Preferred Language
Articles
/
pRf7LZIBVTCNdQwC96fn
Poly-ether-ether-ketone (PEEK) versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 1. Stability, retainer failure, and participant satisfaction
...Show More Authors
Abstract<sec> <title>Background

Poly-ether-ether-ketone (PEEK) was introduced in dentistry as an alternative to metal alloys.

Objective

To assess the effectiveness of PEEK-fixed retainers in preserving the stability of mandibular anterior and participant satisfaction as compared to the Dead-soft coaxial fixed retainer (DSC).

Trial design

A single-centre, two-arm parallel groups randomized clinical trial.

Methods

The patients treated with pre-adjusted orthodontic appliances who have a Little’s Irregularity Index (LII) ≤ 0.5 mm have been enrolled in the trial. PEEK retainers were prepared to round 0.8 mm wire by computer-aided design and manufacturing, and the DSC wire was carefully adapted to the lingual surface of the lower anterior teeth. The primary outcome was the stability of lower anterior teeth as assessed by LII, while the secondary outcomes were changes in occlusal parameters, retainer failure, and patient satisfaction. The data were collected at the debonding stage (T0), 1 month (T1), 3 months (T3), and 6 months (T6) after starting the trial, except for patient’s satisfaction, which was recorded using an electronic form at T1 and T6.

Blinding

Single blinding of participants.

Results

A total of 46 participants with an age range of 12–28 years old were randomly allocated to the two groups (n = 23 in each). Only one participant dropped out; therefore, 45 participants were analysed. The DSC group showed a significant increase in LII at T3. Both retainer groups had comparable occlusal measurements, failure frequency, and survival time, with no significant difference. The patients in the DSC group reported a statistically significant perception of change in the position of their teeth compared to those in the PEEK group.

Harms

No harmful effects have been reported.

Limitations

Limited follow-up duration and the inability to blind the operator due to the nature of the intervention.

Conclusions

After 6-month retention, the PEEK retainer was equally effective to DSC retainers in maintaining the teeth alignment, with no significant differences regarding the failure frequency, survival rate, and general patient satisfaction.

Trial registration

https://register.clinicaltrials.gov. (NCT05557136).

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Jan 01 2017
Journal Name
Al-mustansiriyah
Synthesis, Spectroscopic and Biological Studies of a New Some Complexes with N-Pyridin-2-Ylmethyl-Benzene-1, 2Diamine
...Show More Authors

Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Population Therapeutics And Clinical Pharmacology
Evaluation of the Expression of RCC and KIM-1 Biomarkers in Nephrotoxicity of Rabbits Treated with Ochratoxins A
...Show More Authors

View Publication
Crossref (1)
Clarivate Crossref
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Separation and determination of poly aromatic hydrocarbons in vegetables samples in Baghdad city using HPLC Technique
...Show More Authors

The Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -

... Show More
Publication Date
Sun Jun 04 2017
Journal Name
Baghdad Science Journal
Effect of Ferocene Concentration on the Percent Conversion and Molecular Weight of Poly(Methyl Methacrylate) Homopolymers
...Show More Authors

This research is addressing the effect of different ferrocene concentration (0.00, 2.15x10-3, 4.30x10-3, 8.60x10-3, and 12.9x10-3) on the bulk free radical polymerization of methyl methacrylate monomer in benzene using benzoyl peroxide as initiator. The polymerization was conducted at 60º C under free oxygen atmosphere. The resulting polymers were characterized by FTIR. The results were compared with the presence and absence of ferrocene at 10% conversion. The %conversion was 3.04% with no ferrocene present in the polymerization medium and its increase to 9.06 with a first lowest ferrocene concentration added, i.e. 2.15 x10-3mol/l. This was positively reflected on the poly(methyl methacrylate) molecular weight measured by viscosity techniq

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Nov 13 2014
Journal Name
Asian Academic Research Associates
Thermodynamic Study of Poly (Vinyl Alcohol) in Aqueous Solution and in Tetrahydrofurfuryl alcohol at Different Temperatures
...Show More Authors

Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Synthesis of Novel N-Substituted Dimethylmaleimidyl Esters and Their Applications as Plasticizers for Poly(Vinyl Chloride)
...Show More Authors

Three N-(hydroxylphenyl) dimethylmaleimides were directly prepared in good yields (81-86)% from the reaction of dimethylmaleic anhydride with amino phenols. The prepared imides were esterified to the corresponding benzoates, methacrylates and cinnamates via their reaction with different acid chlorides in the presence of triethylamine. The prepared esters were tested as plasticizers for PVC via preparing of thirty six samples of PVC with the prepared esters in certain weight ratio followed by recording their softening points. Comparison the results with the universal plasticizers for PVC (DOP) and (DBP) indicated that the prepared esters in general have high plasticizing efficiency.

View Publication Preview PDF
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Excision of Soft Tissue Oral Lesions by 810 nm Diode Laser
...Show More Authors

The present study was conducted on 20 patients suffering from different types of lesion like
pyogenic granuloma, peripheral giant cell granuloma, mucoceles, pregnancy tumour, Fordyce's granules
and irritating fibroma.The cases were selected from outpatient clinic of the Al Kydhemya Teaching
Hospital. Patients were treated by diode laser (810±20 nm) at the affected areas of the oral cavity with
continuous contact focused mode until excision of the lesion with coagulation of the oozing area after
excision. Patients were followed up after 2 days, 7 days and 2 weeks to assess healing process and any
post operative complication. Some of undiagnosed lesion sent for histopathological examination. No
serious complications w

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 13 2017
Journal Name
Al-khwarizmi Engineering Journal
Improving Shear Strength of Soft Clay by Using Torn Belts Chips
...Show More Authors

Random throwing of industrial waste has a significant impact on the environment unless it takes into account the conditions of engineered destroying and/or re-used. Taking the advantage of re-using waste materials in engineering projects represents a well-planned project in order to resolve a lot of engineering problems for some difficult soils. The objective of this study was to evaluate the capability and effects of Rubber Shreds (RS) from scrap torn belts towards improving the shear strength of soft clay. A direct shear tests were conducted on soft clay-RS mixture. The following parameters were investigated to study the influence of RS content, water content, normal stress, and dilation ratio. From experimental test results it was fou

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 05 2017
Journal Name
Neural Computing And Applications
Hybrid soft computing approach for determining water quality indicator: Euphrates River
...Show More Authors

View Publication
Scopus (38)
Crossref (33)
Scopus Clarivate Crossref
Publication Date
Sat Sep 01 2018
Journal Name
2018 11th International Conference On Developments In Esystems Engineering (dese)
Natural Rivers Longitudinal Dispersion Coefficient Simulation Using Hybrid Soft Computing Model
...Show More Authors

View Publication
Scopus (22)
Crossref (10)
Scopus Clarivate Crossref