Preferred Language
Articles
/
pRf7LZIBVTCNdQwC96fn
Poly-ether-ether-ketone (PEEK) versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 1. Stability, retainer failure, and participant satisfaction
...Show More Authors
Abstract<sec> <title>Background

Poly-ether-ether-ketone (PEEK) was introduced in dentistry as an alternative to metal alloys.

Objective

To assess the effectiveness of PEEK-fixed retainers in preserving the stability of mandibular anterior and participant satisfaction as compared to the Dead-soft coaxial fixed retainer (DSC).

Trial design

A single-centre, two-arm parallel groups randomized clinical trial.

Methods

The patients treated with pre-adjusted orthodontic appliances who have a Little’s Irregularity Index (LII) ≤ 0.5 mm have been enrolled in the trial. PEEK retainers were prepared to round 0.8 mm wire by computer-aided design and manufacturing, and the DSC wire was carefully adapted to the lingual surface of the lower anterior teeth. The primary outcome was the stability of lower anterior teeth as assessed by LII, while the secondary outcomes were changes in occlusal parameters, retainer failure, and patient satisfaction. The data were collected at the debonding stage (T0), 1 month (T1), 3 months (T3), and 6 months (T6) after starting the trial, except for patient’s satisfaction, which was recorded using an electronic form at T1 and T6.

Blinding

Single blinding of participants.

Results

A total of 46 participants with an age range of 12–28 years old were randomly allocated to the two groups (n = 23 in each). Only one participant dropped out; therefore, 45 participants were analysed. The DSC group showed a significant increase in LII at T3. Both retainer groups had comparable occlusal measurements, failure frequency, and survival time, with no significant difference. The patients in the DSC group reported a statistically significant perception of change in the position of their teeth compared to those in the PEEK group.

Harms

No harmful effects have been reported.

Limitations

Limited follow-up duration and the inability to blind the operator due to the nature of the intervention.

Conclusions

After 6-month retention, the PEEK retainer was equally effective to DSC retainers in maintaining the teeth alignment, with no significant differences regarding the failure frequency, survival rate, and general patient satisfaction.

Trial registration

https://register.clinicaltrials.gov. (NCT05557136).

Scopus Clarivate Crossref
View Publication
Publication Date
Thu Jan 01 2015
Journal Name
International Journal Of Optics And Applications
Modeling and Analysis of a Miniaturized Ring Modulator Using Silicon-Polymer-Metal Hybrid Plasmonic Phase Shifter. Part I: Theoretical Framework
...Show More Authors

This paper presents comprehensive analysis and investigation for 1550nm and 1310nm ring optical modulators employing an electro-optic polymer infiltrated silicon-plasmonic hybrid phase shifter. The paper falls into two parts which introduce a theoretical modeling framework and performance assessment of these advanced modulators, respectively. In this part, analytical expressions are derived to characterize the coupling effect in the hybrid phase shifter, transmission function of the modulator, and modulator performance parameters. The results can be used as a guideline to design compact and wideband optical modulators using plasmonic technology

View Publication
Publication Date
Mon Aug 01 2016
Journal Name
2016 3rd International Conference On Computer And Information Sciences (iccoins)
Measurement model of e-SQ dimensions and users' satisfaction in Malaysia IHL
...Show More Authors

View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sat Nov 10 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Satisfaction of Patients, Coronary Arteries in Related to Nursing and Medical Care
...Show More Authors

Objectives of the study: The study aims to assess satisfy of the coronary artery patients for the care product from
the nurse and physician and to find out the relationship between patient satisfaction with the social and the
clinical characteristics of the patients.
Methodology: A descriptive design study conducted using the evaluation approach for the duration of June 3
rd
2012 to January 31, 2013. Non-probability sample of (60) patients who were visiting or admitted (inpatient or
outpatient) to the teaching hospital in Baquba with the diagnosis of coronary artery disease. A questionnaire have
been built and develop by the researcher based on review of literature and previous research, the form included of
(3) p

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Dental Hypotheses
Assessment of the Impact of Adhesive and Wires Types on the Tensile Bond Strength of Fixed Lingual Retainers Used in Orthodontics: An In Vitro Study
...Show More Authors

