Preferred Language
Articles
/
pRf7LZIBVTCNdQwC96fn
Poly-ether-ether-ketone (PEEK) versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 1. Stability, retainer failure, and participant satisfaction
...Show More Authors
Abstract<sec> <title>Background

Poly-ether-ether-ketone (PEEK) was introduced in dentistry as an alternative to metal alloys.

Objective

To assess the effectiveness of PEEK-fixed retainers in preserving the stability of mandibular anterior and participant satisfaction as compared to the Dead-soft coaxial fixed retainer (DSC).

Trial design

A single-centre, two-arm parallel groups randomized clinical trial.

Methods

The patients treated with pre-adjusted orthodontic appliances who have a Little’s Irregularity Index (LII) ≤ 0.5 mm have been enrolled in the trial. PEEK retainers were prepared to round 0.8 mm wire by computer-aided design and manufacturing, and the DSC wire was carefully adapted to the lingual surface of the lower anterior teeth. The primary outcome was the stability of lower anterior teeth as assessed by LII, while the secondary outcomes were changes in occlusal parameters, retainer failure, and patient satisfaction. The data were collected at the debonding stage (T0), 1 month (T1), 3 months (T3), and 6 months (T6) after starting the trial, except for patient’s satisfaction, which was recorded using an electronic form at T1 and T6.

Blinding

Single blinding of participants.

Results

A total of 46 participants with an age range of 12–28 years old were randomly allocated to the two groups (n = 23 in each). Only one participant dropped out; therefore, 45 participants were analysed. The DSC group showed a significant increase in LII at T3. Both retainer groups had comparable occlusal measurements, failure frequency, and survival time, with no significant difference. The patients in the DSC group reported a statistically significant perception of change in the position of their teeth compared to those in the PEEK group.

Harms

No harmful effects have been reported.

Limitations

Limited follow-up duration and the inability to blind the operator due to the nature of the intervention.

Conclusions

After 6-month retention, the PEEK retainer was equally effective to DSC retainers in maintaining the teeth alignment, with no significant differences regarding the failure frequency, survival rate, and general patient satisfaction.

Trial registration

https://register.clinicaltrials.gov. (NCT05557136).

Scopus Clarivate Crossref
View Publication
Publication Date
Thu Jun 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Molar tubes and failure rates–A review
...Show More Authors

Objectives: To review the failure rates of molar tubes and the effect of molar tube base design, adhesive type, and bonding technique on the failure rates of molar tubes. Data: The revolution of molar bonding greatly impacted fixed orthodontic appliance treatment by reducing chair-side time and improving patient comfort. Even with the many advantages of molar bonding, clinicians sometimes hesitate to use molar tubes due to their failure rates. Sources: Internet sources, such as Pubmed and Google Scholar. Study selection: studies testing the bond failure rate of molar tubes. Conclusions: The failure rate of the molar tubes can be reduced and the bond strength of the molar tubes can be improved by changing the design of the molar tube base

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Sat Dec 20 2025
Journal Name
Bmc Musculoskeletal Disorders
Effects of acute static stretching and dynamic warm-up protocols on shoulder function in young adult male athletes with shoulder impingement syndrome: a randomized controlled crossover trial
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Part-a-san-francisco-abstracts2019,acs
Part-A-San-Francisco-abstracts
...Show More Authors

Synthesis and study liquid crystalline properties of novel Benzimidazol-8-hydroxyquinoline complexes by reaction of a-Chloro acetic acid with 3,3'-dimethylbiphenyl-4,4'-diamine in 10% aqueous sodium hydroxide to synthesized compound [I] then the later compound reacted with o-phenylenediamine in 4N Hydrochloric acid to synthesized compound N4,N4'-bis((1H-benzo[d]imidazol-2-yl)methyl)-3,3'-dimethyl-[1,1'-biphenyl]-4,4'-diamine =[II] . While the complexes [III],[IV],[V],[VI] and [VII] synthesized from reacted compound [II] , 8-hydroxyquinoline with metal(II) salts { M= Mn(II), Fe(II), Ni (II), Cu(II),and Zn(II)}. Newly synthesized compounds were characterized using melting points, FT-IR, UV-Vis spectra, and some of them 1H NMR spectroscopy. ma

