Preferred Language
Articles
/
pBdtX5MBVTCNdQwCxtLB
Multicomponent Equilibrium Isotherms and Kinetics Study of Heavy Metals Removal from Aqueous Solutions Using Electrocoagulation Combined with Mordenite Zeolite and Ultrasonication

Combining different treatment strategies successively or simultaneously has become recommended to achieve high purification standards for the treated discharged water. The current work focused on combining electrocoagulation, ion-exchange, and ultrasonication treatment approaches for the simultaneous removal of copper, nickel, and zinc ions from water. The removal of the three studied ions was significantly enhanced by increasing the power density (4–10 mA/cm2) and NaCl salt concentration (0.5–1.5 g/L) at a natural solution pH. The simultaneous removal of these metal ions at 4 mA/cm2 and 1 g NaCl/L was highly improved by introducing 1 g/L of mordenite zeolite as an ion-exchanger. A remarkable removal of heavy metals was reported, as the initial concentration of each metal decreased from approximately 50 ppm to 1.19 for nickel, 3.06 for zinc, and less than 1 ppm for copper. In contrast, ultrasonication did not show any improvement in the treatment process. The extended Langmuir isotherm model convincingly described the experimental data; the Temkin and Dubinin-Radushkevich isotherm models have proven that the removal processes were physical and exothermic. Finally, the pseudo-second-order kinetics model appropriately explained the kinetics of the process with correlation coefficients of 0.9337 and 0.9016, respectively.

Crossref
View Publication
Publication Date
Tue Dec 26 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
A Comparative Study of Blood Levels of Manganese, Some Macroelements and Heavy Metals in Obese and Non-Obese Polycystic Ovary Syndrome Patients

Polycystic ovary syndrome (PCOS) is a prevalent condition in women of reproductive age. It is characterized by androgen excess and chronic anovulation. Some trace elements, macroelements, and heavy metals have been linked to pathophysiological mechanisms of PCOS .

To study the alterations in the serum levels of the trace element manganese (Mn), some macroelements, magnesium(Mg) and calcium (Ca), and the heavy metals cadmium (Cd) and lead (Pb), in obese and non-obese PCOS patients; and the association of these alterations with some of the hormonal changes occurring in PCOS.

The study was carried out at Kamal Al-Samarrai Hospital (Center for Infertility treatment and in vitro Fertilization "IVF") Baghdad- Iraq. Eig

... Show More
Crossref (3)
Crossref
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
Role of high sensitivity C - Reactive protein and some of heavy metals in patients with rheumatoid arthritis

Scopus (3)
Crossref (2)
Scopus Crossref
View Publication
Publication Date
Sat Jul 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
Predicting of heavy metals in some areas of Iraq using spectral analysis techniques
Abstract<p>Soil that has been contaminated by heavy metals is a serious environmental problem. A different approach for forecasting a variety of soil physical parameters is reflected spectroscopy is a low-cost, quick, and repeatable analytical method. The objectives of this paper are to predict heavy metal (Ti, Cr, Sr, Fe, Zn, Cu and Pb) soil contamination in central and southern Iraq using spectroscopy data. An XRF was used to quantify the levels of heavy metals in a total of 53 soil samples from Baghdad and ThiQar, and a spectrogram was used to examine how well spectral data might predict the presence of heavy metals metals. The partial least squares regression PLSR models performed well in pr</p> ... Show More
Scopus (1)
Crossref (1)
Scopus Crossref
View Publication
Publication Date
Thu Apr 18 2019
Journal Name
Iraqi Journal Of Science
Simple Colorimetric Method Using Aqueous Solution to Detect Heavy Metal

Simple method has been used to determine the absence of heavy metals in an aqueous solution. Fluorescein was used as the base colorimetric materialThis was doped with CuCl2 and the final solution showeda clear change in color. This change was correlated with the change in both pH and electrical conductivity of the solution. The optical property as an obvious change of the spectra was observed. Therefore, this simple method could be proposed as a method to detectheavy metals in any solution.

View Publication Preview PDF
Publication Date
Mon Apr 17 2017
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
INVESTIGATION THE CONTENT OF SOME HEAVY METALS IN COLORED PLASTIC TABLE DISHES.: INVESTIGATION THE CONTENT OF SOME HEAVY METALS IN COLORED PLASTIC TABLE DISHES.

The aim of this study is to investigate the existence of some heavy metals (lead, cadmium, chromium) in colored plastic table dishes and study the migration of these metals to the food meals and the affecting factors in migration , such as storage period and food temperature. Six kinds of colored plastic table dishes were collected from Baghdad markets. The heavy metals in table dishes and in the prepared food meals put in them were estimated using atomic absorption spectrophotometer (Shimadzu A5000). The results indicated the existence of lead in all samples (1.61_1.00 mg/ kg) and chromium in three samples (0.85_0.97 mg/ kg) while other samples are free of chromium, and cadmium. Investigating the migration of these metals to food at dif

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 30 2020
Journal Name
International Journal Of Civil Engineering
Adsorption of Meropenem Antibiotics from Aqueous Solutions on Multi-Walled Carbon Nanotube

Pharmaceutical-instigated pollution is a major concern, especially in relation to aquatic environments and drugs such as meropenem antibiotics. Adsorbents, such as multi-walled carbon nanotubes, offer potential as means of removing polluting meropenem antibiotics and other similar compounds from water. In order to evaluate the effectiveness of multi-walled carbon nanotubes in this capacity, various experimental parameters, including contact time, initial concentration, pH, temperature and the dose of adsorbent have been investigated. The Langmuir and the Freundlich isotherm models have been used. The data obtained using a modified Langmuir model have been consistent with the experimental ones; the best pH value has been obtained to have the

... Show More
Crossref (3)
Crossref
Publication Date
Mon Nov 01 2021
Journal Name
Journal Of Ecological Engineering
Adsorption of Lead Ions from Aqueous Solutions onto Rice Husks, Continuous System

Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
View Publication
Publication Date
Wed Apr 01 2020
Journal Name
Plant Archives
Determination of heavy metals in tattoo inks from the local market in Baghdad city

Scopus (2)
Scopus
Publication Date
Thu Dec 01 2016
Journal Name
Journal Of Hazardous Materials
Hierarchical porous structured zeolite composite for removal of ionic contaminants from waste streams and effective encapsulation of hazardous waste

Scopus (52)
Crossref (46)
Scopus Clarivate Crossref
View Publication
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Manganese Ions (Mn2+) from a Simulated Wastewater by Electrocoagulation/ Electroflotation Technologies with Stainless Steel Mesh Electrodes: Process Optimization Based on Taguchi Approach

This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis

... Show More
Crossref (5)
Crossref
View Publication Preview PDF