Preferred Language
Articles
/
oRhQxJYBVTCNdQwCbIYt
Hydrophilic Interaction Chromatography Analysis of Esculin in Ointments with UV Detection
...Show More Authors
Background:

Esculin (ESCN) is used in the pharmaceutical industry with intravenous effect, stimulant and anti-inflammatory capillaries, like vitamin P. It is a significant component of many anti-inflammatory remedies such as esqusan, esflazid and anavenol [14]. It is also found in numerous other remedies available in the market such as proctosone, anustat, and ariproct.

Objective:

To determine experimental conditions, to elucidate retention behavior of esculin in HILIC mode. Moreover, to suggest new ways to separate and determinate esculin in ointments.

Methods:

Two hydrophilic columns were obtained by attaching molecules of sulfobetaine to polystyrene- divinylbenzene particles were studied for chromatographic separation of esculin. The various lengths of the chain are used as an investigative instrument for esculin retention conduct. The change of ACN percentage, buffer concentrations and pH of mobile phase in order to study the retention conduct of esculin.

Results:

A mixed mode hydrophilic interaction and ion exchange is the separation mechanism of esculin. A calibration graph was created for two columns. The concentration range was 8-1200 ng.ml-1, LOD 2.33 and 1.40, RSD% 0.31-1.02, , LOQ 7.07 and 4.25 ng.ml-1, Erel% 0.83 ± 0.68 and 0.545 ± 0.45, Recovery% 100.86 ± 0.68 and 1054 ± 0.45.

Conclusion:

The findings of the current study introduced new ZIC-HILIC methods for the separation and quantitation of esculin.

Scopus Clarivate Crossref
View Publication
Publication Date
Wed Oct 12 2011
Journal Name
Journal Of Liquid Chromatography & Related Technologies
RAPID DETERMINATION OF SPHINGANINE AND SPHINGOSINE IN URINE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY USING MONOLITHIC COLUMN
...Show More Authors

A rapid high performance liquid chromatography method for the determination of sphinganine (Sa) and sphingosine (So) in urine samples by employing a silica-based monolithic column is described. The samples were first extracted using ethyl acetate and derivatized using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol. C20 sphinganine was used as internal standard. Under the optimized conditions, separation was achieved using a mixture of methanol:water (93:7, v/v), column temperature at 30°C, flow rate of 1 mL min−1, and an injection volume of 10 μL. Good linearity was obtained for Sa and So over the concentration range 20–500 ng mL−1(correlation coefficients ≥0.9978). The detection limits were 0.45 ng mL−1 for Sa and

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Baghdad Science Journal
Artificial Neural Network and Latent Semantic Analysis for Adverse Drug Reaction Detection
...Show More Authors

Adverse drug reactions (ADR) are important information for verifying the view of the patient on a particular drug. Regular user comments and reviews have been considered during the data collection process to extract ADR mentions, when the user reported a side effect after taking a specific medication. In the literature, most researchers focused on machine learning techniques to detect ADR. These methods train the classification model using annotated medical review data. Yet, there are still many challenging issues that face ADR extraction, especially the accuracy of detection. The main aim of this study is to propose LSA with ANN classifiers for ADR detection. The findings show the effectiveness of utilizing LSA with ANN in extracting AD

... Show More
View Publication Preview PDF
Scopus (13)
Crossref (9)
Scopus Crossref
Publication Date
Mon Aug 01 2022
Journal Name
Baghdad Science Journal
Investigation of the Nuclear Structure of Some Ni and Zn Isotopes with Skyrme-Hartree-Fock Interaction
...Show More Authors

The inelastic C2 form factors and the charge density distribution (CDD) for 58,60,62Ni and 64,66,68Zn nuclei has been investigated by employing the Skyrme-Hartree-Fock method with (Sk35-Skzs*) parametrization. The inelastic C2 form factor is calculated by using the shape of Tassie and Bohr-Mottelson models with appropriate proton and neutron effective charges to account for the core-polarization effects contribution. The comparison of the predicted theoretical values was conducted with the available measured data for C2 and CDD form factors and showed very good agreement.

View Publication Preview PDF
Scopus (11)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Thu Jan 20 2022
Journal Name
Baghdad Science Journal
Investigation of the Nuclear Structure of Some Ni and Zn Isotopes with Skyrme-Hartree-Fock Interaction
...Show More Authors

Crossref (9)
Crossref
Publication Date
Fri Oct 11 2019
Journal Name
Journal Of The College Of Education For Women
The Symbolic Interaction of the Kindergarten
...Show More Authors

The Symbolic Interaction of the Kindergarten

View Publication Preview PDF
Publication Date
Fri Nov 19 2010
Journal Name
مجلة جامعة كربلاء
Interaction of Cysteine in aqueous Dimethylformamide solution at deferent temperatures
...Show More Authors

Publication Date
Wed Dec 30 2020
Journal Name
Journal Of Planner And Development
Function of Urban Space in strengthen social interaction through Time
...Show More Authors

problem of the research is the decline of the role of urban space with time as an influential system in societal relations. The research aims to define indicators for achieving social interaction in the city, and to determine indicators for achieving integration in the urban space, and to study the relationship between the integration of urban space and community interaction over time. the research assumed that by distinguishing the social interaction space from the urban space and developing urban spaces in order to be truly interactive spaces, this will help us achieve social interaction and build a positive relationship between them, which enables us to achieve integration within the urban spaces leading to social interaction. Because

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 23 2009
Journal Name
Journal Of College Of Education Al-mustansiriya University
Interaction of Thereonine in aqueous Dimethylformamide solution at deferent temperatures
...Show More Authors

Publication Date
Sun Apr 17 2016
Journal Name
Al-academy
Conditions The chromatography in the design the positions waiting passenger transport buses: مصعب حسن عبد
...Show More Authors

running the requirement color important place in object of life activity both public and private, Fallon makes represents energy expressive and aesthetic in designing furniture street, especially (positions waiting buses passenger transport)which took looms large in attention receiver designer also, through civilized development and urban and change the city. Requirement, The positions of waiting progress jobs service and that would interact to produces Photos aesthetic Furniture for space street and understand receiver, affect the operation his life and the development of his environment and his psyche and culture of because they entity variable and sophisticated, impose on us to find foundations a design and conditions of chromatic esp

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jul 01 2024
Journal Name
Iop Conference Series: Earth And Environmental Science
Assessment of Two Extraction Methods LLE and QUEChERS to Determine Pesticides Residues in Vegetables by Gas Chromatography
...Show More Authors
Abstract<p>The extraction of pesticides is a critical and urgent issue in the preparation for and determination of pesticide residues. The lack of a quick, easy, and successful extraction process is the most critical and challenging problem, even if diagnostic tools have improved and pesticide residues have been better understood. This study contrasted the QuEChERS method, which uses gas chromatography with a flame ionization detector, with the LLE method, which uses liquid-liquid extraction, in order to extract pyridaben from cucumbers and spiromesifen from tomatoes. The GC-FID device was employed to ascertain the spiromesifen LOD and LOQ, which were 0.002 μg mL<sup>-1</sup> and 0.00</p> ... Show More
View Publication
Scopus (1)
Crossref (2)
Scopus Crossref