Stereo Photogrammetry vs Computed Tomography for 3D Medical Measurements
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Craniofacial Surgery
Radiographic Assessment of Nasopalatine Canal Using Cone Beam Computed Tomography
...Show More Authors

View Publication
Scopus (8)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Al-khwarizmi Engineering Journal
A Review of the Stereo lithography 3D Printing Process and the Effect of Parameters on Quality
...Show More Authors

Stereo lithography (SLA) three-dimensional (3D) printing process is a type of additive manufacturing techniques that uses digital models from computer-aided design to automatically produce customized 3D objects. Around 30 years, it has been widely utilized in the manufacturing, design, engineering, industrial sectors and its applications in dentistry for manufacturing prosthodontics are very important. The stereo lithography technology is highly regarded because it can produce items with excellent precision especially when selecting the best process parameters. This review article offers a useful and scientific summary of SLA three-dimensional printing technology and its brief history. The specific type of 3D printers which is SLA type b

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Al-khwarizmi Engineering Journal
A Review of the Stereo lithography 3D Printing Process and the Effect of Parameters on Quality
...Show More Authors

Stereo lithography (SLA) three-dimensional (3D) printing process is a type of additive manufacturing techniques that uses digital models from computer-aided design to automatically produce customized 3D objects. Around 30 years, it has been widely utilized in the manufacturing, design, engineering, industrial sectors and its applications in dentistry for manufacturing prosthodontics are very important. The stereo lithography technology is highly regarded because it can produce items with excellent precision especially when selecting the best process parameters. This review article offers a useful and scientific summary of SLA three-dimensional printing technology and its brief history. The specific type of 3D printers which is SLA t

... Show More
Crossref (3)
Crossref
Publication Date
Wed May 01 2024
Journal Name
Journal Of Engineering
Orbital Prosthesis Rehabilitation in Biomedical Engineering by Means of Computer Vision-Photogrammetry and 3D Prototyping
...Show More Authors

Eye loss may be caused as a result of eye trauma, accidents, or malignant tumors, which leads the patient to undergo surgery to remove the damaged parts. This research examines the potential of computer vision represented by Structure from Motion (SfM) photogrammetry in fabricating the orbital prosthesis as a noninvasive and low-cost technique. A low-cost camera was used to collect the data towards extracting the dense 3D data of the patient facial features following Structure from Motion-Multi View Stereo (SfM-MVS) algorithms. To restore the defective orbital, a Reverse Engineering (RE) based approach has been applied using the similarity RE algorithms based on the opposite healthy eye to rehabilitate the defected orbital precisely

... Show More
View Publication
Crossref
Publication Date
Thu Oct 01 2015
Journal Name
Journal Of The Faculty Of Medicine Baghdad
The role of computed tomography in intra-axial posterior fossa tumors
...Show More Authors

Background: CT (computed tomography) is one of the first noninvasive imaging techniques in diagnosis of intra-axial posterior fossa tumors because it can accurately demonstrate, localize and characterize brain tumors, and can provide important information about the anatomic location, size, shape of the lesions and their mass effect on adjacent structures.
Objectives: To evaluate multi detectors CT characteristics of intra axial posterior fossa tumors and correlation of the CT characteristics of intra- axial posterior fossa tumors with the histopathological findings.
Patients & Methods: This is a cross sectional study including 26 patients with intra-axial posterior fossa tumors,15 males &11 females ,three cases were exclude

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Apr 01 2014
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Accuracy of ultrasound versus computed tomography in diagnosis of maxillary sinusitis
...Show More Authors

Background: ultrasound offers non-invasive, rapid and simple method for confirming the clinical diagnosis of maxillary sinus pathologies.
Objective: to evaluate the accuracy of real time ultrasound compared with the computed tomography in evaluation of maxillary sinusitis.
Patients and materials: This comparative cross-sectional study was done on 42 patients referred for computed tomography examination of paranasal sinuses in Al-Yarmook Teaching Hospital-Baghdad, from October 2012 to February 2013 with patients clinically suggesting an underlying maxillary sinusitis. Ultrasound and computed tomography examinations were carried out on the same day, the ultrasound being the first investigation. The sample of this study consisted of 2

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Postoperative assessment of dental implants by using multi-slice computed tomography
...Show More Authors

Background: Implantology is a fast growing area in dentistry. One of the most common issues encountered in dental implantation procedures is the lack of adequate preoperative planning. Conventional radiography may not be able to assess the true regional three-dimensional anatomical presentation. Multi Slice Computed Tomography provides data in 3-dimentional format offering information on craniofacial anatomy for diagnosis; this technology enables the virtual placement of implant in a 3-Dimensional model of the patient jaw (dental planning). Patients, Material and Methods: The sample consisted of (72) Iraqi patients indicated for dental implant (34 male and 38 female), age range between (20-70) years old. They were examined during a time p

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 01 2018
Journal Name
J Indian Soc Periodontol.
Osteoporosis effect on posterior mandible in preimplanted area for postmenopausal females using cone-beam computed tomography
...Show More Authors

Scopus (2)
Scopus
Publication Date
Sat Jan 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
A Micro Computed Tomography Assessment of New Carrier-Based Root Canal Fillings
...Show More Authors

Background: The main aim of the present study is to qualify and quantify voids formation of root canals obturated with GuttaCore (GC) and experimental Hydroxyapatite polyethylene (HA/PE) as new carrier-based root canal fillings by using micro computed tomography scan. Materials and methods: In the present study, eight straight single-rooted human permanent premolar teeth are selected and disinfected, then stored in distilled water. The teeth decoronated leaving a root length of 12mm each. The root canals instrumented by using crown down technique and the apical diameter of the root canal prepared to a size # 30/0.04 for achieving standardized measurements. A 5mL of 17% EDTA used to remove the smear layer followed by 5mL of 2.5% NaOCl and r

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 03 2011
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Performance of computed tomography in diagnosis and evaluation of traumatic intracerebral hemorrhage
...Show More Authors

Background: The intracerebral hemorrhage (ICH) can be classified as traumatic and spontaneous. The frontal and temporal lobes are classic sites for traumatic ICH, which are less commonly affected by spontaneous episodes. Computed tomography (CT) scanning is the most accurate radiological method for demonstrating the acute lesion of intracerebral hemorrhage (ICH). Both types are of high density, but traumatic bleeding is more frequently multifocal, in this study we are dealing with traumatic type of intracerebral hematoma. Aim of the study is to identify the accuracy and performance of CT scan in diagnosis and evaluation of intracerebral hemorrhage.
Patients and methods: 60 patients were examined, their ag

... Show More
View Publication Preview PDF
Crossref