Preferred Language
Articles
/
ohcwdo8BVTCNdQwCFXjW
Spectrophotometric Determination of Nifedipine in Pharmaceutical Tablets Using Batch and Flow Injection Method Via Diazotization Coupling Reaction
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Wed Mar 08 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Carbamazepine Via Oxidative Coupling Reaction with 2,4-dinitrophenyl hydrazine
...Show More Authors

An accurate and sensitive spectrophotometric method has been developed for the determination of carbamazepine (CRN.) in pure and dosage forms. The method is based on the oxidation of 2,4-dinitrophenylhydrazine (2,4-DNPHz) by potassium periodate than coupling with carbamazepine (CRN.) in alkaline medium to form a stable yellowish brown colored water-soluble dye with a maximum absorption at 485 nm. The variables that affect the completion of reaction have been carefully optimized. Beer’s law is obeyed over the concentration range of (4-50 μg.mL-1) with molar absorptivity of (6.7335×103 L.mol-1.cm1). The limit of detection was (0.1052 μg.mL-1) and Sandell’s sensitivity value was 0.0350 μg.cm-2.The proposed method

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 08 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Carbamazepine Via Oxidative Coupling Reaction with 2,4-dinitrophenyl hydrazine
...Show More Authors

 An accurate and sensitive spectrophotometric method has been developed for the determination of carbamazepine (CRN.) in pure and dosage forms. The method is based on the oxidation of 2,4-dinitrophenylhydrazine (2,4-DNPHz) by potassium periodate than coupling with carbamazepine (CRN.) in alkaline medium to form a stable yellowish brown colored water-soluble dye with a maximum absorption at 485 nm. The variables that affect the completion of reaction have been carefully optimized. Beer’s law is obeyed over the concentration range of     (4-50 μg.mL-1) with molar absorptivity of (6.7335×103 L.mol-1.cm1). The limit of detection was (0.1052 μg.mL-1) and Sandell’s sensitivity value was 0.0350 μg.cm-2.

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 03 2012
Journal Name
Baghdad Science Journal
Batch and Flow-Injection Spectrophotometric Determination of Thymol Using Procaine Hydrochloride as a New Chromogenic Reagent
...Show More Authors

New, simple and sensitive batch and Flow-injecton spectrophotometric methods for the determination of Thymol in pure form and in mouth wash preparations have been proposed in this study. These methods were based on a diazotization and coupling reaction between Thymol and diazotized procaine HCl in alkaline medium to form an intense orange-red water-soluble dye that is stable and has a maximum absorption at 474 nm. A graphs of absorbance versus concentration show that Beer’s law is obeyed over the concentration range of 0.4-4.8 and 4-80 µg.ml-1 of Thymol, with detection limits of 0.072 and 1.807 µg.ml-1 of Thymol for batch and FIA methods respectively. The FIA procedure sample throughput was 80 h-1. All different chemical and physical e

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Feb 08 2023
Journal Name
Iraqi Journal Of Science
Spectrophotometric Determination of Vancomycin Hydrochloride (Batch and Flow-Injection) Using O-Nitroaniline as diazotized Chromogenic Reagent
...Show More Authors

New, simple and sensitive batch and nFIA spectrophotometric methods for the determination of Vancomycin Hydrochloride in pure form and in pharmaceutical preparations were proposed, These method's were based on diazotization and coupling reaction between Vancomycin Hydrochloride and diazotized O-nitroaniline in alkaline medium to form Orange water-soluble dye that is stable and has a maximum absorbance at 465nm. Acalibration graph shows that aBeer's law is obeyed over the concentration range of 0.8-60 and 5-400 μg.mL-1 of Vancomycin Hydrochloride with detection limit's of 0.16 and 1.666 μg.mL-1 of Vancomycin Hydrochloride for batch and nFIA methods, respectively. The FIA procedure sample throughput was 80 h-1. All different chemicals an

... Show More
View Publication Preview PDF
Publication Date
Fri Nov 24 2023
Journal Name
Iraqi Journal Of Science
Normal and Reverse Flow Injection- Spectrophotometric Determination of Vancomycin Hydrochloride in Pharmaceutical Preparations Using 2, 4-Dinitrophenylhydrazine
...Show More Authors

Simple and sensitive batch and flow injection methods (normal and reverse flow injection analysis (nFIA and rFIA)) for spectrophotometric determination of vancomycin hydrochloride (VHC) in pharmaceutical preparations were proposed and optimized. Both methods are based on the oxidative - coupling reaction between vancomycin hydrochloride and 2,4-Dinitrophenylhydrazine (DNPH) in the presence of sodium periodate in alkaline medium to form a yellow water-soluble product that is stable and has a maximum absorption at 461 nm. Beer’s law was obeyed over the range of 1- 40, 0.5-120 and 0.5-150 μg.mL-1; the limits of detection were 0.537, 0.0823 and 0.233 μg.mL-1 for batch, normal and reverse flow injection methods respectively. The sampling

