The Hubble telescope is characterized by the accuracy of the image formed in it, as a result of the fact that the surrounding environment is free of optical pollutants. Such as atmospheric gases and dust, in addition to light pollution emanating from industrial and natural light sources on the earth's surface. The Hubble telescope has a relatively large objective lens that provides appropriate light to enter the telescope to get a good image. Because of the nature of astronomical observation, which requires sufficient light intensity emanating from celestial objects (galaxies, stars, planets, etc.). The Hubble telescope is classified as type of the Cassegrain reflecting telescopes, which gives it the advantage of eliminating chromatic aberration. Zemax optical design program was used to simulate the design of the Hubble telescope with nanosensors eyepiece, and to evaluate its performance through a set of analysis tools in the program, by changing some of the optical parameters that affect the performance of the telescope. The results proved needing of the imaging optical system (telescope) to align the observed object to avoid off-axial aberration. When the angle of incidence of the rays is changed to an appropriate extent, the image is negatively affected as a result of the increase in the amounts of aberration in it. The simulation also showed the similarity of the optical parameters that are related to the engineering design to get the best picture, through the analysis tools used in the program. Keywords: Reflective telescope, Nano sensors, Hubble, optical efficiency, Zemax program.
Background: Failure of resin bases were a major disadvantage recorded in the constructed dentures. Reinforcements of the repair joint with nano fillers represent an attempt to enhance the strength and durability. The purpose of the research was to estimate the influence of nano fillers reinforcement with (ZrO2 and Al2O3) on impact and transverse strength of denture bases repaired with either cold or hot processing acrylic resin. Materials and methods: A hundred and forty (140) samples were processed with hot cured resin and organized in subgroups depending on the repair materials and condition (without repair (control), repair with hot cure, cold cure, hot and cold cure reinforced with either (5% Zr2O or 0.5% Al2O3). The samples in these
... Show MoreThis work presents the study of the dark current density and the capacitance for porous silicon prepared by photo-electrochemical etching for n-type silicon with laser power density of 10mw/cm2 and wavelength (650nm) under different anodization time (30,40,50,60) minute. The results obtained from this study shows different chara that different characteristic of porous diffecteristics for the different porous Silicon layers.
Nano gamma alumina was prepared by double hydrolysis process using aluminum nitrate nano hydrate and sodium aluminate as an aluminum source, hydroxyle poly acid and CTAB (cetyltrimethylammonium bromide) as templates. Different crystallization temperatures (120, 140, 160, and 180) 0C and calcinations temperatures (500, 550, 600, and 650) 0C were applied. All the batches were prepared at PH equals to 9. XRD diffraction technique and infrared Fourier transform spectroscopy were used to investigate the phase formation and the optical properties of the nano gamma alumina. N2 adsorption-desorption (BET) was used to measure the surface area and pore volume of the prepared nano alumina, the particle size and the morphology of the surface of
... Show MoreNano materials have a great potential for enhanced oil recovery applications. The present research investigated the effect of nanoparticles on interfacial tension and wettability alteration. The silica oxide nanoparticles with different size 52, 65 and 5nm were used. The wettability alteration was evaluated by dipping the limestone rock in different concentrations of Nano silica (0.01-1wt. %) for a certain silica size suspended in salinity water. Measurements performed in three phase system (oil/water/solid) using pandel droplet and sessile drop method respectively by opitical-tensiometer. Results showed that Nano fluid can significantly reduce contact angle and alterated rock wettabi
The physician's commitment to medical insight is affected by several factors that vary from patient to patient in terms of the nature of the disease, the severity of the disease, the age of the patient, and the purpose of undergoing medical intervention. There are circumstances surrounding patients that require the physician to reduce the insight towards them, by concealing medical information. The physician must firmly commit to expanding the scope of his vision to a wider extent than in normal medical work. Therefore, we will discuss in this regard the cases in which medical explanation is reduced and the cases that require confirmation in the following order.
For the graph , the behavior associated with to the majority of the graphical properties of this graph is covered in this article. The reflection of the capabilities of on the Ly constructions is one of the key ideas addressed throughout this paper. For instance, by this technique we can comprehend the mechanism via which groups of relatively tiny structure are exist within Ly.
Polyaniline films were successfully synthesized in this study using an oxidative polymerization method at temperatures ranging from 0 to 4 ° C. Polyaniline films were deposited using a single step of chemical oxidative polymerization rather than electrochemical polymerization. The polyaniline was examined using FTIR, XRD, SEM, AFM, and Four Point Probe. This result demonstrates that polyaniline synthesized using this method has a uniform morphology, small size (17 to 40) nm, high crystallinity, and high conductivity (9.42 s/cm).
Thin films of cadmium sulphoselenide (CdSSe) have been prepared by a thermal evaporation method on glass substrate, and with pressure of 4x10-5 mbar. The optical constants such as (refractive index n, dielectric constant ?i,r and Extinction coefficient ?) of the deposition films were obtained from the analysis of the experimental recorded transmittance spectral data. The optical band gap of (CdSSe) films is calculate from (?h?)2 vs. photon energy curve. CdSSe films have a direct energy gap, and the values of the energy gap were found to increase when increasing annealing temperature. The band gap of the films varies from 1.68 – 2.39 eV.
The study effect Graphene on optical and electrical properties of glass prepared on glass substrates using sol–gel dip-coating technique. The deposited film of about (60-100±5%) nm thick. Optical and electrical properties of the films were studied under different preparation conditions, such as graphene concentration of 2, 4, 6 and 8 wt%. The results show that the optical band gap for glass-graphene films decreasing after adding the graphene. Calculated optical constants, such as transmittance, extinction coefficient are changing after adding graphene. The structural morphology and composition of elements for the samples have been demonstrated using SEM and EDX. The electrical properties of films include DC electrical conductivity; we
... Show MoreTheatrical techniques took upon themselves the responsibility of building and organizing the theatrical form for the various forms of performances, and it was the important tool that the show makers could rely on in carrying out the various works at the audio-visual level, and lighting is one of the most important elements of the visual formation of the image in the show, as it is related to the visual process and what it can achieve in operations The contrast that constitutes the aesthetic and intellectual values of the theatrical show, especially since the process of adjusting the element of time and the timings for receiving or delivering, moving, and the movement of the actor is what can determine the rhythm of the scene, which in it
... Show More