In Australia, most of the existing buildings were designed before the release of the Australian standard for earthquake actions in 2007. Therefore, many existing buildings in Australia lack adequate seismic design, and their seismic performance must be assessed. The recent earthquake that struck Mansfield, Victoria near Melbourne elevated the need to produce fragility curves for existing reinforced concrete (RC) buildings in Australia. Fragility curves are frequently utilized to assess buildings’ seismic performance and it is defined as the demand probability surpassing capacity at a given intensity level. Numerous factors can influence the results of the fragility assessment of RC buildings. Among the most important factors that can affect the performance-based seismic assessment of buildings are the building height and the characteristics of the earthquake. Despite this, very few studies accounted for the earthquake characteristics and the influence of height on the vulnerability of buildings in Australia. Consequently, the combined effect of building height and the characteristics of the earthquake were investigated in this study. This was achieved through numerical modeling and time-history analyses of three typical two-, four-, and nine-story RC frame buildings in Australia. Moreover, these buildings were subjected to three different types of ground motions which were: short- and long-duration, and near-fault earthquakes. Fragility analysis was then conducted for the three buildings under all the selected earthquake suites. It was noted from the median values of the fragility curves that the four-story and the nine-story RC buildings were 17% and 18% more susceptible to damage in comparison with the two-story building under short-duration earthquakes. Moreover, it was also noted that the median value of the vulnerability increased by 33%, 40%, and 50% for the two-, four-, and nine-story buildings, sequentially, when subjected to near-fault compared to short-duration earthquakes.
This research investigates manganese (Mn) extraction from Electric Arc Furnace Steel Slag (EAFS) by using the Liquid-liquid extraction (LLE) method. The chemical analysis was done on the slag using X-ray fluorescence, X-ray diffraction, and atomic absorption spectroscopy. This work consisted of two parts: the first was an extensive study of the effect of variables that can affect the leaching process rate for Mn element from slag (reaction time, nitric acid concentration, solid to liquid ratio, and stirring speed), and the second part evaluates the extraction of Mn element from leached solution. The results showed the possibility of leaching 83.5 % of Mn element from the slag at a temperature of 25°C, nitric acid co
... Show MoreGeneral Background: Breast cancer is the most prevalent cancer affecting women, with increasing incidence worldwide. Specific Background: Recent research has focused on the role of epigenetic changes in DNA damage, repair mechanisms, and the potential therapeutic effects of probiotics. Probiotics have shown promise in promoting tissue regeneration and DNA repair. Knowledge Gap: However, the precise impact of probiotics on DNA repair in cancer cells, specifically breast cancer cells, remains underexplored. Aims: This study aimed to evaluate the effects of probiotics on DNA damage repair in AMJ13 Iraqi breast cancer cells and assess the cytotoxic effects of probiotics on these cells. Results: Using the comet assay, we found significan
... Show MoreThe cathodic deposition of zinc from simulated chloride wastewater was used to characterize the mass transport properties of a flow-by fixed bed electrochemical reactor composed of vertical stack of stainless steel nets, operated in batch-recycle mode. The electrochemical reactor employed potential value in such a way that the zinc reduction occurred under mass transport control. This potential was determined by hydrodynamic voltammetry using a borate/chloride solution as supporting electrolyte on stainless steel rotating disc electrode. The results indicate that mass transfer coefficient (Km) increases with increasing of flow rate (Q) where .The electrochemical reactor proved to be efficient in removing zinc and was abl
... Show MoreIn this research, the dynamics process of charge transfer from the sensitized D35CPDT dye to tin(iv) oxide( ) or titanium dioxide ( ) semiconductors are carried out by using a quantum model for charge transfer. Different chemical solvents Pyridine, 2-Methoxyethanol. Ethanol, Acetonitrile, and Methanol have been used with both systems as polar media surrounded the systems. The rate for charge transfer from photo-excitation D35CPDTdye and injection into the conduction band of or semiconductors vary from a to for system and from a to for the system, depending on the charge transfer parameters strength coupling, free energy, potential of donor and acceptor in the system. The charge transfer rate in D35CPDT / the syst
... Show MoreThe partial level density PLD of pre-equilibrium reactions that are described by Ericson’s formula has been studied using different formulae of single particle level density . The parameter was used from the equidistant spacing model (ESM) model and the non- equidistant spacing model (non-ESM) and another formula of are derived from the relation between and level density parameter . The formulae used to derive are the Roher formula, Egidy formula, Yukawa formula, and Thomas –Fermi formula. The partial level density results that depend on from the Thomas-Fermi formula show a good agreement with the experimental data.
Heat exchanger is an important device in the industry for cooling or heating process. To increase the efficiency of heat exchanger, nanofluids are used to enhance the convective heat . transfer relative to the base fluid. - Al2O3/water nanofluid is used as cold stream in the shell and double concentric tube heat exchanger counter current to the hot stream basis oil. These nanoparticles were of particle size of 40 nm and it was mixed with a base fluid (water) at volume
concentrations of 0.002% and 0.004%. The results showed that each of Nusselt number and overall heat transfer coefficient increased as nanofluid concentrations increased. The pressure drop of nanofluid increased slightly than the base fluid because
As major nosocomial pathogens,
In this study, 20