Preferred Language
Articles
/
pRf6UZEBVTCNdQwCopTV
IoT E-health System for Cardiac Telemonitoring
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Antiplatelts Activity of Vitamin E in Relation to Dose and Duration of Therapy
...Show More Authors

           Vitamin E, having the well known antioxidant activity  through scavenging free radicals Ùˆ it occurs in several  isomeric forms , these isomers have relatively different functions . One of these actions is related to its ability to inhibit platelets aggregation and hence thrombosis. The present study included a total number of apparently healthy  62 males . 11of them served as standard group , treated  with 100 mg aspirin /day for more than one month . Another 31 subjects were randomly grouped into 5 groups that received different daily doses of α – tocopherol : 400 IU , 800 IU and 1200 IU for  2-6 months.The remainder ( 20 ) subjects served

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 06 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn: 1683 - 3597 , E-issn : 2521 - 3512)
Effects of Vitamin E and Q10 Supplementation against Doxorubicin-Induced Neurotoxicity in Rats
...Show More Authors

Doxorubicin (DOX) is a chemotherapeutic agent; it is widely used in human malignancies. Its long-term use can cause neurobiological side-effects. Vitamin E and Coenzyme Q10may possess neuroprotective effects. This work was designed to investigate the effect of vitamin E and the coenzyme Q10(CoQ10) supplementation on neurotoxicity induced by doxorubicin(DOX) in rats. Forty nine adult rats of both sexes were used in this study; the animals were randomly enrolled into seven groups of 7 rats each. Group I: negative control (rats administered corn oil); Group II: Vitamin E at a dose of 100mg/kg/d for 3 weeks ; Group III: CoQ10 at a dose of 50 mg/kg/d for 3 weeks; Group IV: positive control (Doxorubicin 2

... Show More
View Publication
Scopus (9)
Crossref (5)
Scopus Crossref
Publication Date
Thu Feb 01 2018
Journal Name
Journal Of Computational And Theoretical Nanoscience
Development of Wireless Controlling and Monitoring System for Robotic Hand Using Zigbee Protocol
...Show More Authors

Nowadays, the robotic arm is fast becoming the most popular robotic form used in the industry among others. Therefore, the issues regarding remote monitoring and controlling system are very important, which measures different environmental parameters at a distance away from the room and sets various condition for a desired environment through a wireless communication system operated from a central room. Thus, it is crucial to create a programming system which can control the movement of each part of the industrial robot in order to ensure it functions properly. EDARM ED-7100 is one of the simplest models of the robotic arm, which has a manual controller to control the movement of the robotic arm. In order to improve this control s

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Engineering
Design of a PID-Lead Compensator for a Twin Rotor Aerodynamic System (TRAS)
...Show More Authors

This paper deals with a Twin Rotor Aerodynamic System (TRAS). It is a Multi-Input Multi-Output (MIMO) system with high crosscoupling between its two channels. It proposes a hybrid design procedure that combines frequency response and root locus approaches. The proposed controller is designated as PID-Lead Compensator (PIDLC); the PID controller was designed in previous work using frequency response design specifications, while the lead compensator is proposed in this paper and is designed using the root locus method. A general explicit formula for angle computations in any of the four quadrants is also given. The lead compensator is designed by shifting the dominant closed-loop poles slightly to the left in the s-plane. This has the effect

... Show More
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
MEASURING OF FARMERS ADOPTION LEVEL FOR MODERN IRRIGATION SYSTEM AND THEIR WIDE APPLICATION
...Show More Authors

74 fanners were randomily selected from the Lc:ital. of 406 fanners using the Modern Irrigation System up to November , 2000 , for the purpose of wide adoptation of such system. Rcsults indicated according to the data which has been obtained and statistically analysed by the statistical package for the Social Sciences (SPSS) program showed that the majority of the farmers adopted this new system of irrigation due to the increase in the yield up to 5" .

View Publication Preview PDF
Publication Date
Fri Jul 17 2026
Journal Name
Journal Of Physical Education
Analytical Study of Goalkeeper Positioning Using MH System for Free Kick in Soccer
...Show More Authors

View Publication
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Using TermoDeck System for Pre-Cooling/ Heating to Control the Building Inside Conditions
...Show More Authors

In this paper, experimental study has been done for temperature distribution in space conditioned with Ventilation Hollow Core Slab (TermoDeck) system. The experiments were carried out on a model room with dimensions of (1m 1.2m 1m) that was built according to a suitable scale factor of (1/4). The temperature distributions was measured by 59 thermocouples fixed in several locations in the test room. Two cases were considered in this work,  the first one during unoccupied period at night time (without external load) and the other at day period with external load of 800W/m2 according to solar heat gain calculations during summer season in Iraq. All results confirm the use of TermoDeck system for ventilation and cooling/heat

... Show More
View Publication Preview PDF
Publication Date
Wed May 31 2017
Journal Name
Journal Of Engineering
Design and Implementation of Classical Sliding Mode Controller for Ball and Plate System
...Show More Authors

Ball and Plate (B&P) system is a benchmark system in the control engineering field that has been used to verify many control methods. In this paper the design of a sliding mode . controller has been investigated and verified in real-time via implementation on a real ball and plate system hardware. The mathematical model has been derived and the necessary parameters have been measured. The sliding mode controller has been designed based on the obtained mathematical model. The resulting controller has been implemented using the Arduino Mega 2560 and a ball and plate system built completely from scratch. The Arduino has been programmed by the Arduino support target for Simulink. Three test signals has been used for verification purposes

... Show More
View Publication Preview PDF
Publication Date
Fri May 01 2020
Journal Name
Journal Of Physics: Conference Series
Recent modification of Homotopy perturbation method for solving system of third order PDEs
...Show More Authors

This paper presents new modification of HPM to solve system of 3 rd order PDEs with initial condition, for finding suitable accurate solutions in a wider domain.

Scopus (19)
Scopus
Publication Date
Tue Dec 01 2020
Journal Name
International Journal Of Electrical And Computer Engineering (ijece)
A Haptic feedback system based on leap motion controller for prosthetic hand application
...Show More Authors

Leap Motion Controller (LMC) is a gesture sensor consists of three infrared light emitters and two infrared stereo cameras as tracking sensors. LMC translates hand movements into graphical data that are used in a variety of applications such as virtual/augmented reality and object movements control. In this work, we intend to control the movements of a prosthetic hand via (LMC) in which fingers are flexed or extended in response to hand movements. This will be carried out by passing in the data from the Leap Motion to a processing unit that processes the raw data by an open-source package (Processing i3) in order to control five servo motors using a micro-controller board. In addition, haptic setup is proposed using force sensors (F

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Crossref