This work provides a historical overview of water storage tanks used for solar energy collection, with a focus on the impact of different geometric configurations on thermal performance and energy storage efficiency. The designs of cylindrical, spherical, rectangular and triangular tanks were reviewed to analyse their effects on thermal gradients, heat retention and energy storage capacity. Within the scope of nominal processes, the study primarily aimed to identify the factors influencing the choice of tank shape in terms of size, capacity and aspect ratio. Another key objective was to assess what enhances heat storage in the tank to improve thermal efficiency. Comparing cylindrical shapes to other shapes, such as spherical, rectangular, and triangular , it offered the optimal performance with the needed requirements for the objects that have a smaller surface area-to-capacity ratio in addition to the lower heat loss. Furthermore,when the tilt angle with horizontal axes of the storage tank was at 0°, the tanks’ ratio reduction had remarkable impact on thermal stratification . The results might provide valuable information for the thermal storage system’sdesign in solar water heating for improving thermal efficiency. This work provides the basis for research exploiting high-temperature solar energy storage technologies and their applications in building sustainable energy systems.
The two-dimensional transient heat conduction through a thermal insulation of temperature dependent thermal properties is investigated numerically using the FVM. It is assumed that this insulating material is initially at a uniform temperature. Then, it is suddenly subjected at its inner surface with a step change in temperature and subjected at its outer surface with a natural convection boundary condition associated with a periodic change in ambient temperature and heat flux of solar radiation. Two thermal insulation materials were selected. The fully implicit time scheme is selected to represent the time discretization. The arithmetic mean thermal conductivity is chosen to be the value of the approximated thermal conductivity at the i
... Show MoreThe determination of river pollution impact on the performance of water treatment plants is achieved by two main objectives. The first is to study raw and treated water qualities and comparing them with standards and the second is to evaluate the treatment plants efficiency. The analyzed data were those water quality parameters in relation to physical, chemical and bacteriological characteristics for river water and produced water by seven water treatment plants located on Tigris River passing through Baghdad City.
The results of this study indicated that all raw water characteristic are within the surface water standards established by Iraqi and USA criteria except Bacterial Counts.
Tigris River water is of good quality to be trea
In this work, the annual behavior of critical frequency and electron density parameters of the ionosphere have been studied for the years (1989, 2001 and 2014) and (1986, 1996 and 2008) which represent the maximum and minimum of years in the solar cycles (22, 23 and 24) respectively. The annual behavior of (Ne, fo ) parameters have been investigated for different heights of Ionosphere layer (100 -1000) Km. The dataset was created both of critical frequency and electron density parameters by using the international reference ionosphere model (IRI-2016 model). This study showed result that during the maximum solar cycles the values of the (Ne) parameter change with
The aim of this research is to find the impact of the efficiency of Management information systems (MIS) on the effectiveness of governmental organizations performance.
To achieve the objective of the research, the analytical descriptive method was adopted. A questionnaire was designed consisting of (35) paragraphs, and the sample consisted of (200) individual. The research attemped to answer the following question: To achieve the objective of the research, the analytical descriptive method was adopted. A questionnaire was designed consisting of (35) paragraphs, and the sample consisted of (200) individual. The research tried to answer the following question: What is the actual utilization of modern admi
... Show MoreIn the postmodern era, the graphic design styles showed a new visualization method when the graphic designers had changed the traditional conditions by using design elements with new technics for photos, collage and comics illustration. The researcher assumes that the graphic design styles were affected by the art's movement at that period throw the same perspective of view for the concept presented in the art pieces and their entire message. Therefore, the researcher chooses field was the period of 1945-1970 in the USA for the (pop-art and conceptual-art) and explored the main visual effects that expressed the visual dialogue and compared them with the most common design styles ant the same period and location, the results of selected e
... Show Morel