A novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively. For plasma samples spiked at clinically relevant concentrations (5, 20, and 50 μg L-1), the sorbent showed good reusability over four cycles and negligible matrix effects. In comparison to previously published methods, the developed dispersive solid phase extraction method based on TA/Cu MOF performed better in terms of simplicity, enrichment factor, and analytical figures. Another objective of this study was to develop a liquid chromatography with tandem mass spectrometry technique that could be commonly and readily used for therapeutic drug monitoring of imatinib following extraction by solid phase extraction (SPE). Therapeutic monitoring applications can reliably quantify IMA in complex biological matrices as a result of the fast dispersive solid phase extraction (DSPE) procedure and environmentally friendly sorbent. For citation: Russol Abdul Salam Faraj, Noor H.K., Saba H. Jamel, Jasim Jamur M.S. LC-MS/MS method for the determination of imatinib mesylate in blood plasma samples after adsorption by copper tannic acid. ChemChemTech [Izv. Vyssh. Uchebn. Zaved. Khim. Khim. Tekhnol.]. 2025. V. 68. N 3. P. 27-35. DOI: 10.6060/ivkkt.20256803.7121.
In this work, a simple and very sensitive cloud point extraction (CPE) process was developed for the determination of trace amount of metoclopramide hydrochloride (MTH) in pharmaceutical dosage forms. The method is based on the extraction of the azo-dye results from the coupling reaction of diazotized MTH with p-coumaric acid (p-CA) using nonionic surfactant (Triton X114). The extracted azo-dye in the surfactant rich phase was dissolved in ethanol and detected spectrophotometrically at λmax 480 nm. The reaction was studied using both batch and CPE methods (with and without extraction) and a simple comparison between the two methods was performed. The conditions that may be affected by the extraction process and the sensitivity of m
... Show MoreA novel analytical method is developed for the determination of azithromycin. The method utilizes continuous flow injection analysis to enhance the chemiluminescence system of luminol, H2O2, and Cr(III). The method demonstrated a linear dynamic range of 0.001–100 mmol L-1 with a high correlation coefficient (r) of 0.9978, and 0.001–150 mmol L-1 with a correlation coefficient (r) of 0.9769 for the chemiluminescence emission versus azithromycin concentration. The limit of detection (L.O.D.) of the method was found to be 18.725 ng.50 µL−1 based on the stepwise dilution method for the lowest concentration within the linear dynamic range of the calibration graph. The relative standard deviation (R.S.D. %) for n = 6 was less than 1.2%
... Show More A simple, accurate and precise spectrophotometric method has been proposed for the determination of Mefenamic acid(MA) in dosage forms. Proposed method based on the reaction of cited drug with 1,2-Naphthoquinone-4-Sulfonic sodium (NQS). The optimum experimental condition have been studied. Beer's Law is obeyed in the concentration range 0.5-10.0 µg/mL at 450nm with detection limit of 0.189µg/mL. Effect of pH, reaction time, and volume of NQS on the determination of Mefenamic acid, have been examined. The proposed method has been successfully applied for the determination of Mefenamic acid in pharmaceutical preparations.
The objective of this study is to evaluate plasma levels of total Sialic acid TSA and Lipid –associated Sialic acid LSA as a marker of Rheumatoid Arthritis AR. Plasma Sialic acid is known as a parameter of inflammation. In the present study, in order to explore the potential role of sialic acid in arthritis rheumatoid, plasma sialic acid levels, plasma LSA and total protein in patients with arthritis rheumatoid were measured. A total 40 patients were compared with 40 healthy control subjects. Plasma TSA, LSA and TP level were determined spectrophotometrically in plasma samples. Plasma Sialic acid levels were significantly increased in RA (88.48±14.15 mg/dl, P<0.05) and LSA level were significantly increased in RA (26.3
... Show MoreA spectrophotometric- reverse flow injection analysis (rFIA) method has been proposed for the determination of Nitrazepam (NIT) in pure and pharmaceutical preparations. The method is based upon the coupling reaction of NIT with a new reagent O-Coumaric acid (OCA) in the presence of sodium periodate in an aqueous solution. The blue color product was measured at 632 nm. The variation (chemical and physical parameters) related with reverse flow system were estimated. The linearity was over the range 15 - 450 µg/mL of NIT with detection limits and limit of quantification of 3.425 and 11.417 µg mL-1 NIT,respectively. The sample throughput of 28 samples
... Show MoreAbstract: Background: High percentage of diabetes patients complain from post extraction hemorrhage. Many types of hemostatic materials are used to stop bleeding after teeth extraction: diode lasers are good hemostatic agents owing to their highly absorption by hemoglobin therefore they are used in soft tissue procedures with relatively no effects on dental hard tissues due to their poorly absorption by water and hydroxyapatite. Objectives: The aim of this study is to evaluate the efficiency of diode laser to assist the clot formation after tooth extraction for type II diabetes patients with minimum temperature elevation to prevent periodontal destruction. Materials and methods: From 12 type II diabetes patients (7 males and 5 females wi
... Show MoreIn this research velocity of moving airplane from its recorded digital sound is introduced. The data of sound file is sliced into several frames using overlapping partitions. Then the array of each frame is transformed from time domain to frequency domain using Fourier Transform (FT). To determine the characteristic frequency of the sound, a moving window mechanics is used, the size of that window is made linearly proportional with the value of the tracked frequency. This proportionality is due to the existing linear relationship between the frequency and its Doppler shift. An algorithm was introduced to select the characteristic frequencies, this algorithm allocates the frequencies which satisfy the Doppler relation, beside that the tra
... Show MoreThe objective of this work was to determine and compare the physiological changes in some: blood components (packed cell volume and hemoglobin) and plasma biochemical parameters (glucose, total protein, albumin, cholesterol and triglycerides) under 3 day of different types of stress: water deprivation, starvation, overcrowding and handling stress. Twenty five male Wister rats weighted 100-120 gm, were divided randomly into five groups: control, water deprivation, starvation, overcrowding and handling stress. On the third day of stress the animals anesthetized for blood collection; the results of blood component revealed a significant increase in PCV and a significant decrease in Hb of water deprivation group and starva
... Show MoreThe determination of captopril (CAP) using a new continuous flow injection analysis (CFIA) method was given in this work CAP in its pure state and some of its pharmaceutical preparations. The technique can be described as simple, fast, sensitive, easy to operate, and low-cost. The CAP reacted with ammonium ceric(IV) sulfate (ACS)2(NH4 )2SO4Ce(SO4)2. 3 H2O in an acidic medium and the reaction led to the formation of a white, slightly yellowish precipitate. The formed precipitate was studied using Ayah 6S×1-ST-2D Solar cell-CFI Analyzer, a through the reflection of accident light on the surfaces of the precipitate particles at (0-1800), expressed as the response
... Show More