Giardia lamblia is the worldwide most common intestinal protozoan parasite. It was indicated that Giardia is the most important agent that causes acute and chronic diarrhea in infants, young children and travelers. The aim was to detect the influence of host HLA alleles on the susceptibility to infection with G. lamblia in a sample of Iraqi patients. A total of (40) patients with giardiasis aged (14-39) years were registered. All of them were symptomatic and (40) healthy individuals matched age and sexes were included as controls. All patients were prepared to stool examination to detect G. lamblia and eliminated other pathogens, as well as human leukocyte antigen (HLA) class II alleles (DRB1) typing. The most common detected alleles in patients group were HLA-DRB1*03:0101, HLA-DRB1*13:0101,and HLA-DRB1*07:0101 compared to control group (P< 0.003; odds ratio (OR) 6.32; 95% confidence interval (CI) 2.35 to 28.03), secondly (P < 0.002; odds ratio (OR) 4.27; 95% confidence interval (CI) 1.64 to 8.05) and lastly (P< 0.001; odds ratio (OR) 3.54; 95% confidence interval (CI) 1.22 to 5.68) respectively. In conclusion HLA- DRB1*03:0101 alleles,*13:0101 alleles and 07:0101 alleles may affect human susceptibility to giardiasis
A simple, rapid and sensitive method for the analysis of Atenolol in pure and pharmaceutical preparation as an alternative analytical procedure were developed by continuous flow injection analysis via turbidimetric (T180o) and scattered light effect at two opposite position (2N90o). The method is based upon the formation of white precipitate for the ion pair compound by phosphomolybidic acid with Atenolol in aqueous medium. The precipitate is measured via the attenuation of incident light and scattering of the incident light in two opposite direction namely +90o and -90o angle were measured. Chemical and physical parameters were investigated. The linearity of Atenolol is ranged from (0.1-11) mmol.L-1, with correlation coefficient r=0.993
... Show MoreBackground: The COVID-19 pandemic has an immense effect not only on the social and economic lives of people but also on the surgical lives of surgeons, residents, nursing staff, and patients as well as ground level staff. Amidst this COVID pandemic, emergency surgeries were being done but at a decreased rate, whereas elective cases depended on the will of hospitals, surgeons, and patients. Study aims to promulgate a "Neo–Surgical Check Box" by amalgamating the WHO surgical checklist and the results obtained from the questionnaires.
Subjects and Methods: After receiving ethical clearance from the Institute Ethical Committee, an online questionnaire with 50 questions divided into
... Show MoreThis paper proposed a new method to study functional non-parametric regression data analysis with conditional expectation in the case that the covariates are functional and the Principal Component Analysis was utilized to de-correlate the multivariate response variables. It utilized the formula of the Nadaraya Watson estimator (K-Nearest Neighbour (KNN)) for prediction with different types of the semi-metrics, (which are based on Second Derivative and Functional Principal Component Analysis (FPCA)) for measureing the closeness between curves. Root Mean Square Errors is used for the implementation of this model which is then compared to the independent response method. R program is used for analysing data. Then, when the cov
... Show MoreThe effect of electrolysis operating parameters on the removal efficiency of cadmium from a simulated wastewater was studied by adopting response surface methodology combined with Box–Behnken Design. As a new electrode design, spiral-wound woven wire mesh rotating cylinder electrode was used for cadmium removal. Current (240–400 mA), rotation speed (200–1000 rpm), initial cadmium concentration (200–600ppm), and cathode mesh number (30–60) were chosen as independent variables while the removal efficiency of cadmium was considered as a response function. The results revealed that the rotation speed has the major effect on the removal efficiency of cadmium. Regression analysis showed good fit of the experimental data to the second-or
... Show MoreNew Schiff base ligand (E)-6-(2-(4-(dimethylamino)benzylideneamino)-2-(4-hydroxyphenyl)acetamido)-3,3- dimethyl-7-oxo-4-thia-1- azabicyclo[3.2.0]heptane-2-carboxylic acid = (HL) was synthesized via condensation of Amoxicillin and 4(dimethylamino)benzaldehyde in methanol. Figure -1 Polydentate mixed ligand complexes were obtained from 1:1:2 molar ratio reactions with metal ions and HL, 2NA on reaction with MCl2 .nH2O salt yields complexes corresponding to the formulas [M(L)(NA)2Cl],where M=Fe(II),Co(II),Ni(II),Cu(II),and Zn(II), A=nicotinamide .
The development of a reversed phase high performance liquid chromatography fluorescence method for the determination of the mycotoxins fumonisin B1 and fumonisin B2 by using silica-based monolithic column is described. The samples were first extracted using acetonitrile:water (50:50, v/v) and purified by using a C18 solid phase extraction-based clean-up column. Then, pre-column derivatization for the analyte using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol was carried out. The developed method involved optimization of mobile phase composition using methanol and phosphate buffer, injection volume, temperature and flow rate. The liquid chromatographic separation was performed using a reversed phase Chromolith® RP-18e column
... Show MoreIn the cuurent article, the photophysical properties of 3,6-bis(5-bromothiophen-2-yl)-2,5-bis(2-ethylhexyl)-2,5-dihydropyrrolo[3,4-c]pyrrole-1,4-dione were investigated. The visible absorption bands at 527, 558 and 362 nm in propylene carbonate and the compound was found to be fluorescent in solution and in the plastic film with emission wavelengths between 550- 750 nm. The Stokes Shift of P.C., acetonitrile, diethyl ether, Tetrahydrofuran THF, cyclohexane, dibutyl ether, and dichloromethane DCM are 734, 836, 668, 601, 601, 719, and 804 cm-1 in respectively. The Stokes Shift Δ was less in THF and cyclohexane, than the solvents, which indicates that the energy loss is less between the excitation and fluorescence states. The
... Show More