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 12 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Sulfamethoxazole Following Simple Diazotization and Coupling with Diphenylamine
...Show More Authors

    Simple, sensitive, accurate and inexpensive spectrophotometric methods have been developed for the determination of sulfamethoxazole (SMZ) in pure and dosage forms. This method is based on diazotization of primary amine group of sulfamethoxazole with sodium nitrite and hydrochloric acid followed by coupling with diphenylamine in acidic medium to obtain a stable blue colored dye and show a maximum absorption (max) at 530 nm. Different variables affecting the completion of reaction have been carefully optimized, following the classical univariate sequence and modified simplex method. Beer’s law is obeyed in the concentration range of (0.5-12.0 µg.mL-1) with molar absorptivity of 4.9617×104 L.mol-1.cm-1. The

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 25 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Spectrophotometric Determination of Cefixime Following Simple Diazotization and Coupling with ?-Naphthol
...Show More Authors

Cefixime (CFX) was treated with sodium nitrite and hydrochloric acid for diazotization reaction followed by coupling with ?-Naphthol in alkaline medium to form, a yellow colored azo dye compound which exhibits maximum absorption (?max) at 412 nm where the concentration of (CFX) was determined spectrophotometrically. The optimum reaction conditions and other analytical parameters were evaluated. Beer’s law was obeyed in the concentration range of (1-20) ?g.mL-1 with a molar absorptivity of 34870.5 L.mol-1.cm-1. The limit of detection was found to be 0.1090 ?g.mL-1 and the Sandell's sensitivity value was 0.0130 ?g.cm-2. The proposed method could be successfully applied to

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 25 2020
Journal Name
International Journal Of Drug Delivery Technology
Simultaneous Determination of Trace Mefenamic Acid in Pharmaceutical Samples via Flow Injection Fluorometry
...Show More Authors

Mefenamic acid belongs to non-steroidal anti-inflammatory drugs that are used widely for the treatment of analgesia. Our aim from this study is to establish a new assay for the quantitative determination of mefenamic acid (MFA) in the pharmaceutical sample by two sensitive and rapid flow injection-fluorometric methods. A homemade fluorometer was used in fluorescence measurements, which using solid-state laser diode 405 and 532 nm as a source, combined with a continuous flow injection technique. The first method depends on the effect of MFA on calcein blue (CLB) fluorescence at 405 nm. Another method is a study of rhodamine-6G (Rh-6G) fluorescence after adding MFA, and recording at 532 nm. Optimum parameters as fluorescent dye concen

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Sat Oct 28 2023
Journal Name
Baghdad Science Journal
Indirect Flow Injection Spectrophotometric and Chromatographic Methods for the Determination of Mebendazole in Pharmaceutical Formulations
...Show More Authors

Chromatographic and spectrophotometric methods for the estimation of mebendazole in
pharmaceutical products were developed. The flow injection method was based on the oxidation of
mebendazole by a known excess of sodium hypochlorite at pH=9.5. The excess sodium hypochlorite is then
reacted with chloranilic acid (CAA) to bleach out its color. The absorbance of the excess CAA was recorded
at 530 nm. The method is fast, simple, selective, and sensitive. The chromatographic method was carried out
on a Varian C18 column. The mobile phase was a mixture of acetonitrile (ACN), methanol (MeOH), water
and triethylamine (TEA), (56% ACN, 20% MeOH, 23.5% H2O, 0.5% TEA, v/v), adjusted to pH = 3.0 with
1.0 M hy

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Apr 24 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Use of Acidic Hydrolysis and Diazo Coupling Reaction for Spectrophotometric Determination of Furosemide in Urine and Pharmaceutical Formulation.
...Show More Authors

     Simple and rapid spectrophotometric determination of furosemide (FUR) has been investigated .The method is based on acid hydrolysis of FUR to free primary aromatic amine and diazotization followed by coupling with 3, 5 di methyl phenol (3, 5-DMPH) at basic medium. The absorbance was measured at 434 nm, the method was optimized for best condition, and beers’ law is obeyed over the range of 0.4-50 µg.mL-1 with molar absorptivity and sandal’s sensitivity 1.3899 x104 L moL-1 .cm-1 and 0.0238x104 µg.cm-2 respectively. Analysis of solution containing nineteen different concentrations of FUR gave a correlation coefficient of (0.9999) a

... Show More
View Publication Preview PDF
Crossref (2)
Crossref