Chromium Ions Removal by Capacitive Deionization Process – Optimization of the Operating Parameters with Response Surface Methodology
...Show More Authors

An innovative desalination method called electrosorption or capacitive deionization (CDI) has significant benefits for wastewater treatment. This process is performed by using a carbon fiber electrode as a working electrode to remove hexavalent chromium ions from an aqueous solution. The pH, NaCl concentration, and cell voltage were optimized using the Box-Behnken experimental design (BDD) in response surface methodology (RSM) to study the effects and interactions of selected variables. To attain the relationship between the process variables and chromium removal, the experimental data were subjected to an analysis of variance and fitted with a quadratic model. The optimum conditions to remove Cr(VI) ions were: pH of 2, a cell voltage of 4.3V, and NaCl concentration of 1.4 g/L. This study demonstrated that the carbon fiber electrode was very efficient in Cr(VI) ions removal and the BBD methodology was a practical and effective strategy for predicting the results of various experimental conditions during a CDI process for the removal of chromium ions.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Feb 01 2022
Journal Name
Baghdad Science Journal
New Tetra-dentate Schiff Base Ligand N2O2 and Its Complexes with Some of Metal Ions: Preparation, Identification, and Studying Their Enzymatic and Biological Activities
...Show More Authors

In present work, new tetra-dentate ligand, titled 3,5-bis ((E)-5-Bromo-2-hydroxy benzylidene amino) benzoic acid (H3L), was prepared via an acid-catalyzed condensation process. New four metallic ligand complexes with Co(II), Ni(II), Cu(II) and Zn(II) ions, were also prepared from the refluxing of equivalent moles. Ligand's structure and its complexes; were confirmed by numerous characterization methods, including Ultraviolet-Visible, Infrared, Mass Spectrometer, 1H and 13C Nuclear Magnetic Resonance spectra, atomic absorption, magnetic moments, and molar conductivity measurements. The results of the spectroscopic analyzes proved that the prepared ligand acts as tetradentate bi-ionic ligand and it was bond

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Sep 01 2011
Journal Name
Journal Of Economics And Administrative Sciences
Analysis of the indicators of the educational process and scientific levelUsing the analysis of variance of ordered data in repeated measurements
...Show More Authors

In this research want to make analysis for some indicators and it's classifications that related with the teaching process and the            scientific level for graduate studies in the university by using analysis of variance for ranked data for repeated measurements instead of the ordinary analysis of variance . We reach many conclusions  for the                         

important classifications for each indicator that has affected on   the teaching process.         &nb

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 28 2020
Journal Name
Iraqi Journal Of Science
Synthesis and Characterization of New Polymers Bearing Tetrazole and Triazole Moieties with Studying their Corrosion Protection of Stainless Steel Surface in Hydrochloric Acid
...Show More Authors

A series of polymers containing1,2,4-triazole  and tetrazole groups in their main chains were synthesized through several steps. Poly(acryloyl hydrazide) was first prepared and then subjected to a hydrazide reaction with phenyl isothiocyanate to give a 1,2,4-triazole ring (2). This polymer was introduced into a reaction with chloro acetylchloride to yield polymer (3), which was refluxed with sodium azide to give polymer (4). Polymer (5) was synthesized by the reaction of polymer (4) with  acrylonitrile in the presence of NH4Cl as a catalyst. Finally, polymer (6) was synthesized by the electrochemical polymerization of polymer (5) using  316L stainless steel as an anti-corrosion coating. Polymer-coated and uncoat

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (3)
Scopus Crossref
Publication Date
Sat Oct 14 2023
Journal Name
Environmental Monitoring And Assessment
The technique of arsenic elimination from contaminated soil with enhanced conditions by electro-kinetic remediation
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Bulletin Of National Institute Of Health Sciences
Using of Propolis on the treated rats induced with Polysystic ovarian syndrome by Litrozol drug
...Show More Authors

View Publication
Publication Date
Sat Sep 23 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Nirite By The Diazotization Coupling With Aniline and 4,6 Dihydroxy-2 Mercaptopyrimidine
...Show More Authors

A direct  spectrophotometric method  has  been  developed  for  the

determination of nitrite  in aqueous  solution.  The method  is based on the  reaction  of  the nitritw  ion with an acidified  anline  solution from diazonium  cation   , which   is   subsequently  coupled   Â·with  4,6   - dihydroxy- 2- mercapto  pyrimidine to from yellow colored  and water

- soluble  intense  azo dye  with maximum  absorption at  416nm  . A

graph  of  absorbance  versus  concentration  shows   that  Bee's

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 18 2019
Journal Name
Baghdad Science Journal
Detecting Keratoconus by Using SVM and Decision Tree Classifiers with the Aid of Image Processing
...Show More Authors

 Researchers used different methods such as image processing and machine learning techniques in addition to medical instruments such as Placido disc, Keratoscopy, Pentacam;to help diagnosing variety of diseases that affect the eye. Our paper aims to detect one of these diseases that affect the cornea, which is Keratoconus. This is done by using image processing techniques and pattern classification methods. Pentacam is the device that is used to detect the cornea’s health; it provides four maps that can distinguish the changes on the surface of the cornea which can be used for Keratoconus detection. In this study, sixteen features were extracted from the four refractive maps along with five readings from the Pentacam software. The

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Jul 28 2018
Journal Name
Journal Of Engineering
Experimental Investigation for the Removal of Toxic Gases from Vehicle Exhaust using Non-Thermal Plasma
...Show More Authors

In this study, the use of non-thermal plasma theory to remove toxic gases emitted from a vehicle was experimentally investigated. A non-thermal plasma reactor was constructed in the form of a cylindrical tube made of Pyrex glass. Two stainless steel rods were placed inside the tube to generate electric discharge and plasma condition, by connecting with a high voltage power supply (up to 40 kV). The reactor was used to remove the contaminants of a 1.25-liter 4-cylinder engine at ambient conditions. Several tests have been carried out for a ranging speed from 750 to 4,500 rpm of the engine and varying voltages from 0 to 32 kV. The gases entering the reactor were examined by a gas analyzer and the gases concentration ratio

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Reverse Osmosis Polyamide Membrane for the Removal of Blue and Yellow Dye from Waste Water
...Show More Authors

The present work aims to study the removal of dyes from wastewater by reverse osmosis process. Two dyes were used direct blue 6, and direct yellow. Experiments were performed with feed concentration (75 – 450 ppm), operation temperature (30 – 50 oC) and time (0.2 – 2.0 hr). The membrane used is thin film composite membrane (TFC). It was found that modal permeate concentration decreases with increasing feed concentration and time operating, while permeate concentration increases with increasing feed temperature. Also it was found that product rate increase with increasing temperature, but it decrease with increasing feed concentration and time. The concentration of reject solution showed an increase with increasing feed concentratio

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance of Plate-Electrostatic Precipitator for Removal of R.M.O.C. Dust