Background: Chronic cigarette smoking is one of the major risk factors for coronary artery disease. However, it has additional cardiac adverse effects independent of coronary atherosclerosis. Patient and Methods: After informed consent and perm- ission from the review board of the hospital, 80 healthy subjects who were classified as smokers or non-smokers were included in the study. They were examined by standard echocardiography protocol which was followed by two-dimensional speckle tracking to assess the functions of the right ventricle. Results: The tricuspid annular plane systolic excursion (TAPSE) was significantly reduced in smokers as compared to non-smokers (P < 0.05). The tricuspid flow peak late diastolic velocity (A wave) was significantly higher in smokers (P < 0.05, and hence the E/A ratio was signif- icantly lower (P < 0.05). The tissue Doppler imaging examination of right ventricular free wall showed that the peak systolic velocity of right ventricular (RV) free wall (S’), and the peak early diastolic velocity of RV free wall (E’) were significantly lower in smokers when compared to the control group (P < 0.05 for both). The global longit- udinal strain (GLS) assessed by 2D-speckle tracking echo- cardiography was also significantly reduced in smokers (P < 0.05). Conclusion: This study demonstrates that chronic cigarette smoking causes alterations in long-axis systolic and diast- olic functions of right ventricle in healthy young subjects. These changes can be detected early with 2-D speckle tracking echocardiography.
Background: Mitral regurgitation (MR) is the most commonly encountered valve lesion in modern clinical practice. Severe mitral regurgitation may cause systolic dysfunction. Left ventricular ejection fraction may not be an accurate measurement of LV function in patients with mitral insufficiency. Myocardial performance index (MPI) is a simple non invasive measure of myocardial function. Methods: The study involved 50 patients with valvular mitral regurgitation and 50 healthy subjects as a control group. Transthoracic echocardiography was carried out for all patients and control group. The echocardiographic measurements included left ventricular end diastolic and end systolic dimensions, left atrial diameter, ejection fraction (EF), and myoca
... Show MoreABSTRACT: BACKGROUND: Left ventricular hypertrophy is a significant risk factor for cardiovascular complications such as ischemic heart disease, heart failure, sudden death, atrial fibrillation, and stroke. A proper non-expensive tool is required for detection of this pathology. Different electrocardiographic (ECG) criteria were investigated; however, the results were conflicting regarding the accuracy of these criteria. OBJECTIVE: To assess the accuracy of three electrocardiographic criteria in diagnosis of left ventricular hypertrophy in adult patients with hypertension using echocardiography as a reference test. PATIENTS AND METHODS: This is a hospital-based cross sectional observational study which included 340 adult patients with a his
... Show MoreGamma - irradiation effect on polymethylmethacrylate (PMMA) samples has been studied using Positron Annihilation Lifetime (PAL) method. The orthopositronium (o-Ps) lifetime τ3, hence the o-ps parameters, the volume hole size (Vh) and the free volume fraction (Ꞙh) in the irradiated samples were measured as a function of gamma-irradiation dose up to 28.05 kGy. It has been shown that τ 3, Vh, and Ꞙh, are increasing in general with increasing gamma-dose, to reach a maximum percentage increment of 22.42% in τ3, 60% in Vh and 29.5% in Ꞙh, at. 2.55 kGy, whereas τ2 reaches maximum increment of 119. 7% at 7.65 kGy. The results s
... Show MoreBackground:This is a prospective study of three children presented to us in the Orbital clinic in AL ShahidGazi Al Hariri Hospital with painless proptosiswith suspension of Hydatid disease.Objectives: : Orbital hydatid disease is a rare lesion accounting for less than 1% of the total lesions of the body (1, 2). Orbital cysts presented as a primary lesion in our study which is rare to have such lesion without involvement of other organs (3). Humans represent the intermediate host where the commonly affected organ are liver and the lung (10-15%) (4). Methods:This is a prospective study of three Children presented to us in the Orbital clinic in Al Shahid Ghazi Alhariri Hospital with painless proptosis with suspension of Hydatid disease, dep
... Show MoreBesides the role of state institutions that come in the forefront of their priorities and obligations to provide security and development of the economy and reduce the unemployment rate and the reduction of inflation and improving education, health and others, the Community Partnership At frames what has become known as the institutions of society civil-with the state does not eliminate the role, but rather complements its role ; it is the role of civil society partner and an extension of the role of the state in the face of challenges and crises, but it may be sometimes a race role in addressing social, political and economic issues of the role played by the state, not complementary.
The highlighting the specificity of the relationsh
MII Al-Itabi, WH Abdulameer, OSS Al-Mashhadani, Review of International Geographical Education Online, 2021 - Cited by 1
Objective. This study aimed to evaluate and compare the force degradation of two types of elastomeric chains following different periods of immersion in zinc-containing mouthwashes. Materials and Methods. Four hundred and forty pieces of Elasto-Force and Super Elasto-Force elastomeric chains were divided into two control and eight experimental groups. The pieces were stretched to 25 mm on pins mounted on an acrylic block and stored in distilled water at 37°C. The experimental groups were immersed in four different types of mouthwash for one minute twice a day throughout the test period. Ten continuous thermocycles per day between cold and hot water baths (5–55°C) were carried out. Forces were measured at six-time intervals (in
... Show MoreClinicians and investigators consider the normal range of bowel habit and frequency as between 3 to 21 motions per week. Stool frequency outside the normal range may be unusual but may not be abnormal in the sense of a disease, and according to the consistency, the normal stool ranges from porridge like to hard and pellety.
Objectives: To establish a basic data about the bowel habits (consistency and frequency) in a sample of healthy Iraqi population; in addition to learn about their definition of constipation and diarrhea.
Methods: Prospective study from Jan 2000- Jun 2000 at Al-Yarmouk teaching hospital, Baghdad. Questionnaires were distributed to 950 healthy persons of different age group .The questionnaire included: Detailed hi
Background: Clinicians and investigators consider the normal range of bowel habit and frequency as between 3 to 21 motions per week . Stool frequency out side the normal range may be unusual but may not be abnormal in the sense of a disease . And according to the consistency, the normal stool ranges from porridge like to hard and pellety .Objectives: To establish a basic data about the bowel habits (consistency and frequency) in a sample of healthy Iraqi population; in addition to learn about their definition of constipation and diarrhea.Methods: Prospective study from Jan 2000- Jun 2000 at Al-Yarmouk teaching hospital, Baghdad. Questionnaires were distributed to 950 healthy persons of different age group .The questionnaire included: Det
... Show MoreAtmospheric transmission is disturbed by scintillation, where scintillation caused more beam divergence. In this work target image spot radius was calculated in presence of atmospheric scintillation. The calculation depend on few relevant equation based on atmospheric parameter (for Middle East), tracking range, expansion ratio of applied beam expander's, receiving unit lens F-number, and the laser wavelength besides photodetector parameter. At maximum target range Rmax =20 km, target image radius is at its maximum Rs=0.4 mm. As the range decreases spot radius decreases too, until the range reaches limit (4 km) at which target image spot radius at its minimum value (0.22 mm). Then as the range decreases, spot radius increases due to geom
... Show More