This current study was built on creating four electrodes based on molecularly imprinted polymers (MIPs). As the template using Cefalexin (CFX), 1-vinyl imidazole (VIZ) and vinyl acetate (VA) as monomer, and N, N-methylene bis acrylamide (MBAA) as cross-linkers and benzoyl peroxide as the initiator, two MIPs were prepared. The same composition was used in non-impressed polymers (NIPs) preparation, but without the template (Cefalexin). For the membranes preparation, numerous plasticizers, such as tri-oly phosphate (TOP) and di-octyl phthalate (DOP), were used in the PVC matrix, slop, detection limit, lifetime, and linearity range of CFX-MIPs electrodes are characteristics &nb
... Show MoreTwo simple and sensitive spectrophotometric methods are proposed for the determination of amitriptyline in its pure form and in tablets. The first method is based on the formation of charge- transfer complex between amitriptyline as n-donor and tetracyano-ethylene (TCNE) as πacceptor. The product exhibit absorbance maximum at 470 nm in acetonitrile solvent (pH =9.0 ) . In the second method the absorbance of the ion- pair complex, which is formed between the soughted drug and bromocresol green (BCG), was measured at 415 nm at ( pH=3.5) . In addition to classical univariate optimization, modified simplex method (MSM) was applied in the optimization of the variable affecting the color producing reaction by a geometric simple
... Show MoreThe present study include a new developed method of analysis for determination of drug Spironolaction (SP) in some Pharmaceuticals by Spectrofluorometric method. Spironolaction was determined under optimal experimental condition that follows :- The excitation spectrum was (l=351 nm), the emmetion spectrum was (l=518 nm), pH=1, the suitable temperature for reaction 60oC and the optimal time less than (3) minute. The analysis and rang statistical data was:-Linear dynamic rang (1-10) ?g.ml-1, the detection limit (D.L = 0.023 ?g.ml-1), Molar absorptivity (? = 29875 liter mole-1 cm-1), Relative standard deviation (%RSD = 0.78), (%Erel = 3.3) and recovery (Rec = 96.6) percentage. Determination of Spironolactone was accomplished by two methods
... Show MoreTwo new simultaneous spectrophotometric methods for determination of Olanzapine and Ephedrine depend on third (D3) and fourth (D4) derivative of zero spectrum of two drugs were developed. The peak – to- base line, peak to peak and area under peak were found proportional with concentration of the drugs up to (4-24 µg/ml-1) at known experimental wavelengths. The results showed that the method was precise and accurate through RSD% (0.5026-4.0273),( 0.2399 6.9888) and R.E %(-2.3889-0.8333) ,) -2.9444-0.2273) while the LOD (0.0057- 0.8510 μg.ml-1), ( 0.0953-0.9844 μg.ml-1) and LOQ (0.0173- 2.5788μg.ml-1),( 0.5774-2.9829 μg.ml-1) were found for the two drugs respectively. The methods were applied i
... Show MoreTwo quantitative, environment-friendly and easily monitored assays for Ni (II) and Co (III) ions analysis in different lipstick samples collected from 500-Iraqi dinars stores located in Baghdad were introduced. The study was based on the reaction of nickel (II) ions with dimethylglyoxime (DMG) reagent and the reaction of cobalt (III) ions with 1-nitroso-2-naphthol (NN) reagent to produce colored products. The color change was measured by spectrophotometric method at 565 nm and 430 nm for Ni and Co, respectively, with linear calibration graphs in the concentration range 0.25-100 mg L-1 (Ni) and 0.5-100 mg L-1 (Co) and LOD and LOQ of 0.11 mg L-1 and 0.36 mg L-1 (Ni), and 0.15 mg L-1 an
... Show MoreRapid, reproducible and accurate method has been developed for the assay for of mebendazol (MBZ) residual assay. The method is based on alkaline hydrolysis of MBZ with sodium hydroxide then oxidation with N-bromosuccinimide (NBS) followed by coupling with 4-Bromoaniline (4-BA) to yield a highly colored product absorbed at maximum 434 nm. Regression analysis of linearity range was found (0.6-2.8) µg.ml-1. The optimum conditions that affect the oxidation were studied. The developed method was found to be precise with mean value of relative standard deviation (1.153- 1.303) and accurate with relative error (-0.5940-1.7821) .The calculated molar absorptivity and sandal sensitivity values of (29825 L.mol-1.cm-1), 0.0099 µg.cm-2 respe
... Show MoreRapid, reproducible and accurate method has been developed for the assay for of mebendazol (MBZ) residual assay. The method is based on alkaline hydrolysis of MBZ with sodium hydroxide then oxidation with N-bromosuccinimide (NBS) followed by coupling with 4-Bromoaniline (4-BA) to yield a highly colored product absorbed at maximum 434 nm. Regression analysis of linearity range was found (0.6-2.8) µg.ml-1. The optimum conditions that affect the oxidation were studied. The developed method was found to be precise with mean value of relative standard deviation (1.153- 1.303) and accurate with relative error (-0.5940-1.7821) .The calculated molar absorptivity and sandal sensitivity values of (29825 L.mol-1.cm
... Show MoreA simple indirect spectrophotometric method for determination of mebendazol in pure and pharmaceutical formulation was presented in this study. UV-Visible spectrophotometry using the optimal conditions was developed for determination of mebendazole in pure drug and different preparation samples. The method is based on the oxidation of drug by nbromosuccinimide with hydrochloric acid and the left amount of oxidizing agent was determined by the reaction with tartarazine and the absorbance was measured at 428 nm. Calibration curves were linear in the range of 5 to 30 µg.mL-1 with molar absorptivity 8437.2 L.mol-1 .cm-1 . The limits of detection and quantification were determined and found to be 0.7770 µg.mL-1 and 2.3400 µg.mL-1 respec
... Show MoreCeftriaxone sodium were one of the widely antibacterial drugs used. Azo dye derivatization of diazonium salt that formed via the reaction between ceftriaxone with hydrochloric acid and sodium nitrite was developed for the on-research drug analysis then coupling with each one 2,5-dimethylphenol (2,5-DMP) and 4-tertbutylphenol (4-TBP) respectively in the alkaline media. The developed diazonium coupling methods include an optimization study. The results show a limit of detection and limit of quantification 0.482, 0.284 µg/mL, and 1.607, 0.945 µg/mL using 2,5-DMP and 4-TBP reagents respectively. Moreover, the recovery % obtained was 100.89%, and 103.37% at linear concentration range 3.0 – 50, and 10 – 30 µg/mL, with mo
... Show More