... Show More
Publication Date
Sat Jun 30 2012
Journal Name
Al-kindy College Medical Journal
The Necessity of Teaching Diabetic Patients the Correct way of Insulin Administration: A Clinical Trial to Improve Glycemic Control
...Show More Authors

Background: It is important to achieve good glycemic control to avoid long-term diabetic complications. It has been largely debated about the role of correct way of insulin administration to get the desired glycemic control.
Objective: To evaluate the effect of teaching diabetic patients who are on insulin therapy the correct way of injecting insulin and its effect on glycemic control.
Methods: A non randomized clinical trial with 820 diabetic patients on insulin therapy on whom A1 c estimation was performed before and after three months of teaching them the right injection technique.
Results : Sixty seven patients (8.17%) had A1 c 6.5% before they were enrolled in the study while the majority (753 patents, 91.82%) had A1 c 6.5%

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 30 2012
Journal Name
Al-kindy College Medical Journal
The Necessity of Teaching Diabetic Patients the Correct way of Insulin Administration: A Clinical Trial to Improve Glycemic Control
...Show More Authors

Background: It is important to achieve good glycemic control to avoid long-term diabetic complications. It has been largely debated about the role of correct way of insulin administration to get the desired glycemic control.
Objective: To evaluate the effect of teaching diabetic patients who are on insulin therapy the correct way of injecting insulin and its effect on glycemic control.
Methods: A non randomized clinical trial with 820 diabetic patients on insulin therapy on whom A1 c estimation was performed before and after three months of teaching them the right injection technique.
Results : Sixty seven patients (8.17%) had A1 c 6.5% before they were enrolled in the study while the majority (753 patents, 91.82%) had A1 c 6.5%

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 30 2023
Journal Name
Basrah Journal Of Surgery
Can Hyaluronic acid gel enhance wound healing faster than Advanced Platelets Rich Fibrin following surgical removal of impacted mandibular third molars? A Randomized Controlled Trial
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Sun Mar 01 2026
Journal Name
Journal Of The Society For Cardiovascular Angiography &amp; Interventions
A Novel Strategy to Promote Equity and Access in Interventional Cardiology: Early Insights From the 2024-2025 ACC Clinical Trial Research Cohort
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Wed Dec 15 2021
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Recipient Jaw and Implant Dimensions on Pre- and Post- Loading Dental Implant Stability: A Prospective Clinical Study
...Show More Authors

Background: Implant stability is a mandatory factor for dental implant (DI) osseointegration and long-term success. The aim of this study was to evaluate the effect of implant length, diameter, and recipient jaw on the pre- and post-functional loading stability. Materials and methods: This study included 17 healthy patients with an age range of 24-61 years. Twenty-two DI were inserted into healed extraction sockets to replace missing tooth/ teeth in premolar and molar regions in upper and lower jaws. Implant stability was measured for each implant and was recorded as implant stability quotient (ISQ) immediately (ISQ0), and at 8 (ISQ8) and 12 (ISQ12) weeks postoperatively, as well as post-functional loading (ISQPFL). The pattern of implant

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
American Journal Of Dermatology And Venereology
Intralesional Therapy of Vitiligo by 1% Lactic Acid Solution Versus Triamcinolone Acetonide Injection
...Show More Authors

KE Sharquie, AA Noaimi, S Adnan, AM Al-Niddawi, WK Aljanabi, American Journal of Dermatology and Venereology, 2020 - Cited by 2

View Publication
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
The Effect of MHD on a Longitudinal Flow of a Fractional Maxwell Fluid between Two Coaxial Cylinders
...Show More Authors

      In this paper fractional Maxwell fluid equation has been solved. The solution is in the Mettag-Leffler form. For  the corresponding solutions for ordinary Maxwell fluid are obtained as limiting case of general solutions. Finally, the effects of different parameters on the velocity and shear stress profile are analyzed through plotting the velocity and shear stress profile.

View Publication Preview PDF
Scopus Clarivate Crossref