Preferred Language
Articles
/
oBdzMI8BVTCNdQwCYl8H
Surface assessment of CNC laser treated commercially pure Titanium and Ti 13 Zr 13 Nb alloy
...Show More Authors

This study aimed to evaluate the surface changes of commercial pure Titanium disks (CP Ti) and the Ti 13Nb 13 Zr (Alloy) with a zigzag pattern of laser surface treatment. In vitro, experimental study of CNC Laser treatment on the CP Ti and Alloy disks. Texturing the surfaces of CP Ti and Alloy disks via CNC laser, the sample disks were analyzed using surface roughness, wettability and FESEM. The FESEM revealed a proper increase in the surface texturing and roughness on macro and micro measures without crack formation or dramatic change of the core substance of the CP Ti and Alloy disks. The CNC laser is an effective and suitable method for surface texturing CP Ti and Alloy for dental implantology. Keywords: Commercial pure Titanium; Ti 13 Zr 13 Nb alloy; CNC Laser; Laser surface texturing; Dental implant and surface roughness

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Sep 01 2018
Journal Name
Water Resources
Carcinogenic Risk Assessment of Trihalomethanes in Major Drinking Water Sources of Baghdad City
...Show More Authors

View Publication
Scopus (17)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Wed Nov 01 2023
Journal Name
Ecological Engineering & Environmental Technology
Synthesis of Mn-Co-Ni Composite Electrode by Anodic and Cathodic Electrodeposition for Indirect Electro-oxidation of Phenol – Optimization of the Removal by Response Surface Methodology
...Show More Authors

In the present work, Response Surface Methodology (RSM) was utilized to optimize process variables and find the best circumstances for indirect electrochemical oxidation of mimicked wastewater to remove phenol contaminants using prepared ternary composite electrode. The electrodeposition process is used for the synthesis of a ternary composite electrode of Mn, Co, and Ni oxides. The selected concentrations of metal salts of these elements were 0.05, 0.1, and 1.5 M, with constant molar ratio, current density, and electrolysis time of 1:1:1, 25 mA/cm2, and 2 h. Interestedly, the gathered Mn-Co-Ni oxides were deposited at both the anode and cathode. X-ray diffraction (XRD) and scanning electron microscopy (SEM) facilitated the qualitative char

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Wed May 17 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Mathematical Model of Effect of Number of Pulses of Pulsed Laser on Formation Process of Plasma
...Show More Authors

The effect of number of pulses of pulsed laser on materials is studied analytically, different pulses has been used with the same delay time.  The depth of possible damage to the surface of copper and titanium as well as depth of the crater to both materials were considered in this study.  The study revealed that linear model is only possible when estimating depth of possible damage for copper material, this means that the depth of possible damage increases with the increment of number of laser pulses .As for titanium material, it is found  the relationship is nonlinear.  The depth of possible damage of titanium and copper is not the same, and copper seems to be more predictable than titanium.  
 

View Publication Preview PDF
Publication Date
Wed Mar 28 2018
Journal Name
Iraqi Journal Of Science
Entrance Surface Dose for patient`s undergoing X-ray examinations at Sebha medical center "Libya"
...Show More Authors

Diagnostic X-ray is one of the ionizing radiation that plays an important role in medical examination. Despite its great benefit, it is considered the largest source of artificial radiation exposure to public. The aim of the study is to measure the entrance surface dose (ESD) of patients undergoing chest, lumber spine and knee X-ray examination using TLD-100. The mean Entrance surface dose of chest (PA), lumber spine (AP, LAT) and knee (AP, LAT) are 1.3mGy, 8.57mGy, 21.5mGy and 0.49mGy, 0.48mGy respectively. The ESDs measured were found to be higher than the published work.

