Experimental and numerical study of the bulb's location effect on the behavior of under-reamed pile in expansive soil
...Show More Authors
Abstract<p>In this experimental and numerical analysis, three varieties of under-reamed piles comprising one bulb were used. The location of the bulb changes from pile to pile, as it is found at the bottom, center, and top of the pile, respectively. <italic>PLAXES 3D</italic> was used to conduct the research. In expansive soil, the under-reamed piles were 350 mm long, with the pile tip in dense sandy soil. The experiment was carried out in both saturated and unsaturated circumstances. The influence of the bulb location on the pile's bearing capacity for vertical and lateral loads, as well as the amount of swelling pressure and upward movement owing to swelling, was investigated. The results showed that in the unsaturated state, the bulb at the top of the pile gives bearing that is higher than the bulb at the bottom of the pile and near to the bulb in the center. In the case of unsaturated soil, the closer the bulb is to the top, the larger the bearing capacity, whereas in the event of swelling, the bearing capacity is highest when the bulb is in the middle of the pile. The same is true of the pile's upward movement, which is greater when the bulb is at the top than when it is at the bottom.</p>
Crossref
Publication Date
Sun Sep 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Study in to the Dynamic Behavior of Packed Distillation Column
...Show More Authors

The study of the dynamic behavior of packed distillation column was studied by frequency response analysis using Matlab program. A packed distillation column (80 mm diameter) (2000 mm height) filled with glass packing (Raschig Rings 10mm), packing height (1500 mm) has been modified for separation of methanol-water mixture (60 vol%). The column dynamic behavior was studied experimentally under different step changes in, feed rate (±30%), reflux rate (±22%), and reboiler heat duty (±150%), the top and bottom concentration of methanol were measured. A frequency response analysis for the above step response was carried out using Bode diagram, the log modulus and the phase angle were  used to analyze the process model. A Matlab progra

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Effect of Adding Sand on Clayey Soil Shear Strength
...Show More Authors
Abstract<p>The effect of adding sand on clayey soil shear strength is investigated in this study. Five different percentage of clay-sand mixtures are used; 100% clay with 0% sand termed 100C, 60% clay with 40% sand termed 60C-40S, 30% clay with 70% sand termed 30C-70S, 15% clay with 85% sand termed 15C-85S, and as well as 100% sand termed 100S. The used clay was obtained from Baghdad city in Iraq and classified as CH soil, while the used sand was taken from Al-Khider area from Iraq and classified as SW soil. The initial dry unit weight for all mixtures is 16 kN/m<sup>3</sup>. The results show that the variations of the soil shear strength properties with soil components content changes</p> ... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sat Jun 01 2019
Journal Name
Geoderma
Effect of cover crop management on soil hydraulic properties
...Show More Authors

View Publication
Scopus (77)
Crossref (77)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Advances In Civil Engineering
Behavior of Strengthened Composite Prestressed Concrete Girders under Static and Repeated Loading
...Show More Authors

The use of external posttensioning technique for strengthening reinforced concrete girders has been considerably studied by many researchers worldwide. However, no available data are seen regarding strengthening full-scale composite prestressed concrete girders with external posttensioned technique under static and repeated loading. In this research, four full-scale composite prestressed I-shape girders of 16 m span were fabricated and tested under static and repeated loading up to failure. Accordingly, two girders were externally strengthened with posttensioned strands, while the other two girders were left without strengthening. The experimental tests include deflection, cracking load, ultimate strength and strains at midspan, a

... Show More
View Publication
Scopus (18)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Iraqi Journal Of Physics
Numerical Simulation for Cylindrical Electrostatic Precipitator: Effect of the Applied Voltage
...Show More Authors

Coaxial (wire-cylinder) electrodes arrangements are widely used for electrostatic deposition of dust particles in flue gases, when a high voltage is applied to electrodes immersed in air and provide a strongly non-uniform electric field. The efficiency of electrostatic filters mainly depends on the value of the applied voltage and the distribution of the electric field. In this work, a two-dimensional computer simulation was constructed to study the effect of different applied voltages (20, 22, 25, 26, 28, 30 kV) on the inner electrode and their effect on the efficiency of the electrostatic precipitator. Finite Element Method (FEM) and COMSOL Multiphysics software were used to simulate the cross section of a wire cylinder. The results sh

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 29 2018
Journal Name
Journal Of Engineering
The Effect of Circular Perforation on a V-Corrugated Fin Performance under Natural Convection
...Show More Authors

An experimental investigation has been made to study the influence of using v-corrugated aluminum fin on heat transfer coefficient and heat dissipation in a heat sink. The geometry of fin is changed to investigate their performance. 27 circular perforations with 1 cm diameter were made. The holes designed into two ways, inline arrangement and staggered in the corrugated edges arrangement. The experiments were done in enclosure space under natural convection. Three different voltages supplied to the heat sink to study their effects on the fins performance. All the studied cases are compared with v-corrugated smooth solid fin. Each experiment was repeated two times to reduce the error and the data recorded after reaching t

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Fri May 21 2021
Journal Name
Transportation Infrastructure Geotechnology
Behavior of Floating Stone Columns and Development of Porewater Pressure Under Cyclic Loading
...Show More Authors

View Publication Preview PDF
Scopus (18)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
The Effect of Dry Farming and Water Stress under Subsurface Drip Irrigation System on Water and Rice Productivity
...Show More Authors
Abstract<p>A field experiment was carried out during the 2020 season at the College of Agricultural Engineering/ University of Baghdad, Al-Jadriya to evaluate the effect of dry farming when applying water stress under the subsurface drip irrigation system on water productivity and rice yield. The experiment was conducted with three levels of irrigation water stress when 10, 20 and 40% of the available water was depleted and in three dimensions between drip lines 10, 15 and 20 cm. The experiment was designed according to a randomized complete block design, according to the split plot design, with three replications. Determine the depth of irrigation water depending on the moisture depletion of th</p> ... Show More
View Publication
Scopus Crossref
Publication Date
Fri Jan 01 2016
Journal Name
International Journal Of Surgery Case Reports
Myositis ossificans: A rare location in the foot. Report of a case and review of literature
...Show More Authors

View Publication Preview PDF
Scopus (6)
Crossref (6)
Scopus Crossref
Publication Date
Sat Dec 02 2023
Journal Name
Journal Of Engineering
Simulation and Experimental Investigation of Performance and Flow Behavior for Steam Ejector Refrigeration System
...Show More Authors

The ejector refrigeration system is a desirable choice to reduce energy consumption. A Computational Fluid Dynamics CFD simulation using the ANSYS package was performed to investigate the flow inside the ejector and determine the performance of a small-scale steam ejector. The experimental results showed that at the nozzle throat diameter of 2.6 mm and the evaporator temperature of 10oC, increasing boiler temperature from 110oC to 140oC decreases the entrainment ratio by 66.25%. At the boiler temperature of 120oC, increasing the evaporator temperature from 7.5 to 15 oC increases the entrainment ratio by 65.57%. While at the boiler temperature of 120oC and

... Show More
View Publication Preview PDF