The Multiple Signal Classification (MUSIC) algorithm is the most popular algorithm to estimate the Angle of Arrival (AOA) of the received signals. The analysis of this algorithm (MUSIC) with typical array antenna element ( ) shows that there are two false direction indication in the plan
aligned with the axis of the array. In this paper a suggested modification on array system is proposed by using two perpendiculars crossed dipole array antenna in spite of one array antenna. The suggested modification does not affect the AOA estimation algorithm. The simulation and results shows that the proposed solution overcomes the MUSIC problem without any effect on the performance of the system.
The goal beyond this Research is to review methods that used to estimate Logistic distribution parameters. An exact estimators method which is the Moment method, compared with other approximate estimators obtained essentially from White approach such as: OLS, Ridge, and Adjusted Ridge as a suggested one to be applied with this distribution. The Results of all those methods are based on Simulation experiment, with different models and variety of sample sizes. The comparison had been made with respect to two criteria: Mean Square Error (MSE) and Mean Absolute Percentage Error (MAPE).
Mass transfer was examined at a stationary rectangular copper electrode (cathode) by using the reduction of cupric ions as the electrochemical reaction. The influence of electrolyte temperature (25, 45, and 65 oC), and cupric ions concentration (4, 8, and 12 mM) on mass transfer coefficient were investigated by using limiting current technique. The mass transfer coefficient and hence the Sherwood number was correlated as Sh =
The present work involved four steps: First step include reaction of acrylamide ,N-?-Methylen-bis(acryl amide) and N-tert Butyl acryl amide with poly acryloyl chloride in the presence of triethyl amine (Et3N) as catalyst, the second step include homopolymerization of all products of the first step by using benzoyl peroxide(BPO) as initiator in (80-90)Co in the presence of Nitrogen gas(N2). In the third step the poly acrylimide which prepare in second step was convert into potassium salt by using alcoholic potassium hydroxide solution. Fourth step include Alkylation of the prepared polymeric salts in third step by react it with different alkyl halides(benzyl chloride, allylbromide , methyl iodide) by using DMF as solvent for(10-12) hours.
... Show MoreHigh performance liquid chromatography was applied for the separation and identification of four antharquinone derivatives, aloe emodin, emodin, chrysophanol and physcion. The separation was carried out using Eurospher 100, C18 column (4.6 mm i.d. x 250 mm, 5 µm) under the following conditions: acetonitile (solvent A) and water: acetic acid (99.9: 0.1 v/v, pH 3.5)( solvent B) as a mobile phase with isocratic elution with 30% solvent B at flow rate 0.8 ml/min. The detection wavelength was set at 254 nm. The four antharquinone derivatives were isolated from the Iraqi rhubarb, Rheum ribes root by preparative TLC, their structures were identified by 1H NMR and used as standards for HPLC analysis. The percentages of alo
... Show MoreBanned temporarily divers has increased greatly in the society and for silly reasons.
This issue aroused a great controversy .There are so many motivations to Aleve deep in it.
There are so many approach hes to talk it . It deserves to be studied in a simple way but
thoroughly and comprehensively .Dune to this great importees and to its spread among
married couples for their agnorance concerning its voles' and dangers .
I have been stimulated and encouraged to go through and close read its details
aleomplish this research.
It is a olevided in to an introduction and three chapters :
1-chapter one : defines the terminology of banned temporarily clearer's and it legal situation .
2-chapter two : Terms of banned te
A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res
... Show MoreEthnographic research is perhaps the most common applicable type of qualitative research method in psychology and medicine. In ethnography studies, the researcher immerses himself in the environment of participants to understand the cultures, challenges, motivations, and topics that arise between them by investigating the environment directly. This type of research method can last for a few days to a few years because it involves in-depth monitoring and data collection based on these foundations. For this reason, the findings of the current study stimuli the researchers in psychology and medicine to conduct studies by applying ethnographic research method to investigate the common cultural patterns language, thinking, beliefs, and behavior
... Show More