View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Baghdad Science Journal
Ammonia Removal in Free-Surface Constructed Wetlands Employing Synthetic Floating Islands: Employing synthetic floating islands
...Show More Authors

Free water surface constructed wetlands (FSCWs) can be used to complement conventional waste water treatment but removal efficiencies are often limited by a high ratio of water volume to biofilm surface area (i.e. high water depth). Floating treatment wetlands (FTWs) consist of floating matrices which can enhance the surface area available for the development of fixed microbial biofilms and provide a platform for plant growth (which can remove pollutants by uptake).  In this study the potential of FTWs for ammoniacal nitrogen (AN) removal was evaluated using experimental mesocosms operated under steady-state flow conditions with ten different treatments (two water depths, two levels of FTW mat coverage, two different plant densities and

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Mon Sep 06 2021
Journal Name
Journal Of Mechanical Engineering Research And Developments
Using Micro-Ceramic as an Abrasive Material to Remove Surface Roughness by Magnetic Abrasive Finishing
...Show More Authors

Due to the rapid advancement of technology and the technology of things, modern industries start to need a highprecision equipment and surface finishing, so many finishing processes began to develop. One of the modern processes is Magnetic Abrasive Finishing (MAF), which is a high-precision process for internal and external finishing under the influence of a magnetic field of abrasive particles. Boron Carbide (B4C) ceramics was tested by mixing it with iron (Fe) and produced abrasive particles to reduce the intensity of scraping on the surface, reduce the economic cost and achieve a high finishing addition to remove the edges at the same time. The material selected for the samples was mild steel (ASTM E415) under (Quantity of Abrasives, Mac

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Iraqi Journal Of Physics
Surface Plasmon Resonance (SPR)-Based Multimode Optical Fiber Sensors for Electrical Transformer Oil Aging Detection
...Show More Authors

I

In this study, optical fibers were designed and implemented as a chemical sensor based on surface plasmon resonance (SPR) to estimate the age of the oil used in electrical transformers. The study depends on the refractive indices of the oil. The sensor was created by embedding the center portion of the optical fiber in a resin block, followed by polishing, and tapering to create the optical fiber sensor. The tapering time was 50 min. The multi-mode optical fiber was coated with 60 nm thickness gold metal. The deposition length was 4 cm. The sensor's resonance wavelength was 415 nm. The primary sensor parameters were calculated, including sensitivity (6.25), signal-to-noise ratio (2.38), figure of merit (4.88), and accuracy (3.2)

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Iraqi Journal Of Physics
D-Shaped Photonic Crystal Fiber Toxic Metal Ions (Arsenic) Sensor Based on Surface Plasmon Resonance
...Show More Authors

In this work, a Photonic Crystal Fiber (PCF) sensor based on the Surface Plasmon Resonance (SPR) technology was proposed. A thin layer of gold (Au) was deposited on a D-shaped Photonic Crystal Fiber (PCF), which was coated with plasmonic chemically stable gold material with a thickness of 40nm. The performance parameters like sensitivity including wavelength sensitivity and amplitude sensitivity and resolution were evaluated by simulation using COMSOL software. The proposed sensor was created by using the finite element approach, it is numerically examined. The results show that the surface of D-shaped Photonic Crystal Fiber coated with Au behaves as a sensor to detect the refractive index (IR) of toxic metal ions. The impacts of the str

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Cysts and Cystic-Like Lesions of the Jaws and Their Effect on Adjacent Structures by Using Cone Beam Computed Tomography (CBCT)
...Show More Authors

Background: Preoperative radiographical assessment of the maxillofacial lesions is of a great importance in guiding the surgeon during surgical procedure in reducing post-operative complications. This study highlighted the application of CBCT scan in the assessment of maxillofacial cystic and cystic like lesions as a part of advanced radiology Materials and methods: A total of 20 patients (15 males and 5 females) participated in this prospective study. CBCT scan (Kodak 9500 CBCT) with (DICOM) software utilized to perform scanning to all patients in order to assess lesion extension, morphological features and it’s relation to the adjacent vital structures. Results: In this study, the total cystic and cystic like lesions involving the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 24 2019
Journal Name
Iraqi Journal Of Physics
Laser energy effect on the properties of ZnS thin films prepared by PLD technique
...Show More Authors

Zinc sulfide (ZnS) thin films were deposited on glass substrates using pulsed laser deposition technique. The laser used is the Q-switched Nd: YAG laser with 1064nm wavelength and 1Hz pulse repetition rate and varying laser energy 700mJ-1000mJ with 25 pulse. The substrate temperature was kept constant at 100°C. The structural, morphological and optical properties of ZnS thin films were characterized with X-ray diffraction (XRD), scanning electron microscopy (SEM), atomic force microscope (AFM) and UV-VIS spectrophotometer.

View Publication Preview PDF
Crossref (1)
Crossref