Background:Plant-derived compounds have action alongside Gram-positive and Gram-negative bacteria and numerous compounds, inhibit efflux pumps and hence have become known as efflux pump inhibitors. Clarithromycin is a macrolide antibiotic used to treat pharyngitis, tonsillitis, acute maxillary sinusitis and acute bacterial exacerbation of chronic bronchitis the antibacterial range is the similar as erythromycin but it is active against Mycobacterium avium complex, M.leprae and atypical mycobacteria. The in vitro antibacterial activity results of different boswellic acid compounds discovered alpha keto-boswellic acid (AKBA) to be the preponderance potent antibacterial compound alongside Gram-positive pathogens, but it showed no significant antibacterial activity (MIC >128 μg/ml) against the Gram negative bacteria. Aim: The aim of present study, is to illustrate the effectiveness of Boswellia carteri against Gram positive and negative bacteria alone and in combination with clarithromycine to elucidate the synergestic antibacterial effects and how Boswellia carteri modifying the antibacterial activity of clarithromycine. Material and methods: The bacteria strains used in this study included five Gram-positive bacteria (Staphylococcus aureus, Streptococcus faecalis, Bacillus cereus, Staphylococcus epidermidis, Staphylococcus saprophyticus) and three Gram-negative bacteria (Klebsiella pneumoniae and Escherichia coli and Pseudomonas aeruginosa) five for each strains. Antibacterial activities were evaluated by measuring inhibition zone diameters by Agar-well diffusion,while Broth dilution method determine MIC.
Non-thermal or cold plasma create many reactive species and charged particles when brought into contact with plant extracts. The major constituents involve reactive oxygen species, reactive nitrogen species and plasma ultra-violets. These species can be used to synthesize biologically important nanoparticles. The current study addressed the effect of the green method-based preparation approach on the volumetric analysis of Zn nanoparticles. Under different operating conditions, the traditional thermal method and the microwave method as well as the plasma generation in dielectric barrier discharge reactor were adopted as a preparation approach in this study. The results generally show that the type of method used plays an important rol
... Show MoreFour metal complexes mixed ligand of 2-aminophenol (2-AP) and tributylphosphine (PBu3) were produced in aqueous ethanol with (1:2:2) (M:2-AP:PBu3). The prepared complexes were identified by using flame atomic absorption, FT.IR and UV-Vis spectroscopic methods as well as magnetic susceptibility and conductivity measurements. In addition antibacterial activity of the two ligands and mixed ligand complexes oboist three species of bacteria were also examined. The ligands and their complexes show good bacterial activities. From the obtained data the octahedral geometry was suggested for all prepared complexes. Keywords: Mixed ligand complexes, spectral studies, 2-aminophenol, tributylphosphine.
Four metal complexes mixed ligand of 2-aminophenol (2-AP) and tributylphosphine (PBu3) were produced in aqueous ethanol with (1:2:2) (M:2-AP:PBu3). The prepared complexes were identified by using flame atomic absorption, FT.IR and UV-Vis spectroscopic methods as well as magnetic susceptibility and conductivity measurements. In addition antibacterial activity of the two ligands and mixed ligand complexes oboist three species of bacteria were also examined. The ligands and their complexes show good bacterial activities. From the obtained data the octahedral geometry was suggested for all prepared complexes.
Background: Developing Goalkeeper’s performance is imperative to defence the goal. As the Football match’s nature needs implementning the skill with strength, and speed. so, the Goalkeeper demands special physical abilities that enabling him the ball blocking skill masterly. Objetive: The study aimed to identify the effect of developing some special physical abilities on the goalkeeper’s performance level while blocking executed balls from the penalty mark in football using plyometric training. Methodology: The experimental approach (continuous training that divided into two phases: General preparation, and Special preparation stage) was adopted for one experimental group by pre/post-measurements. The research sample was delib
... Show MoreThree hundred samples of washing water of vegetables were collected from women aged ( 15- 6o) years from different area in Baghdad governorate and its suburbs include two rural area ( Jaddria in Baghdad university and Al –Wagif in Rashdia) and two urbane area (Mansoure and Escan) . The samples were examined by precipitation method and then by staining method ( Lugols –Iodine stain) . The percentage of infection of intestinal parasites 36.3% include 15.3% for urban area and 57.3% in rural area and a significant difference was found between those groups . .The results showed also increased in the prevalence of parasitic infection in group age (15 -30) year .Also the results showed only 109 sample infected with eight specie
... Show MorePurpose To test the effect of strategic Supremacy on strategic success A case study in Thi Qar Governorate, methodology/approach – this is a mandatory entry.
a case study was used and applied to the Department managers of Government of the province of Thi Qar, Research limitations/implications – It is clear that the strategic Supremacy variable is not being used effectively to achieve strategic success.
Practical implications – use strategic supremacy positively to Support for strategic success. implementing and monitoring ignorance of them in how to use thi
... Show MoreVarious approaches are employed to enhance the heat transfer coefficient and Nusselt number inside the channels. One of the techniques employed for these enhancements is the utilization of porous media. In the current article, a practical investigation of forced convection heat transfer in a rectangular cross‐section channel (0.05 × 0.1 m2) with 0.25 m length is conducted. A heater with a heat flux range (450–6000 W/m2) is imposed under a copper plate, and the other sides are covered by insulation layers. The air is considered as a working fluid with