a good correlation between X-ray luminosity and radio luminosity at 1.4GHz where the partial correlation coefficient is (R≈0.53) and slope (0.6±0.12). There is also a good correlation between X-ray luminosity and radio luminosity at 5GHz with a good partial correlation coefficient (R ≈ 0.65) and slope (0.77±0.11). There are good positive relationships between radio luminosity at (1.4GHz, 5GHz) with infrared and far-infrared luminosities (Log L1.4GHz α log LFIR0.89±0.04 α Log LIR0.9±0.03) with a very strong correlation equal to R=0.9 (Log L5GHz α Log LFIR0.79±0.05 α Log LIR0.81±0.05) with strong correlation R=0.8 both with very high probability level p≈10-7. One of the closest and most ubiquitous correlations known among the global features of local star formation and starburst galaxies is the link between far-infrared (FIR) and radio emission.
The actual observations for Jupiter radio storm were taken for Hawaii station within multi years from 2001 to 2012. The Central Meridian Longitude (CMLІІІ) and Io's phase (γIo) were calculated for each year from Radio Jove program, the results of CMLІІІ for year 2006 was A=(180-300)º,B=(15-239)º, C=(60-280)º, phase was A=(182-260)º,B=(40-109)º, C=(200-260)º, which were close to the theoretical values, longitude was A=(180-300)º, B=(15-240)º, C=(60-280)º and phase was A=(180-260)º,B=(40-110)º and C=(200-260)º.
Background: This study was conducted to evaluate the hard palate bone density and thickness during 3rd and 4th decades and their relationships with body mass index (BMI) and compositions, to allow more accurate mini-implant placement. Materials and method: Computed tomographic (CT) images were obtained for 60 patients (30 males and 30 females) with age range 20-39 years. The hard palate bone density and thickness were measured at 20 sites at the intersection of five anterioposterior and four mediolateral reference lines with 6 and 3 mm intervals from incisive foramen and mid-palatal suture respectively. Diagnostic scale operates according to the bioelectric impedance analysis principle was used to measure body weight; percentages of body fa
... Show Morethe energy that a radiation source emits as light (photons), electromagnetic waves, or particles is known as radiation. X-ray is one type of ionizing radiation that falls within the electromagnetic wave category of short wavelengths. Because of their short wavelength. X-ray is a type of ionizing radiation that is used in a constantly growing number of diagnostic procedures. X-ray diagnostic imaging has been employed in the medical field for more than a century(Hariyoto et al., 2020). Radiation has advantages for human health, but there is also a risk. the impacts of Radiation on Fertility it is an oligospermia, or a reduction in the number of sperm cells, which is already possible after radiation exposure of 0.15 mGy. It Leads to impede
... Show MoreIn this paper, a study was made to determine the properties of Jovian radio bursts emitted at frequency 20.1MHZ. The data were provided from the Radio Jove archive for twelve years (2000-2012) for multi stations. The duration time for Long bursts (L) was (10-30) seconds and for Short bursts (S) was (10-20) seconds. The effect of radio bursts from the Sun and the galactic background were calculated at the same frequency and were found that radio bursts from the Sun will reduce the occurrence probability of Jovian radio bursts much more than radio bursts from the galactic background. The distribution of Jovian radio bursts was different; the occurrence probability with respect to the northern latitudes was more than the southern latitudes.
Teikyo Medical and medicine Journal (ISSN:03875547) is a monthly peer reviewed fast publishing international medical and medicine journal that aims to publish good quality of Medical and pharmaceutical, medicine and health science Journal.
Determining risk indicators for dental implants is an essential strategy for preventing peri-implant diseases and effective diagnosis of dental implant success. To investigate the impact of certain potential factors on the osseointegrated dental implant. Eighty-four individuals were included in our study, 50 cases as a patient’s group and 34 participants as a control group. All cases were diagnosed based on certain criteria, 30 (60%) of patients had peri-implantitis, 20 (40%) with severe periimplantitis, 36(72%) were generalized, and 15 (30%) as localized peri-implantitis cases. The study has indicated that 44.7% of dental implants were in the anterior maxilla, followed by (27.3%) posterior maxilla, (17.4%) posterior mandible, and (10.4%)
... Show MoreThe Evolution Of Information Technology And The Use Of Computer Systems Led To Increase Attention To The Use Of Modern Techniques In The Auditing Process , As It Will Overcome Some Of The Human Shortcomings In The Exercise Of Professional Judgment, Then It Can Improve The Efficiency And Effectiveness Of The Audit Process, Where The New Audit Methodologies Espouse The Concept Of Risk Which Includes Strategic Dimension With Regard To The Capacity Of The Entity To Achieve Its Goals, Which Requires Auditors To Rely On Advanced Technology That Can Identify The Factors Which Prevent The Entity From Achieving Its Objectives. The Idea Of Research Is To Preparing An Electronic Program Fer All Audit Work From Planning Through Sampling And Document
... Show MoreIn this paper, we investigate the basic characteristics of "magnetron sputtering plasma" using the target V2O5. The "magnetron sputtering plasma" is produced using "radio frequency (RF)" power supply and Argon gas. The intensity of the light emission from atoms and radicals in the plasma measured by using "optical emission spectrophotometer", and the appeared peaks in all patterns match the standard lines from NIST database and employed are to estimate the plasma parameters, of computes electron temperature and the electrons density. The characteristics of V2O5 sputtering plasma at multiple discharge provisos are studied at the "radio frequency" (RF) power ranging from 75 - 150 Wat
... Show MoreAbstract
Semiconductor-based gas sensors were prepared, that use n-type tin oxide (SnO2) and tin oxide: zinc oxide composite (SnO2)1-x(ZnO)x at different x ratios using pulse laser deposition at room temperature. The prepared thin films were examined to reach the optimum conditions for gas sensing applications, namely X-ray diffraction, Hall effect measurements, and direct current conductivity. It was found that the optimum crystallinity and maximum electron density, corresponding to the minimum charge carrier mobility, appeared at 10% ZnO ratio. This ratio appeared has the optimum NO2 gas sensitivity for 5% gas concentration at 300 °C working temperat
... Show MoreTin dioxide (SnO2) were mixed with (TiO2 and CuO) with concentration ratio (50, 60, 70, 80 and 90) wt% films deposited on single crystal Si and glass substrates at (523 K) by spray pyrolysis technique from aqueous solutions containing tin (II) dichloride Dihydrate (SnCl2, 2H2O), dehydrate copper chloride (CuCl2.2H2O) and Titanium(III) chloride (TiCl3) with molarities (0.2 M). The results of electrical properties and analysis of gas sensing properties of films are presented in this report. Hall measurement showed that films were n-type converted to p- type as titanium and copper oxide added at (50) % ratio. The D.C conductivity measurements referred that there are two mechanisms responsible about the conductivity, hence it possess two act
... Show More