Introduction: We aimed to assess the impact of adhesive and wires types on the tensile bond strength of fixed lingual retainers. Methods: A total of 160 intact bovine teeth were collected, cleaned, stored in 25% sodium hypochlorite, and randomly assigned to two groups based on the adhesive type: a two-step adhesive and a one-step adhesive. Each group was further divided into four subgroups based on the type of lingual retainer wire, which included (A) 8-strand braided stainless steel wire, (B) three-strand titanium retainer wire, (C) stainless steel chain, and (D) fiber-reinforced retainer. A tensile bond strength test was conducted using a universal testing machine at a controlled speed of 10 mm/min. Result: The 8-strand braided stainles

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Wed Aug 28 2024
Journal Name
World Academy Of Sciences Journal
Serum angiopoietin‑1 as a biomarker of missed miscarriage
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
The Turkish Journal Of Endocrinology And Metabolism
Cell-free DNA as a Clinical Indicator in Maternal Blood
...Show More Authors

As many expensive and invasive procedures are used for the diagnosis or follow-up of clinical conditions, the measurement of cell-free DNA is a promising, noninvasive method, which considers using blood, follicular fluid, or seminal fluid. This method is used to determine chromosomal abnormalities, genetic disorders, and indicators of some diseases such as polycystic ovary syndrome, pre-eclampsia, and some malignancies. Cell-free DNA, which are DNA fragments outside the nucleus, originates from an apoptotic process. However, to be used as a marker for the previously mentioned diseases is still under investigation. We discuss some aspects of using cell-free DNA measurements as an indicator or marker for pathological conditions.

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Jan 01 2015
Journal Name
The International Journal Of Biotechnology,
LACTIC ACID AS SPACER BETWEEN POLY ACRYLIC ACID AND 4- AMINOANTIPYRINE
...Show More Authors

Preview PDF
Publication Date
Sat Jul 02 2016
Journal Name
Bioremediation Journal
Kinetic, thermodynamic, and equilibrium biosorption of Pb(II), Cu(II), and Ni(II) using dead mushroom biomass under batch experiment
...Show More Authors

In this study, a low-cost biosorbent, dead mushroom biomass (DMB) granules, was used for investigating the optimum conditions of Pb(II), Cu(II), and Ni(II) biosorption from aqueous solutions. Various physicochemical parameters, such as initial metal ion concentration, equilibrium time, pH value, agitation speed, particles diameter, and adsorbent dosage, were studied. Five mathematical models describing the biosorption equilibrium and isotherm constants were tested to find the maximum uptake capacities: Langmuir, Freundlich, Redlich-Peterson, Sips, and Khan models. The best fit to the Pb(II) and Ni(II) biosorption results was obtained by Langmuir model with maximum uptake capacities of 44.67 and 29.17 mg/g for these two ions, respectively, w

... Show More
Crossref (5)
Crossref
Publication Date
Thu Dec 30 2021
Journal Name
Iraqi Journal Of Science
Modelling the Role of the Inner Electrode Radius on the Oxygen Negative Corona Discharge in Coaxial Electrode Geometry
...Show More Authors

The charge species plays a vital role in changing the field in direct current discharge (DC). This article introduces a numerical modeling in one dimension of the inner electrode diameter of oxygen-fed negative corona discharge in coaxial electrodes geometry. The properties of negative corona plasma in a concentric cylindrical electrodes (wire-cylinder) were simulated by COMSOL Multiphysics software. Various diameters of negative corona electrode, namely 0.01, 0.025, 0.05, 0.075, and 0.125 mm, were applied, ​​where the diameter of the outer cylindrical electrode was taken as 15 mm. The model was run at atmospheric pressure and the applied negative voltage was
-10 KV. Moreover, oxygen gas was used to fill the inter-electrodes dist

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Desalination And Water Treatment
A novel forward osmosis for treatment of high-salinity East Baghdad oilfield produced water as a part of a zero liquid discharge system
...Show More Authors

This study investigated a novel application of forward osmosis (FO) for oilfield produced water treatment from the East Baghdad oilfield affiliated to the Midland Oil Company (Iraq). FO is a part of a zero liquid discharge system that consists of oil skimming, coagulation/flocculation, forward osmosis, and crystallization. Treatment of oilfield produced water requires systems that use a sustainable driving force to treat high-ionic-strength wastewater and have the ability to separate a wide range of contaminants. The laboratory-scale system was used to evaluate the performance of a cellulose triacetate hollow fiber CTA-HF membrane for the FO process. In this work, sodium chloride solution was used as a feed solution (FS) with a concentratio

... Show More
View Publication Preview PDF